§ 18.200.080 — Provisions for flood hazard reduction
Fremont Municipal Code (Fremont Municipal Code current through Ordinance 02-2026 passed May 5, 2026 (Code Publishing Company, codepublishing.com, scraped 2026-11-18)) · Fremont Municipal Code § 18.200.080
Corpus is an independent public-information project, not the official City of Fremont website. Stable reference: corpuslaw.us/code/83e5379b-b98e-4284-8f7f-1a4763f6a33f
18.200.080 Provisions for flood hazard reduction.
(a) Standards of Construction. In all areas of special flood hazards, the following standards are required: (1) Anchoring. (A) All new construction and substantial improvements shall be anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy. (B) All manufactured homes shall meet the anchoring standards of subsection (d) of this section. (2) Construction Materials and Methods. (A) All new construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage. (B) All new construction and substantial improvements shall be constructed using methods and practices that minimize flood damage. (C) All new construction and substantial improvements shall be constructed with electrical, heating, ventilation, plumbing and air conditioning equipment and other service facilities that are designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding. (D) Require, within zones AH or AO, adequate drainage paths around structures on slopes to guide floodwaters around and away from proposed structures. (3) Elevation and Floodproofing. (A) New construction and substantial improvement of any structure shall have the lowest floor, including basement, elevated to the minimum elevation of the lowest floor as required by the Fremont Building Standards Code (Chapter 15.10) but no lower than one foot above the base flood elevation. Nonresidential structures may meet the standards in subsection (a)(3)(C) of this section. Upon completion of the structure, the elevation of the lowest floor, including basement, shall be certified by a registered professional engineer or surveyor and verified by the floodplain administrator to be properly elevated. (B) New construction and substantial improvement of any structure in zone AO shall have the lowest floor, including basement, elevated above the highest adjacent grade at least as high as the depth number specified in feet on the FIRM plus one foot of freeboard, or at least three feet if no depth number is specified. Nonresidential structures may meet the standards in subsection (a)(3)(C) of this section. Upon the completion of the structure, the elevation of the lowest floor, including basement, shall be certified by a registered professional engineer or surveyor or verified by the floodplain administrator to be properly elevated. (C) Nonresidential construction shall either be elevated in conformance with subsection (a)(3)(A) or (B) of this section or, together with attendant utility and sanitary facilities: (i) Be floodproofed so that below one foot above the base flood elevation the structure is watertight with walls substantially impermeable to the passage of water; (ii) Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy; and (iii) Be certified by a registered professional engineer or architect that the standards of this subsection are satisfied. Such certification shall be provided to the floodplain administrator. (D) Require, for all new construction and substantial improvements, that fully enclosed areas below the lowest floor that are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or meet or exceed the following minimum criteria: (i) Either a minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided; the bottom of all openings shall be no higher than one foot above grade; openings may be equipped with screens, louvers, valves or other coverings or devices; provided, that they permit the automatic entry and exit of floodwaters; or (ii) Be certified to comply with a local floodproofing standard approved by the Federal Insurance Administration. (E) Manufactured homes shall, in addition to the requirements of this subsection, meet the standards in subsection (d) of this section. (F) Flood Openings. All new construction and substantial improvements of structures with fully enclosed areas below the lowest floor (excluding basements) that are usable solely for parking of vehicles, building access or storage, and which are subject to flooding, shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwater. Designs for meeting this requirement must meet the following minimum criteria: (i) For nonengineered openings: a. Have a minimum of two openings on different sides having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding; b. The bottom of all openings shall be no higher than one foot above grade; c. Openings may be equipped with screens, louvers, valves or other coverings or devices; provided, that they permit the automatic entry and exit of floodwater; and d. Buildings with more than one enclosed area must have openings on exterior walls for each area to allow flood water to directly enter; or (ii) Be certified by a registered civil engineer or architect. (b) Standards for Utilities. (1) All new and replacement water supply and sanitary sewage systems shall be designed to minimize or eliminate infiltration of floodwaters into the system and discharge from systems into floodwaters. (2) On-site waste disposal systems shall be located to avoid impairment to them or contamination from them during flooding. (c) Standards for Subdivisions and Other Proposed Development. (1) The requirements of this subsection (c) apply (A) to all proposed new subdivisions of all lot sizes and (B) to all other proposed development on parcels greater than five acres. New proposals shall: (A) Identify the flood hazard area and the elevation of the base flood. (B) Identify the elevations of the lowest floor of all proposed structure(s) and pads on the final plans. If the site is filled above the base flood, the final pad elevation shall be certified by a registered professional engineer or surveyor and provided to the floodplain administrator. (C) Be consistent with the need to minimize flood damage. (D) Have public utilities and facilities such as sewer, gas, electrical and water systems located and constructed to minimize flood damage. (E) Provide adequate drainage to reduce exposure to flood hazards. (d) Standards for Manufactured Homes. All new and replacement manufactured homes and additions to manufactured homes shall: (1) Be elevated so that the lowest floor meets the minimum elevation of the lowest floor as required by the Fremont Building Standards Code (Chapter 15.10) but no lower than one foot above the base flood elevation; and (2) Be securely anchored to a permanent foundation system to resist flotation, collapse or lateral movement. (e) Floodways. Located within areas of special flood hazard established in Section 18.200.060(b) are areas designated as floodways. Since the floodway is an extremely hazardous area due to the velocity of floodwaters which carry debris, potential projectiles, and erosion potential, the following provisions apply: (1) Prohibit encroachments, including fill, new construction, substantial improvements, and other development unless certification by a registered professional engineer or architect is provided demonstrating that encroachments shall not result in any increase in flood levels during the occurrence of the base flood discharge. (2) If subsection (e)(1) of this section is satisfied, all new construction and substantial improvements shall comply with all other applicable flood hazard reduction provisions of this section. (f) Coastal High-Hazard Areas. Within coastal high-hazard areas established in Section 18.200.060(b), the following standards shall apply: (1) All new construction and substantial improvements shall be elevated on adequately anchored pilings or columns and securely anchored to such pilings or columns so that the lowest horizontal portion of the structural members of the lowest floor (excluding the pilings or columns) meets the minimum elevation as required by the Fremont Building Standards Code (Chapter 15.10) but no lower than one foot above the base flood elevation. The pile or column foundation and structure attached thereto shall be anchored to resist flotation, collapse, and lateral movement due to the effects of wind and water loads acting simultaneously on all building components. Water loading and wind loading values used shall be those required by applicable state building standards and the Fremont Building Standards Code (Chapter 15.10). (2) All new construction shall be located on the landward side of the reach of mean high tide. (3) All new construction and substantial improvements shall have the space below the lowest floor free of obstructions or constructed with breakaway walls. Such temporarily enclosed space shall not be used for human habitation. (4) Fill shall not be used for structural support of buildings. (5) Manmade alteration of sand dunes which would increase potential flood damage is prohibited. (6) The floodplain administrator shall obtain and maintain the following records: (A) Certification by a registered engineer or architect that a proposed structure complies with subsection (f)(1) of this section. (B) The elevation (in relation to mean sea level) of the bottom of the lowest structural member of the lowest floor (excluding pilings or columns) of all new and substantially improved structures, and whether such structures contain a basement. (g) Standards for Recreational Vehicles. (1) All recreational vehicles placed in zones A1-30, AH, AE, V1-30 and VE as shown on the FIRMs will either: (A) Be on the site for fewer than 180 consecutive days; or (B) Be fully licensed and ready for highway use. A recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached additions; or (C) Meet the permit requirements of Section 18.200.070(a) and the elevation and anchoring requirements for manufactured homes in Section 18.200.080(d). (Ord. 1829 § 1, 7-26-88; Ord. 27-2016 § 36, 12-6-16; Ord. 03-2023 § 3, 3-21-23. 1990 Code § 8-8107.)
Ask a question about Fremont law
Corpus searches the Fremont sections it holds and shows the ones that match, with their citations. Free, no sign-in.