15.80.090 Retrofit standards and requirements.

(a) Sections 506 and 507 of Appendix Chapter 5 of the 1997 Uniform Code for Building Conservation (UCBC) and all subsequent corresponding sections of the UCBC or successor code which refer to the then-latest edition of the California Building Code are hereby adopted with the following modifications: (1) Section 506.1 of the 1997 UCBC is modified to read as follows: 506.1 Reinforced Concrete and Reinforced Masonry Wall Anchorage. Concrete and masonry walls shall be anchored to all floors that provide lateral support for the wall. The anchorage shall provide a positive direct connection between the wall and floor or roof construction capable of resisting 75 percent of the horizontal forces specified in the Building Code. (2) Section 506.2 of the 1997 UCBC is modified to read as follows: 506.2 Special Requirements for Wall Anchorage Systems. The steel elements of the wall anchorage system and continuity ties shall be designed in accordance with the Building Code using a load factor of 1.7 for allowable stress design. Wall anchors shall be provided to resist out-of-plane forces, independent of existing shears anchors. Exception: Existing cast-in-place shear anchors may be used as wall anchors if the tie element can be readily attached to the anchors and if the engineer or architect can establish tension values for the existing anchors through the use of approved as-built plans or testing, and through analysis showing that the bolts are capable of resisting the total shear load (including dead load) while being acted upon by the maximum tension force due to earthquake. Criteria for analysis and testing shall be determined by the building official. Expansion anchors are only allowed with special inspection and approved testing for seismic loading. Attaching the edge of plywood sheathing to steel ledgers is not considered as complying with the positive anchoring requirements of this chapter. Attaching the edge of steel decks to steel ledgers is not considered as providing the positive anchorage of this chapter unless testing and/or analysis are performed that establish shear values for the attachment perpendicular to the edge of the deck. Any installation shall be subject to special inspection. (b) The structural retrofit of buildings within the scope of this chapter shall comply with all provisions in Sections 506 and 507 of Appendix Chapter 5 of the 1997 UCBC as modified herein, and all subsequent corresponding sections of the UCBC or successor code which refer to the then latest edition of the California Building Code. (Ord. 2405 § 1, 10-10-00. 1990 Code § 7-11140.)

Ask a question about Fremont law

Corpus searches the Fremont sections it holds and shows the ones that match, with their citations. Free, no sign-in.