For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 30-747 — Permanent signs for specific uses

Code of the City of Fontana, California (Supp. No. 65: codified through Ordinance No. 1987, enacted April 28, 2026) · Fontana Zoning and Development Code § 30-747

Corpus is an independent public-information project, not the official City of Fontana website. Stable reference: corpuslaw.us/code/ef7bbda7-1f5a-4b43-b192-68cf7d424e45

Sec. 30-747. - Permanent signs for specific uses.

This section establishes additional sign types and standards for specific uses. (1) Drive-through establishments. In addition to the signs permitted pursuant to Section 30-743, Section 30-744, and Section 30-745, businesses with drive-through(s) shall be allowed the following sign types and sign areas, subject to design review sign approval. a. Freestanding menu board signs. 1. Number of signs and sign area. Two freestanding menu board signs are permitted for each establishment with a drive-through, each not exceeding 40 square feet (or not to exceed a combined 80 square feet). 2. Height. Freestanding menu board signs shall not exceed eight feet in height. The freestanding menu board sign structure may extend above the sign height limit if: i. The sign structure is separately constructed from the cabinet or face of the sign; ii. The portion above the cabinet or face does not contain any copy; and iii. The extension adds architectural embellishments to the sign. 3. Changeable copy. Menu board signs shall be permitted to use changeable copy (electronic message or manual). 4. Screening. Menu board signs shall be screened from view from public rights-of-way and abutting properties. b. Porte-cochère signs. 1. Number of signs and location. At drive-through establishments, a maximum of two porte-cochère signs shall be permitted on the porte-cochère façades oriented towards a parking lot, street, or driveway, with only one porte-cochère sign permitted on each porte-cochère façade. 2. Sign area. Porte-cochère signs shall not exceed 12 square feet or 75 percent of the surface area of the porte-cochère façade on which it is located, whichever is less. 3. Sign height. Porte-cochère signs shall not extend above 24 inches of the porte-cochère façade for which it is located, as measured from the lowest point on the sign. 4. Vertical clearance. A minimum vertical clearance of 14 feet is required for porte-cochère signs projecting over vehicular passageways. A minimum vertical clearance of eight feet is required for porte-cochère signs projecting over pedestrian passageways. (2) New and used automobile and/or truck dealerships—Monument sign height. For new and used automobile and/or truck dealerships of five acres or more, the maximum sign height of monument signs shall be ten feet. (3) Fueling stations. See also Sections 13470 and 13530 of the Business and Professional Code. In addition to the signs permitted pursuant to Section 30-743, Section 30-744, and Section 30-745, fueling stations shall be allowed the following sign area and sign types subject to design review sign approval and the following regulations: a. Monument/pylon sign—Location. For fueling stations on corner properties, the 100-foot distancing requirement (subsection 30-746(d)(1)a and subsection 30-746(e)(1)a) shall not apply. b. Fueling island signs. Fueling island signs are allowed up to a maximum of two per each fueling island, with each such sign not exceeding four square feet. c. Fueling station canopy signs—Number and location. Three fueling station canopy signs are permitted on fueling station canopy façades oriented towards a parking lot, street, or driveway with only one fueling station canopy sign permitted on each façade. Fueling station canopy signs shall not extend above the eave line of the fueling station canopy. Digital signs are not permitted. d. Fueling station canopy signs—Sign area. Fueling station canopy signs shall not exceed 25 percent of the surface area of the canopy façade on which it is located. Figure No. 30-747.1. [image omitted; see the official code] (4) Theaters. In addition to the signs permitted pursuant to Section 30-743, Section 30-744, and Section 30-745, theaters shall be allowed theater marquee signs subject to design review sign approval and the following regulations: a. Number of signs. Theaters shall be permitted one theater marquee sign per street frontage, exclusive of freeways. b. Location. 1. No theater marquee sign shall cover, wholly or partially, any wall opening. 2. Theater marquee signs may extend above the eave line. 3. Theater marquee signs shall project no more than seven feet from the face of the building wall upon which the sign is mounted. 4. A minimum vertical clearance of at least eight feet from bottom of a theater marquee sign to highest finished grade shall be maintained. 5. Any encroachment into City right-of-way is subject to City Engineer approval and requires an encroachment permit. c. Sign Area. Theater marquee signs shall not exceed 100 square feet in sign area. d. Height. Theater marquee signs shall not exceed 25 feet in height. e. Illumination. Internal and/or external illumination shall be approved by the Director of Community Development. f. Changeable copy. Theater marquee signs shall be permitted to use changeable copy (electronic message or manual). (5) Nonresidential uses within the downtown boundary. In addition to the signs permitted pursuant to Section 30-743, nonresidential uses within the downtown boundary shall be allowed additional sign area according to Table No. 30.747.A and subject to design review sign approval. Table No. 30-747.A. Nonresidential Uses within the Downtown Boundary Sign Type | Maximum Number | Maximum Sign Area | Maximum Sign Height | Additional Requirements a. Floor inlay sign | 1 per tenant entryway | 25 sf | Such signs shall be installed flush with the pavement | Such signs shall not be located within the public right-of-way Downtown core: May be approved in the public right-of-way. Any encroachment into City right-of-way is subject to City Engineer approval and requires an encroachment permit b. Graphic projection sign | 1 per tenant entryway Downtown core: one per frontage | 10 sf Downtown core: 20 sf | A minimum vertical clearance of at least eight feet from the bottom of the device projecting the sign to the highest finished grade shall be maintained | • Graphic projection shall not blink, flash, flutter, or change light intensity, brightness, or color • The illumination source of the projector shall not be exposed to a public right-of-way or adjacent property • Sign projection shall not interfere with the use and enjoyment of adjacent properties, create a public nuisance, or create public safety hazards c. Holiday window signs | For all window areas | 50 percent of window area | N/A | • Does not require permit • For cultural holidays • Limited display between 45 days prior and 15 days after holiday d. Roof sign | 1 per building over 20,000 square feet | Not exceed three square feet for each linear foot of building frontage where the sign is located, or 200 square feet in total, whichever is lesser | The height of the sign can only be a ratio of two feet of width to one foot of height | • The tenant area must be 20,000 square feet or more • The sign may contain the text identifying the local area such as the building, district, City, downtown or street • The design of the sign must be superior or equal to the architecture of the building and immediate area

(Ord. No. 1868, § 9(Att. 2), 5-25-21; Ord. No. 1974, § 4(Exh. A), 9-9-25)

Ask a question about Fontana law

Corpus searches the Fontana sections it holds and shows the ones that match, with their citations. Free, no sign-in.