§ 30-550 — Site plan design
Code of the City of Fontana, California (Supp. No. 65: codified through Ordinance No. 1987, enacted April 28, 2026) · Fontana Zoning and Development Code § 30-550
Corpus is an independent public-information project, not the official City of Fontana website. Stable reference: corpuslaw.us/code/64c71996-6015-4ceb-8e35-220513a88f50
Sec. 30-550. - Site plan design.
(a) Grading and drainage. (1) Graded slopes shall meet California Building Code. (2) All graded slopes in excess of three to one shall be stabilized and planted with groundcovers and trees or shrubs. (3) Grading shall not occur within the drip line of a tree (with a caliper size greater than ten inches at chest height) that merits observation or within ten feet of the bank of a riparian corridor unless such grading is approved by a landscape architect. (4) The grading of land along transportation corridors shall conform to the natural topography of the immediate area and result in a harmonious transition of the manmade grade with the natural terrain. (5) Site grading design shall complement and reinforce the architectural and landscape design character by helping to screen parking, loading and service areas, by helping to reduce the perception of height and mass on large buildings, by providing reasonable transitions between on-site uses, by providing elevation transitions contributing to the efficiency of on-site and off-site movement systems, and by providing reasonable transition between lots. (b) Building orientation. (1) All buildings shall be cited and oriented to reduce noise, light and glare, visual, and other conflicts. Refuse/recycle collection and loading areas shall be located in areas where noise from such operations will not adversely impact adjacent residential uses. (2) Buildings shall be cited for windows and entries to take advantage of views. (3) Buildings shall be designed and cited to minimize the impact of built forms on the natural landscape. Roof lines shall keep a low profile so as to not dominate the horizon line. (4) The orientation of a building and its parts shall be related to nature and the elements: sun, wind, and rain. The design and placements of windows and doors shall be considered with exposure to natural elements in mind. (5) In new projects, buildings shall be positioned to minimize the impact of shadows on adjacent properties. Building architecture shall be designed to provide shade in the summer and sunlight in the winter. (6) Placement of the industrial buildings shall provide the most aesthetic public views. Open work areas shall be located away from public views. Where overriding considerations require that the work areas remain visible to public views, they must be fully screened using walls and a combinations of berms and landscaping. (7) Design themes for individual projects shall integrate the constraints and opportunities provided by adjacent developments in complying with an overall street design theme. (8) Building area setbacks from the street shall vary to provide character to the area. (9) Whenever possible, buildings should be oriented on the site in a manner that will allow for solar energy devices to have access to sunlight. Running roof ridge lines east-west allows easy solar access for roof mounted solar collectors. (10) HVAC ducts shall be oriented away from abutting residential areas. (c) Access and circulation. (1) Pedestrian. a. On-site pedestrian circulation systems shall be provided to meet the movement needs of on-site users. Such systems shall provide safe, all-weather surfaces and aesthetically pleasing means of on-site foot travel. Pedestrian walkways shall be an integrated part of the overall architecture and site design concept. b. Pedestrian and bicycle access shall be conveniently provided to connect industrial uses with surrounding land uses. c. Along walkways, between buildings, expanded areas provide for occasional sitting areas are encouraged. (2) Vehicular. a. On site bus turnouts and shelters shall be installed in industrial areas that generate the highest bus passenger volume. Mass transit routes that serve areas of business use shall load passengers in clearly marked, reserved areas with pedestrian facilities provided. b. The access and circulation of a development shall be designed to provide safe and efficient system, both on and off the site. Points of access shall be designed in conformance with the City access regulations, and shall not conflict with other planned or existing access points. c. The vehicular circulation system shall be designed to reduce conflicts with pedestrian traffic, minimize impacts on adjacent properties, combine circulation and access areas where possible, and provide adequate maneuvering areas. d. Access drives for industrial areas shall be located as far as possible from street intersections and shall be coordinated with median openings and where median openings are not available, designed for efficient "right-turn only" ingress and egress. e. Access drives shall be coordinated with adjacent lots so as to minimize the number of curb cuts required and to not impede on the efficient flow of peak period traffic. Consideration shall be given to adequate separation of adjacent access drives or the development of common access drives. f. In no case should trucks have to use public right-of-way to maneuver into a loading space, including the necessity to have to back-in from a public right-of-way. There shall be adequate truck maneuvering area for the largest truck size anticipated for the subject industrial development. Trucks utilizing loading areas shall not encroach upon drive aisles or parking spaces. Sufficient area shall be provided for the parking of empty or stored trailers. g. The citing of handicap parking stalls within an industrial development shall be subject to the requirements of the current Building Code. (d) Relationship of parking areas to buildings. (1) Adequate parking shall be provided for all new industrial facilities to accommodate peak hour use. See Article XI for standards. The employees and visitors parking shall be located separate from truck loading areas. (2) Aisles shall be positioned perpendicular to building entries for easy pedestrian access. Pedestrian corridors shall also incorporate landscaping material. (3) Where design permits, parking areas located behind buildings are encouraged. Driveway access to rear parking and loading areas and clear signage identifying rear parking availability shall be incorporated into the overall design. (4) If vehicle parking is adjacent to the on-site truck path, the vehicle parking shall be located on the building side of the truck path. (e) Open space. (1) Open spaces shall be designed as an integral part of the overall site plan design. Open spaces shall enhance the building design, enhance public views and spaces, provide buffers and transitions, provide for a balance of solar uses, and provide screening. (2) The display of art and fountains is encouraged in open spaces. (3) Open spaces can occur within an industrial development in any scale, from an intimate low wall for sitting to an expansive plaza. These spaces are encouraged within all new industrial development and shall be designed at a scale proportionate to each individual project. (4) Open spaces shall provide a landscape design and access connection to the primary building entry. (5) Open spaces shall be integrated into the vehicular and pedestrian circulation systems as a primary focus and destination. (6) Open spaces shall be strongly defined by adjacent buildings with facades being visually interesting and building mass well-articulated. (7) The provision of ample seating/outdoor break area in open space areas is essential and should be carefully placed to allow a variety sitting environments. (8) Open spaces shall be designed to direct attention toward the entry statement of the project. (f) Lighting. (1) All exterior lighting shall be adequately controlled and shielded to prevent glare and undesirable illumination to adjacent properties or streets. (2) On-site lights shall provide a safe, functional and aesthetic design. Enough lighting should be provided to ensure a safe environment while at the same time not cause areas of intense light or glare. (3) Light fixtures and poles shall be designed and placed in a manner consistent and compatible with the overall site and building design. (4) High intensity security lighting fixtures shall not be substituted for site or landscape lighting or general building exterior illumination, but shall be limited to loading and storage locations or other similar service areas only. (g) Utilities. (1) Temporary overhead power and telephone facilities are permitted only during construction. (2) Transformer enclosures shall be designed of durable materials with finishes and colors used which are compatible and harmonious with the overall architectural theme. (3) Placement, location and screening of utilities of any kind which cannot be installed underground and must be placed above ground for function and safety reasons require approval by the Director of Planning. (h) Public safety. (1) Entrances to buildings shall be well lighted and void of any large shrubbery or obstructions. (2) Adequate emergency access routes for the egress/ingress of emergency vehicles shall be required for all projects.
(Ord. No. 1865, § 8(Att. 2), 3-23-21; Ord. No. 1970, § 4(Exh. A), 6-10-25)
Ask a question about Fontana law
Corpus searches the Fontana sections it holds and shows the ones that match, with their citations. Free, no sign-in.