§ 30-494 — Commercial and mixed-use development standards
Code of the City of Fontana, California (Supp. No. 65: codified through Ordinance No. 1987, enacted April 28, 2026) · Fontana Zoning and Development Code § 30-494
Corpus is an independent public-information project, not the official City of Fontana website. Stable reference: corpuslaw.us/code/222b8bc5-a573-4ab7-a338-4e5744bfa3d4
Sec. 30-494. - Commercial and mixed-use development standards.
(a) [Minimum standards.] The development standards outlined in this section are the minimum standards applicable to the development of commercial and mixed-use structures. (b) Lot dimensions, building height, and maximum intensity. Table No. 30-494.A, specifies required lot dimensions, height limitations, and maximum permitted building intensities. The lot dimension requirements apply only to the creation of new parcels. Also, the lot dimension requirements do not apply to commercial and mixed-use development over five acres in lot area that provides for reciprocal access, parking, and maintenance. Table No. 30-494.A Lot Dimensions, Building Height, and Maximum Intensity Feature | C-1 | C-2 | RMU Lot size Minimum | 20,000 sf | 40,000 sf | 1 acre Maximum | none | none | none Lot dimensions Minimum Width | 100-foot | 150-foot | none Minimum Depth | 100-foot | 200-foot | none Maximum Building Heights | 35-foot | 60-foot | 75-foot Lot Coverage (percent) | 50% | 50% | none Maximum FAR | 0.50 | 1.0 | 1.0 (d) In calculating the FAR for mixed-use projects, only 50 percent of the area devoted to residential and accessory uses shall be included in the calculation. (c) Landscape areas—Setbacks. Tables No. 30-494.A, and Tables No. 30-494.B, specify the minimum required setbacks for buildings and parking areas. All required yard areas shall be clear of all structures and shall be landscaped and maintained in a neat and healthy condition according to the landscaping provisions of this title. Table No. 30-494.B Minimum Required Setbacks for Buildings Building Setbacks | C-1 | C-2 | RMU Abutting freeways | 25-foot | 25-foot | 25-foot Abutting major highways | 20-foot (a) | 20-foot | 20-foot Abutting primary highways | 20-foot (a) | 20-foot | 20-foot Abutting secondary or collector streets | 15-foot (a) | 15-foot | 15-foot Abutting local streets | 15-foot (a) | 15-foot | 15-foot Side and Rear Setbacks | C-1 | C-2 | RMU Abutting Freeways | 25-foot | 25-foot | 25-foot Abutting residential zone | 20-foot | 20-foot | 20-foot Abutting all other zones | 0 | 0 | 0 (1) For properties along the same block face as properties zoned for residential use, the setback shall be the same as established for the residential uses. (2) An additional setback may be required by the Director of Community Development. Table 30-494.C Minimum Required Setbacks for Parking Areas Parking Area and Drive Aisle Setbacks | C-1 | C-2 | RMU Abutting Freeways | 25-foot | 25-foot | 25-foot Abutting Major Highways | 20-foot | 20-foot | 20-foot Abutting Primary Highways | 20-foot | 20-foot | 20-foot Abutting Secondary, Or Collector Street | 15-foot | 15-foot | 15-foot Abutting Local Street | 15-foot | 15-foot | 15-foot Side and Rear Setbacks | C-1 | C-2 | RMU Abutting freeways | 25-foot | 25-foot | 25-foot Abutting residential zone | 10-foot | 10-foot | 10-foot Abutting all other yard areas | 0-foot | 0-foot | 0-foot (d) Permitted uses in required yard areas. The accessory uses and structures permitted in yard areas shall be limited as follows: (1) Street yard areas. Landscaping, on-premises signs, and pedestrian walkways. (2) Rear yards, interior side yards, yards abutting alleys. Landscaping, pedestrian walkways, and similar accessory uses. (e) Permitted projections into yard areas. No projections may extend into required yard areas except as follows: (1) Signs, as specified in Chapter 3 of the Municipal Code. (2) Awnings, eaves, canopies, roof projections, and similar architectural features for a distance of five feet, provided the feature is located at least eight feet above grade and no closer than five feet from the property line. (3) Bay windows, chimneys, fireplaces, balconies, and similar features for a distance of three feet, provided the feature is located no closer than five feet from the property line. (4) Theater marquees for a distance of eight feet or no nearer than two feet to the face of an existing curb, whichever is less. (5) Balconies for residential units within a mixed-use project for a distance of six feet into a required yard facing a street. (f) Landscaping requirements. All required street setbacks shall be landscaped in accordance with provisions in Article X. In no event shall the off-street parking encroach within such setback area. (g) Screening required. (1) General. The following required screening shall apply in all commercial and mixed-use zoning district: a. Outdoor storage. Outdoor storage shall be prohibited. b. Parking lots. All parking lots shall be screened as provided for in Article XI of this chapter. c. Adjacent to residential districts. All commercial and mixed uses adjoining or abutting a residential district shall be screened by a solid masonry wall not less than six feet but no higher than eight feet in height. However, in the front yard area abutting the residential lot, the wall may be lower as determined through the design review process. d. Trash, utility and loading areas. Trash enclosures, utility areas, loading areas and the like shall be screened by walls, earthen berms, landscaping, buildings, or any combination of these features. (2) Mechanical equipment of building sides and rooftops. The following restrictions shall apply to all roof-mounted mechanical equipment: a. Required. In all commercial and mixed-use zoning districts, rooftop mechanical equipment, except solar collectors and rain gutters, shall be screened on all sides by screening not less than the height of the equipment being screened. b. Secured. All rooftop mechanical equipment shall be secured from unauthorized entry to the satisfaction of the Building Official. c. Materials. All rooftop mechanical equipment screening devices shall be of a material requiring a low degree of maintenance. All screening devices shall be well integrated into the design of the building through such items as parapet walls continuous with the walls of the structure, false roofs, or equipment rooms.
(Ord. No. 1823, § 8(Exh. A), 2-25-20)
Ask a question about Fontana law
Corpus searches the Fontana sections it holds and shows the ones that match, with their citations. Free, no sign-in.
