For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 30-734 — Sign illumination, neon tubing, and electronic message signs

Code of the City of Fontana, California (Supp. No. 65: codified through Ordinance No. 1987, enacted April 28, 2026) · Fontana Zoning and Development Code § 30-734

Corpus is an independent public-information project, not the official City of Fontana website. Stable reference: corpuslaw.us/code/f5b19de4-4060-4fd9-b88b-7b1a104c4d16

Sec. 30-734. - Sign illumination, neon tubing, and electronic message signs.

(a) General requirements. (1) Illumination method. Sign illumination may be internally or externally illuminated and shall not blink, flash, flutter, or change light intensity, brightness, or color unless consistent with the standards for electronic message signs in Section 30-734. (2) Bulb face exposure. Reflective-type bulbs and incandescent lamps that exceed 15 watts shall not be used on the exterior surface of signs so that the face of the bulb or lamp is exposed to a public right-of-way or adjacent property. This provision does not apply to light-emitting diodes (LEDs) associated with electronic message signs. (3) Energy efficiency. Sign illumination shall utilize energy-efficient light sources, such as LEDs, to the greatest extent possible. (4) Shielding—General. Sign illumination shall not interfere with the use and enjoyment of adjacent properties, create a public nuisance, or create public safety hazards. Exterior light sources shall be shielded from view and directed to illuminate only the sign face. (5) Shielding—Residential properties. Sign illumination shall be limited to avoid light projection of an intensity or brightness or directed in a manner that will negatively impact residential properties in direct line of sight to the sign. (b) Neon tubing. (1) Sign types. Neon tubing, including exposed neon tubing, for signs and architectural elements shall only be permitted in commercial zoning districts on canopy signs, marquee signs, and wall signs pursuant to the provisions in this section and Division 6 of this article. Neon tubing shall also be permitted in commercial zoning districts on projecting signs and window signs pursuant to this section and Section 30-721. (2) Standards. Neon tubing, including exposed neon tubing, for signs and architectural elements shall comply with the following standards: a. Neon tubing shall be UL (Underwriters Laboratories) listed with a maximum 20 amps per circuit and be designed to accommodate a dimmer in order to reduce the brightness of the neon; b. The neon manufacturer shall be registered with Underwriters Laboratories; c. Neon tubing shall not exceed one-half inch in diameter; d. Neon lighting adjacent to residential uses shall not exceed one-half foot-candle measured at the property line; and e. Neon tubing shall not be combined with any reflective materials (e.g., mirrors, polished metal, highly glazed tiles, or other similar materials) (c) Electronic message signs. (1) Sign types. Electronic messages shall be permitted on freestanding menu board signs, freeway signs, pylon signs, and theater marquee signs pursuant to the provisions in this section and Division 6 of this article. Electronic messages shall also be permitted on window signs pursuant to this section and Table No. 30-721.A. (2) Display change. Electronic message signs may display changing messages, provided that each message is displayed for no fewer than eight consecutive seconds, and shall not flash, blink, flutter, or display video messages (i.e., any illumination or message that is in motion or appears to be in motion). The transition or blank screen time between one display message and the next shall not exceed one second. (3) Nighttime brightness. a. Nighttime brightness shall be measured with an illuminance meter set to measure foot-candles accurate to at least two decimals. Illuminance shall be measured with the electronic message off, and again with the electronic message displaying a white image for a full color-capable electronic message or a solid message for a single-color electronic message. b. All measurements shall be taken perpendicular to the face of the electronic message at the following distance: [image omitted; see the official code] c. The difference between the off and solid message measurements shall not exceed 0.3 foot-candles at night. (4) Ambient light sensor. Electronic message signs shall be equipped with a sensor or other device that automatically determines the ambient illumination and programmed to automatically dim according to ambient light conditions (e.g., photocell technology), or that can be adjusted to comply with the 0.3 foot-candle requirement. (5) Turn off. Electronic message signs located within 500 feet and in a direct line of sight of a residentially zoned property or a mixed-use property with residential uses shall be turned off daily at the close of business, or at such a time as specified by the Director of Community Development, and in no case shall be permitted to be turned on between the hours of 10:00 p.m. and 6:00 a.m. Direct line of sight shall be measured from any point on the property with residential uses and may be partially, but not wholly, obstructed. (6) Electronic sign certification. The owner of any electronic message sign shall arrange for certification by an independent contractor showing compliance with brightness standards.

(Ord. No. 1868, § 9(Att. 2), 5-25-21)

Ask a question about Fontana law

Corpus searches the Fontana sections it holds and shows the ones that match, with their citations. Free, no sign-in.