§ 18.43.110 — Development standards – Urban neighborhood zone (“UN”)
Fremont Municipal Code (Fremont Municipal Code current through Ordinance 02-2026 passed May 5, 2026 (Code Publishing Company, codepublishing.com, scraped 2026-11-18)) · Fremont Municipal Code § 18.43.110
Corpus is an independent public-information project, not the official City of Fremont website. Stable reference: corpuslaw.us/code/8b80c9da-624e-4b6a-bb63-cb30e7897b1d
18.43.110 Development standards – Urban neighborhood zone (“UN”).
(a) Intent and Purpose. The “UN” zone is applied to areas generally west and south of the downtown to support the downtown and employment core areas with a wide variety of housing opportunities, neighborhood services, office, neighborhood retail, and regional retail at The Hub shopping center. (b) Intended Physical Character – Buildings, Frontages. Buildings are a combination of primarily block-form with some house-form buildings along transitions to existing neighborhoods. Buildings are up to six stories, mixed and single use, with a variety of commercial uses and services. Buildings are near or at the sidewalk to spatially define the streetscape. Massing is toward the front of buildings to spatially define the wide streets, provide service area in the rear, and promote compatibility with neighboring properties. Mixed- or single-use, two- to six-story buildings at or near the sidewalk with residential frontages to share the streetscape and for comfort of ground floor dwelling. (c) Streetscape/Public Realm and Open Space. The streetscape is in support of pedestrian activity and consists of a range of frontages such as shopfronts with wide awnings near some corners and forecourts, terraces, stoops, and parking courts. Wide sidewalks provide for comfortable strolling and easy view of retail merchandise where shopfronts are allowed. Signage is in support of the wide variety of business activity in these areas. Open spaces are urban and provide community gathering space in support of high pedestrian activity and civic events. Housing can occupy upper floors with ground floors also with dwellings, services or retail when within 100 feet of a street corner. (d) Land Use Activity. Land use activity consists of a range of housing choices with limited supporting retail, restaurant, and service activity. In the shopping center known as “The Hub,” nonresidential activity is vibrant and ranges from general retail, restaurants, grocery, bakery/deli, to office and personal services. Transitional housing forms such as single- or mixed-use townhouses and/or lofts provide this zone with the widest variety of choices of the three city center zones. (e) Parking. Nonresidential parking is minimal and grouped to be shared as practical, including on-street parking. Residential parking is provided on the site of its building or remotely, as allowed. (f) Building Placement. (1) One building shall be located within each building site per Diagram 1. One parcel may have several building sites per the standards below. (2) Building facades along streets shall be located within the build-to-layer per Diagram 1. (3) Building facades shall extend along the frontages of the building site per subsection (h) of this section of these requirements. (4) Projects with at least 20,000 square feet of building site area shall provide at least 15 percent on-site public and semipublic open space per Section 18.43.070(b). Residential projects shall provide private open space per Section 18.43.070(b)(2). Table 18.43.110F – UN Building Placement Standards | REQUIREMENT | MIN | MAX | a | Building site width | 200' | 400' | b | Building site depth | 100' | 400' | FS | Front setback (0 ft within 100 ft of corner) | 0' or 10' | 15' | SS | Side street setback (0 ft within 50 ft of corner) | 10' | 15' | S | Side setback1 | 0' | n.a. | RS | Rear setback2 | 10' | n.a. | TA | Setback within code boundary transition area per Figure 18.43.050 | 100': stories 4 through 6 1 Fire code – Building protection per local fire/safety code. 2 Where an alley provides vehicular access, minimum setback is five feet. (g) Building Height and Massing. (1) Buildings shall comply with the standards table below, measured in stories and feet. (2) For every 100 feet of building length, there shall be a plane-break along the facade comprised of an offset of at least five feet in depth by 25 feet in length. The offset shall extend from grade to the highest story. Table 18.43.110G – UN Building Height and Massing Standards | REQUIREMENT | MIN | MAX | BH | Building height: stories and feet | 2/25 | 6/751 | TH | Building height within the code boundary transition area per Figure 18.43.050 | no min. | 3/36 | GF | Ground floor level above grade: | nonresidential | 0' | 4' | residential | 18" | 6' | GH | Height of ground floor | 16' | none | UH | Height of upper story | 10' | none 1 See Chapter 18.250 for the process and requirements to request increases in allowed building height. Architectural elements such as roofs, parapets and finials are allowed up to 110 feet. (h) Frontages and Encroachments. (1) Using only the allowed frontage types, buildings shall incorporate one or multiple frontage types with facades extending along frontage lines per Diagram 3. (2) Buildings and their additions shall be designed to coordinate the ground floor level with the requirements for frontage in this subsection. (3) Buildings may incorporate multiple frontage types, as allowed by Sections 18.43.230 to 18.43.270, subject to design review. (4) Building elements may encroach into setbacks as allowed by the FMC. (5) Landscaping shall be provided along frontages per the applicable frontage type requirements in Sections 18.43.230 to 18.43.270. Table 18.43.110H – UN Frontage and Encroachment Standards | Percent of ground floor facade required in build-to-layer | FRONTAGE LOCATION | Min. beginning from nearest street corner or building side corner | Along primary street | 75 | Along side street | 65 | ALLOWED FRONTAGES | Shopfront (when within 100 ft of street corner) | See Table 18.43.220 | Forecourt | See Table 18.43.220 | Terrace (1) | See Table 18.43.220 | Stoop (1) | See Table 18.43.220 | Parking Court (not on Paseo Padre) | See Table 18.43.220 | (1) Not allowed on Paseo Padre, Civic Center, Fremont | EI ENCROACHMENT ALONG REAR | Per FMC (i) Parking Placement and Access. (1) Parking shall be located as shown in Diagram 4. To the extent practical, utilities shall be underground and/or in alleys. (2) Parking and service areas shall only be accessed from a primary street if an alley or side street are not present. (3) Parking entries shall not exceed 20 feet in width and shall be designed as integral, decorative components of the building facade. Table 18.43.110I – UN Parking and Placement Access Standards | | | MIN | SCREENING REQUIREMENT | FS | Front Setback | 50' | By the building | RSA | Rear Setback to Alley | 5' | By the building, or min. 2' tall decorative wall or hedge when within 10' of side street | RS | Rear Setback No Alley | 10' | None, except when adjacent to residential, then min. 5' tall wall or fence | SS | Side Street Setback | 10' | Min. 2' to 4' tall decorative wall or vine hedge | 7' | For parking court, see Table 18.43.220 | S | Side Setback | 0' | None, except when adjacent to residential, then min. 5' tall decorative wall or fence | PE | Parking Entry | Corner lot: min. 75' from street corner Interior lot: within 5' of either side when side street or alley are not present (Ord. 15-2015 § 2 (Exh. B), 6-2-15.)
Ask a question about Fremont law
Corpus searches the Fremont sections it holds and shows the ones that match, with their citations. Free, no sign-in.
