§ 15.66.100 — Amendment to 2025 CWUIC Sections 503, 504 (Special Building Construction Regulations)
Fremont Municipal Code (Fremont Municipal Code current through Ordinance 02-2026 passed May 5, 2026 (Code Publishing Company, codepublishing.com, scraped 2026-11-18)) · Fremont Municipal Code § 15.66.100
Corpus is an independent public-information project, not the official City of Fremont website. Stable reference: corpuslaw.us/code/df5e8473-9ca3-466f-9343-dae96a340aa4
15.66.100 Amendment to 2025 CWUIC Sections 503, 504 (Special Building Construction Regulations).
Section 503 of the 2025 California Wildland-Urban Interface Code is amended as follows: 503.1.1 Establishment of limits. The establishment of limits for the Wildland-Urban Interface (WUI) Fire Area’s required construction methods shall be designated under the California Public Resources Code for the State Responsibility areas and by the areas designated as Very High Fire Hazard Severity Zones by the city of Fremont under Government Code Section 51179 as set forth in Fremont Municipal Code, Chapter 15.65 for areas outside the State Responsibility areas and within the city of Fremont. 503.2- 503.3.4 {CWUIC text not modified} Section 504 of the 2025 California Wildland-Urban Interface Code is amended as follows: 504.2 – 504.2.1 {CWUIC text not modified} 504.2.1.1 Wildland Urban-Interface Fire Area. The roof covering of any new structure or the re-roofing of any existing building within Wildland-Urban Interface Fire Area, regardless of the type of construction or occupancy classification, shall be a fire-retardant roof covering that is at least Class A. All alteration, repair, replacement or reroofing shall conform to the applicable provisions of the 2025 California Building Code Section 1604 “General Design Requirements” and any other applicable engineering requirements, including Chapter 15, “Roof Assemblies and Rooftop Structures” of this code. 504.2.2 {CWUIC text not modified} 504.5 – 504.5.2.1 {CWUIC text not modified} 504.5.2.2 Exterior wall covering. All exterior faces of the exterior walls shall be of an assembly qualified for exterior face of recognized 1-hour fire resistive assemblies. All exterior wall coverings shall meet a Class I flame spread requirement and be installed over materials approved for 1-hour fire-resistive construction. Exception: Class I flame spread requirement may be waived for additions not to exceed 50%, cumulatively over the life of the structure, of the existing structure, including garage areas with 1-hour fire resistive exterior wall assembly. 504.6 – 504.7.1 {CWUIC text not modified} 504.7.1.2 Utilities. Utilities, pipes, furnaces, water heaters or other mechanical devices located in an exposed under-floor area of a building or structure shall be enclosed with material as required for exterior, 1-hour, fire-resistive construction. Adequate covered access opening for servicing such utilities shall be provided as required by appropriate codes. 504.7.1.3 Historical buildings. Repairs, alterations, and additions necessary for the preservation, restoration, rehabilitation or continued use of a building or structure may be made without conformance to all the requirements of this code when authorized by the building official, provided: 1. The building or structure conforms to Part 8, Title 24, of the California Code of Regulations; and 2. A fire protection plan is implemented so that the building or structure will be no more of a fire hazard than any new building. The plan must be prepared and signed by a registered Fire Protection Engineer. The plan must be approved by the building official and fire chief prior to the commencement of any work. (Ord. 12-2025 § 2, 9-16-25.)
Ask a question about Fremont law
Corpus searches the Fremont sections it holds and shows the ones that match, with their citations. Free, no sign-in.