For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 30-508 — Site plan design

Code of the City of Fontana, California (Supp. No. 65: codified through Ordinance No. 1987, enacted April 28, 2026) · Fontana Zoning and Development Code § 30-508

Corpus is an independent public-information project, not the official City of Fontana website. Stable reference: corpuslaw.us/code/b23380e6-03b4-4f8f-aa59-9936018290f1

Sec. 30-508. - Site plan design.

(a) Grading and drainage. (1) Graded slopes shall meet Uniform Building Code and the City Engineer's standards. (2) All graded slopes in excess of three to one shall be stabilized and planted with groundcovers and trees or shrubs. (3) The grading of land along transportation corridors shall conform to the natural topography of the immediate area and result in a harmonious transition of the manmade grade with the natural terrain. (4) Site grading design shall complement and reinforce the architectural and landscape design character by helping to screen parking, loading and service areas, by helping to reduce the perception of height and mass on large buildings, by providing reasonable transitions between on-site uses, by providing elevation transitions contributing to the efficiency of on-site and off-site movement systems, and by providing reasonable transition between lots. (5) All three-to-one slopes or greater shall require an erosion control management plan. (b) Building orientation. (1) All buildings shall be located and oriented to reduce noise, light and glare, visual, and other conflicts. Refuse collection and loading areas shall be located in areas where noise from such operations will not adversely impact adjacent residential uses. (2) Buildings shall be located for windows and entries to take advantage of scenic views where possible. (3) Buildings shall be designed and located to minimize the impact of built forms on the natural landscape. Rooflines shall keep a low profile so as to not dominate the horizon line. (4) The orientation of a building and its parts shall be related to nature and the elements: sun, wind and rain. The design and placements of windows and doors shall be considered with exposure to natural elements in mind. (5) In new projects, buildings shall be positioned to minimize the impact of shadows on adjacent properties. Building architecture shall be designed to provide shade in the summer and sunlight in the winter. (6) Placement of the commercial and mixed-use buildings shall provide the most aesthetic public views. (7) All design shall appear as an integrated part of an overall design theme. (8) Building setbacks from the street shall vary to provide character to the area. (9) All HVAC ducts shall be oriented away from adjoining and on-site residential property. (10) A majority of the primary living spaces within the residential portion of a mixed-use project should receive direct sunlight for the daylight hours. (c) Access and circulation. (1) Pedestrian. a. On-site pedestrian circulation systems shall be provided to meet the movement needs of on-site users. Such systems shall provide safe, all-weather surfaces and aesthetically pleasing means of on-site foot travel. Pedestrian walkways shall be an integrated part of the overall architecture and site design concept. b. Pedestrian and bicycle access shall be conveniently provided to connect surrounding land uses and commercial or mixed uses. c. All new commercial and mixed-use development shall be accessible to persons with disabilities as required elsewhere in this chapter. d. All primary ground-floor common entries and individual dwelling unit entries for mixed-use projects fronting on streets should be oriented to the street, not to the interior or to a parking lot. e. On-site pedestrian circulation for mixed-use projects should be continuous and connect various uses on site, as well as connect to off-site transit stops and parking. (2) Vehicular. a. Bus turnouts shall be installed in commercial and mixed-use areas that generate the highest bus passenger volume. Mass transit routes that serve areas of commercial and mixed uses shall load passengers in clearly marked, reserved areas with pedestrian facilities provided. b. The access and circulation of a development shall be designed to provide a safe and efficient system, both on and off the site. Points of access shall be designed in conformance with the City access regulations and shall not conflict with other planned or existing access points. c. Access drives for commercial and residential areas shall be located as far as possible from street intersection and shall be coordinated with median openings and where median openings are not available, designed for efficient "right-turn only" ingress and egress. d. Access drives shall be coordinated with adjacent lots so as to minimize the number of curb cuts required and to not impede on the efficient flow of peak period traffic. Consideration shall be given to adequate separation of adjacent access drives or the development of common access drives. e. In no case should trucks have to use public right-of-way to maneuver into a loading space, including the necessity to have to back in from a public right-of-way. There shall be adequate truck maneuvering area for the truck size anticipated for the commercial development. Trucks utilizing loading areas shall not encroach upon drive aisles or parking spaces. (d) Relationship of parking areas and loading zones to buildings. (1) Parking areas shall not be the dominant element in the overall design of a project and shall be designed to minimize visual disruption. Multi-user parking areas shared between buildings and uses shall be encouraged to the maximum extent possible. (2) Aisles should be positioned whenever possible perpendicular to building entries for easy pedestrian access. Pedestrian corridors shall also incorporate landscaping material. (3) Driveway access to rear parking areas and clear signage identifying rear parking availability shall be provided. (e) Open space. The following standards are applicable for commercial and mixed-use development greater than ten acres in size. (1) Open spaces shall be designed as an integral part of the overall site plan design. Open spaces shall enhance the building design, enhance public views and spaces, provide buffers and transitions, provide for a balance of solar uses, and provide screening. (2) The display of art and fountains is encouraged in public open spaces. (3) Open spaces can occur within a commercial or mixed-use development in any scale, from an intimate seat wall to an expansive celebratory plaza. These spaces are encouraged within all new commercial and mixed-use development and shall be designed at a scale proportionate to each individual project. (4) Designed open spaces shall promote "people gathering," provide seating areas, and bring the architecture down to a human scale. These spaces shall stand out visually as desirable, active, and functional spaces and shall be typically characterized in the form of plazas, courtyards, auto drop-off zones, promenades and outdoor and sidewalk eating areas. (5) Open spaces shall provide a strong landscape design and access connection to the primary building entry. (6) Open spaces shall be integrated into the vehicular and pedestrian circulation systems as a primary focus and destination. (7) Open spaces shall be strongly defined by adjacent buildings with facades being visually interesting and building mass well-articulated. (8) The provision of ample seating in open spaces areas is essential and should be carefully places to allow a variety of sitting environments and opportunities for people watching. (9) Open space for the residential portions of mixed-use projects shall comply with the following provisions: a. Residents shall have access to useable open space, whether public or private, for recreation and social activities. The design and orientation of these areas shall take advantage of available sunlight and shall be sheltered from the noise and traffic of adjacent streets or other incompatible uses. b. In projects where, common open space is required, the space shall be located conveniently for the majority of units. c. Private open space areas shall be contiguous to the units they serve, screened from public view and be of a useable size (for example, big enough to accommodate a patio table and four chairs or a patio and gardening area). d. Children's play areas shall be visible from dwelling units. (f) Lighting. (1) All exterior lighting shall be adequately controlled and shielded to prevent glare and undesirable illumination to adjacent properties or streets. (2) On-site lights shall provide a safe, functional and aesthetic design. Enough lighting should be provided to ensure a safe environment while at the same time not cause areas of intense light or glare. (3) Light fixtures and poles shall be designed and placed in a manner consistent and compatible with the overall site and building design. (4) Shall comply with Fontana Police Department security requirements. (5) Security lighting shall be utilized in all parking areas and pedestrian walkways within the residential portions of mixed-use projects. (g) Utilities. (1) Temporary overhead power and telephone facilities are permitted only during construction. (2) Placement, location and screening of utilities of any kind which cannot be installed underground and must be placed above ground for function and safety reasons require approval by the Director of Planning. (3) Transformer enclosures shall be designed of durable materials with finishes and colors used which are compatible and harmonious with the overall architectural theme. (h) Public safety. (1) Entrances to buildings shall be well lighted and void of any large shrubbery or obstructions. (2) Adequate emergency access routes for the egress/ingress of emergency vehicles shall be required for all projects. Where space for a separate vehicle access road is difficult, a portion of a greenbelt or open space area shall be lined with "turf block" to allow heavy equipment to access structures. (3) A fuel modification zone shall be required in areas threatened by fire hazard. (4) The residential units in a mixed-use project shall be designed to ensure the security of residents through the provision of secured entrances and exits that are separate from the non-residential uses. Non-residential and residential uses shall not have common entrance hallways or common balconies.

(Ord. No. 1970, § 4(Exh. A), 6-10-25)

Ask a question about Fontana law

Corpus searches the Fontana sections it holds and shows the ones that match, with their citations. Free, no sign-in.