15.75.200 Basic structural checklist.
The following checklists apply to the voluntary investigation and analysis of buildings under Section 15.75.060(a): (a) Building Systems. | Compliant | Noncompliant | N/A | BUILDING SYSTEMS | | | | | | | | LOAD PATH: The structure shall contain one complete load path for seismic force effects from any horizontal direction that serves to transfer the inertial forces from the mass to the foundation. | | | | WEAK STORY: The strength of the lateral-force system in any story shall not be less than 80% of the strength in an adjacent story above or below. | | | | SOFT STORY: The stiffness of the lateral-force resisting system in any story shall not be less than 70% of the stiffness in an adjacent story above or below or less than 80% of the average stiffness of the three stories above or below. | | | | VERTICAL DISCONTINUITIES: All vertical elements in the lateral-force resisting systems shall be continuous to the foundation. | | | | DETERIORATION OF WOOD: There shall be no signs of decay, shrinkage, splitting, fire damage, or sagging in any of the wood members and none of the metal accessories shall be deteriorated, broken, or loose. | | | | WALL ANCHORAGE: Exterior concrete or masonry walls shall be anchored for out-of-plane forces at each diaphragm level with steel anchors or straps that are developed into the diaphragm. Straps shall be minimum 7 gauge. (b) Vertical Lateral Force Resisting System. | Compliant | Noncompliant | N/A | VERTICAL LATERAL FORCE RESISTING SYSTEM | | | | | | | | REDUNDANCY: The number of lines of shear walls in each principal direction shall be greater than or equal to 2. | | | | STUCCO (EXTERIOR PLASTER) SHEAR WALLS: Multistory buildings shall not rely on exterior stucco walls as the primary lateral force-resisting systems. | | | | GYPSUM WALLBOARD OR PLASTER SHEAR WALLS: Interior plaster or gypsum wallboard shall not be used as shear walls on buildings over one story in height. | | | | NARROW WOOD SHEAR WALLS: Narrow wood shear walls with an aspect ratio greater than 2 to 1 for Life Safety shall not be used to resist lateral forces developed in the building. | | | | WALLS CONNECTED THROUGH FLOORS: Shear walls shall have interconnection between stories to transfer overturning and shear forces through the floor. | | | | HILLSIDE SITE: For a sloping site greater than 1 vertical to 3 horizontal and with greater than one-half story above the base, the base shear in the downhill direction, including forces from the base level diaphragm, shall be resisted through primary anchors from diaphragm struts or collectors provided in the base level framing to the foundation. | | | | CRIPPLE WALLS: All cripple walls below first floor level shear walls shall be braced to the foundation with shear elements. (c) Connections. | Compliant | Noncompliant | N/A | CONNECTIONS | | | | | | | | WOOD POSTS: There shall be a positive connection of wood posts to the foundation. | | | | WOOD SILLS: All wood sills shall be bolted to the foundation. | | | | GIRDER/COLUMN CONNECTION: There shall be a positive connection between the girder and the column support. | | | | WOOD SILL BOLTS: Sill bolts shall be spaced at 6 ft. or less, with proper edge distance provided for wood and concrete. (d) Horizontal Lateral Force Resisting System. | Compliant | Noncompliant | N/A | HORIZONTAL LATERAL FORCE RESISTING SYSTEM1 | | | | | | | | OPENINGS: Walls with garage doors or other large openings shall be braced with plywood shear walls or shall be supported by adjacent construction through substantial positive ties. | | | | HOLD-DOWN ANCHORS: All walls shall have properly constructed hold-down anchors. | | | | DIAPHRAGM CONTINUITY: The diaphragms shall not be composed of split level floors. In wood buildings, the diagrams shall not have expansion joints. | | | | STRAIGHT SHEATHING: All straight sheathed diaphragms shall have aspect ratios less than 2 to 1. | | | | SPANS: All wood diaphragms with spans greater than 24 feet shall consist of wood structural panels or diagonal sheathing. Wood commercial and industrial buildings may have rod-braced systems. | | | | UNBLOCKED DIAPHRAGMS: All unblocked wood structural panel diaphragms shall have horizontal spans less than 40 feet and shall have aspect ratios less than or equal to 4 to 1. (Ord. 10-2007 § 25, 5-1-07. 1990 Code § 7-10307.)
1 The basic structural checklist shall be completed prior to completing this supplemental structural checklist.
Ask a question about Fremont law
Corpus searches the Fremont sections it holds and shows the ones that match, with their citations. Free, no sign-in.