For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 15.50.060 — Residential burglary security

Fremont Municipal Code (Fremont Municipal Code current through Ordinance 02-2026 passed May 5, 2026 (Code Publishing Company, codepublishing.com, scraped 2026-11-18)) · Fremont Municipal Code § 15.50.060

Corpus is an independent public-information project, not the official City of Fremont website. Stable reference: corpuslaw.us/code/fd5e4f5b-afce-4e0e-b41a-579dd49605e1

15.50.060 Residential burglary security.

(a) Exterior Doors. (1) Exterior doors on dwellings and garages and doors leading from garage areas into private residences and multiple dwelling residences shall comply with UBC Standard No. 10-5, Part 1; doors in pairs shall be tested in pairs. (2) Exterior doors on dwellings and garages and doors leading from garage areas into private residences or multiple dwelling residences shall have a deadlocking latch device with a minimum throw of one-half inch and a deadbolt lock with a cylinder guard, a hardened steel insert and a minimum throw of one inch. This provision shall not apply to vehicular doors. (3) All main and front entry doors shall be one and three-fourths inch in thickness, solid core. Other exterior doors on dwellings and garages shall be not less than one and three-eighths inch in thickness, solid core. Exterior doors one and three-fourths inch in thickness containing solid wood panels not less than nine-sixteenths inch in thickness are a satisfactory alternate to solid core doors specified in this section. (4) Entry Vision. All main or front entry doors to dwelling units shall be arranged so that the occupant has a view of the area immediately outside the door without opening the door. Such view may be provided by a door viewer having a field of view not less than 180 degrees, through windows or through view ports. (5) Hinges which are exposed to the exterior shall be equipped with nonremovable hinge pins or a mechanical interlock to preclude removal of the door from the exterior by removing the hinge pins. (6) In-swinging exterior doors shall have rabbeted jambs. (7) Strike Plate Installation. In wood frame construction, any open space between trimmers and wood door jambs shall be solid shimmed by a single piece extending not less than six inches above and below the strike plate. Strike plates shall be attached to wood with not less than two No. 8 by 2 inch screws. Strike plates, when attached to metal, shall be attached with not less than two No. 8 machine screws. All strike plates of doors in pairs shall be installed as tested. (8) Jambs for all doors shall be constructed or protected so as to prevent violation of the function of the strike from the outside. (9) Light panels in exterior doors or within 36 inches of the inside activating device shall be of laminated security glass which is a minimum one-fourth inch in thickness with a six-hundredths-inch vinyl interlayer or one-fourth-inch polycarbonate security sheets or their equivalent. (10) Garage doors shall have an inside slide bolt lock or its equivalent located at the bottom of the garage door on the inside. (b) Sliding Glass Doors. (1) Sliding glass doors regulated by this code shall have a vertical hook bolt dead lock or shall comply with UBC Standard No. 10-5, Part II, or shall be labeled as “SECURITY TESTED” meeting the California Model Building Security Ordinance (CMBSO). Doors not so equipped or tested and labeled as complying with such standard shall be secured as follows: (A) Nonconforming sliding glass doors shall have a secondary bolt lock mounted on the bottom of the door. The bolt lock shall be no less than one-fourth inch in thickness and shall have a minimum throw of two inches. The bolt for such secondary lock shall be made of hardened steel and shall be securely fastened to the frame or floor. (B) Double sliding patio doors shall be capable of being locked at the meeting rail. (2) Noncrushable anti-lift devices shall be securely fastened in the top track of the door frame within three inches of each side of the moveable pane when in the closed position. (c) Window Security. (1) Window assemblies which are designed to be openable and which are regulated by this chapter shall have a vertical hook bolt dead lock or shall comply with UBC Standard No. 10-6, or shall be labeled as “SECURITY TESTED” meeting the California Model Building Security Ordinance (CMBSO) unless such windows are protected by approved metal bars, screens or grilles. Louvered windows regulated by this chapter shall be protected by approved metal bars or grilles. (2) Sliding glass windows not so equipped or tested and labeled as complying with such standard shall be secured as follows: (A) If a vertical hookbolt deadlock is used, it shall be of hardened steel and shall have a minimum thickness of one-eighth inch. The strike used for the vertical hook deadlock shall be made of hardened steel. When the vertical hookbolt deadlock is in the closed position, it shall be at least 108 around the strike. (B) If a secondary lock is used, along with a lock other than a vertical hookbolt deadlock, the secondary lock shall be mounted on the bottom of the window. The secondary lock shall be a bolt lock and shall be no less than one-eighth inch in thickness, and shall have a minimum throw of one-half inch. (3) All sliding glass windows shall have the movable section of the window on the inside of the fixed portion of the window. Noncrushable anti-lift devices shall be securely fastened in the top track of the window frame within three inches of each side of the moveable pane when in the closed position. (d) Address, Location and Specifications. (1) Residence numbers shall be located in a visible location near the garage door. (2) If the garage does not face the street, or is not connected to the dwelling at the street front, the numbers shall be located on the portion of the residence closest to the street. (3) All address numbers shall be internally lighted and shall be a minimum of four inches in height. The numbers shall be black in color, with the background being illuminated in white. (4) Plans for multifamily dwelling projects shall include an addressing program approved by the building official. (5) Address numbering shall be provided and maintained in a position which is plainly visible and legible from the street fronting the property. When properties do not front toward streets, addressing shall conform to the above requirements but front driveways and pedestrian ways. (6) In addition, multiple unit dwellings shall also erect and maintain lighted directories at each pedestrian entrance displaying building and unit numbers. (Ord. 2484 § 4, 9-24-02. 1990 Code § 7-2130.)

Ask a question about Fremont law

Corpus searches the Fremont sections it holds and shows the ones that match, with their citations. Free, no sign-in.