For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 30-655 — General development standards and design guidelines

Code of the City of Fontana, California (Supp. No. 65: codified through Ordinance No. 1987, enacted April 28, 2026) · Fontana Zoning and Development Code § 30-655

Corpus is an independent public-information project, not the official City of Fontana website. Stable reference: corpuslaw.us/code/6afbdadc-0e06-4d38-90bc-b921845b0f21

Sec. 30-655. - General development standards and design guidelines.

(a) General. The development standards and design guidelines in this division shall be minimum requirements for emergency shelters, supportive and transitional housing type uses. Those standards and guidelines not fully addressed in this section shall be as otherwise stated in the appropriate section(s) of the Fontana Municipal Code, including, but not limited to, Section 30-664 et seq., and Section 30-679 et seq. of this Code. Table 30-655.A. Lot Dimensions, Building Height and Maximum Intensity Feature | Standard Minimum lot size | The minimum lot size shall be 20,000 square feet Lot dimensions | Minimum width of 150 feet Minimum depth of 150 feet Maximum building height | The maximum building height shall be 100 feet Maximum lot coverage | The maximum lot coverage shall be 60% Floor-area ratio (FAR) | The maximum base FAR shall be 0.50 (b) Building setbacks. All required yard areas (setbacks) shall be clear of all structures and other required site features such as parking areas, loading areas, fire lanes, etc., and shall be landscaped and maintained in a neat, healthy, aesthetically pleasing condition in accordance with the landscaping provisions of this division. Setback may be increased to provide an appropriate separation between uses in order to protect the public health, safety, and welfare if alternative means of providing separation are not practical. Table 30-655.B Yard Area-Building Setbacks Yard | Standard Minimum front yard setbacks | 25 feet Minimum rear yard setbacks | 25 feet Minimum interior side yard setbacks | 15 feet Minimum corner/street side yard setback | 15 feet (c) Parking and loading requirements. Off-street parking shall be located at the rear or side of the building, but may be considered elsewhere at the discretion of the Director of Community Development. Visitor parking may be located at the front of the building adjacent to the main entry. Service and loading areas may be located at the sides and rear of the building, except where such building sides are adjacent to a public right-of-way. (d) Parking. The following are regulations for off-street parking and loading. They identify required number of parking and loading spaces for all new development projects and those proposing substantial modifications to existing buildings. For all parking and loading-related information or regulations not specifically addressed in this section, refer to Section 30-679 et seq. of this Code. Table 30-655.C Minimum Number of Parking Spaces Required Use | Facility Parking | Staff Parking | Guest Parking | Bike Rack | Loading Spaces Emergency Shelter | 1 space per five beds | 1 space per employee | 1 space per ten beds | 5 spaces | 1 Truck space Supportive Housing | 1 space per room, family or resident | 1 space per employee | 1 space per three room, family or resident | 5 spaces | 1 Van space Transitional Housing | 1 space per room, family or resident | 1 space per employee | 1 space per three room, family or resident | 5 spaces | 1 Van space (1) Parking and access. a. Parking lots shall not be the dominant visual element on the site. b. Surface parking areas shall integrate trees and landscape improvements to reduce the heat island effect and to promote better visual aesthetics. c. Parking lot design shall include water quality storm water facilities consistent with City standards. See Figure 1. Figure 1 [image omitted; see the official code] (e) Fences, walls, and screening. The following are standards and guidelines for fences, walls, and screening. Table 30-655.D Standards for Fences, Walls and Screening Location | Materials | Maximum Height Within front setback area | Solid wall | 42 inches Wrought iron or tubular steel | 6 ft. Within street side setback area | Solid wall | 8 ft. Within interior side setback area | Solid wall | 8 ft. Within rear setback area | Solid wall | 8 ft. Screening of incidental outdoor storage from view of the public right-of-way | Solid wall | 8 ft. Notes: (1) All fences and walls shall be finished with decorative material (e.g., stucco, split-face, and or slump stone) when visible from the public right-of-way. (2) All fences and walls shall not interfere with or obstruct the line-of-sight for motorists. (3) Screening walls must meet the design standards of Section (n)(3)(a). (1) Fences and walls. a. Walls and fencing materials shall consist of wrought iron, tubular steel, stone, stucco, or brick, and shall be compatible with the overall design character/style of the development. The use of chain-link fence and similar materials is prohibited. b. Walls and fences shall be integrated with landscaping along the base of the wall or fence. c. Wall heights and surfaces shall be articulated with varying facade depths or pilasters to promote architectural interest, and shall include a cap along the top of the wall. d. Landscaping shall be used in combination with walls and fences to visually soften blank surfaces and to deter graffiti. Additionally, all walls shall have an anti-graffiti coating to further deter graffiti, to the satisfaction of the City. See Figure 2. Figure 2 [image omitted; see the official code] (f) Landscaping. Those standards and guidelines not fully addressed in this section shall be as otherwise stated in the appropriate section(s) of the Fontana Municipal Code, including, but not limited to, Section 30-664 et seq., of this Code. (1) Landscaping shall be used alone or in conjunction with other features (e.g. open space buffer, topography) to reduce potential visual and light and glare conflicts. (2) Landscape setbacks along public rights-of-way shall incorporate landscape buffers with undulating and variable height earth-mounding (berms), and/or low walls, preferably in a three-tier planting design. (3) Landscaping shall be in scale with adjacent structures, streets, and public spaces, and be sized appropriately when fully grown. (4) Landscaped areas should incorporate a three-tiered planting system: a. Ground cover and flowering plants; b. Shrubs and vines; and, c. Trees. (g) Site design. (1) Courtyards and plazas. a. Buildings should be arranged to create opportunities for open space amenities (e.g., plazas, courtyards, outdoor eating areas, etc.). (2) Building orientation. a. The organization of buildings, parking areas, and landscaping shall recognize the existing characteristics of the site and shall relate to the surrounding development in scale and character. b. Buildings should be oriented in a manner that takes advantage of passive solar design. c. Buildings shall be oriented to provide a buffer between sensitive uses (i.e. residential, schools, and parks). (3) Site elements. a. Screening. 1. Loading areas shall be completely screened from public right-of-way(s) by building placement and/or decorative walls. Landscaping may be used in addition to such building placement and/or walls, but shall not be the sole means of screening. A sight-line analysis shall be taken from public right-of-way(s) to indicate screening of all items. 2. Trash storage enclosures and outdoor mechanical equipment shall be completely screened from public view. 3. Roof-mounted and ground-mounted mechanical equipment utilities, storage, and storage areas shall be screened from public right-of-way by a visual barrier (e.g., wall, fence, landscape material, parapet walls etc.) or other approved screening devices. Special consideration shall be given to the screening of roof-mounted equipment on building rooftops that are visible from the public right-of-way. See Figure 3. Figure 3 [image omitted; see the official code] (4) Lighting. a. Outdoor lighting plans shall take into consideration the location and potential growth pattern of nearby trees (existing and planned) so that appropriate lighting levels are maintained over time. b. Energy efficiency shall be considered through use of proper light location and placement, as well as use of energy-efficient bulbs and/or fixtures. c. Lighting fixtures shall include hoods or other design techniques to reduce glare and light pollution, especially along major streets, and to prevent light spillover onto adjacent properties. d. Lighting shall be provided in project entryways, walkways, and parking lots to promote safety. e. Lighting may be mounted on poles or bollards, affixed to building walls, or placed within paved or landscaped areas. Appropriate materials and construction methods shall be used to ensure proper function of project lighting fixtures. f. Decorative light fixtures shall be consistent with the architectural design of the building. (5) Architecture. a. Mass and scale. 1. The mass and scale of the buildings shall respect the visual and physical relationship to the adjacent buildings and surrounding sensitive uses. Taller building elements shall be placed towards the center of the site, with lower elements adjacent to surrounding properties. 2. Buildings shall be stepped back when adjacent to or in close proximity to sensitive uses (e.g. residential, schools, etc.). 3. Vertical and horizontal offsets shall be provided to reduce the visual bulk of the building. b. Building facades. 1. Building facades shall incorporate architectural elements such as windows, pillars, and wall plane breaks to minimize blank walls, to create visual interest, and to reduce the opportunity for graffiti. 2. All building elevations, whether front, side, or rear shall be architecturally detailed. 3. Architectural accents (e.g., cornices, tiles, trim around windows, grooves in building faces, accent band details, bulkheads, etc.) shall be used to create variation along building facades. 4. Roofs shall be designed as an integral component of building form, mass, and facade. Building form shall be enhanced by sloped or offset roof planes, eave heights, and rooflines.

(Ord. No. 1708, Exh. A, § 6, 10-28-14; Ord. No. 1865, § 8(Att. 2), 3-23-21)

Ask a question about Fontana law

Corpus searches the Fontana sections it holds and shows the ones that match, with their citations. Free, no sign-in.