§ 18.49.070 — WSI district site and building development standards
Fremont Municipal Code (Fremont Municipal Code current through Ordinance 02-2026 passed May 5, 2026 (Code Publishing Company, codepublishing.com, scraped 2026-11-18)) · Fremont Municipal Code § 18.49.070
Corpus is an independent public-information project, not the official City of Fremont website. Stable reference: corpuslaw.us/code/35033250-2e70-4b86-9870-f794a21d6f96
18.49.070 WSI district site and building development standards.
(a) New development, redevelopment, expansions and additions shall conform to the site development standards set forth in Table 18.49.070. For nonresidential uses, intensity is measured in terms of floor area ratio (FAR). For residential uses, density is measured in terms of dwelling units per net acre (du/ac). (b) When at least 50 percent of a building’s site area lies within a one-quarter- or one-half-mile radius of the BART radius station the project must meet the standards set forth in Table 18.49.070 for the area within the radius. When less than 50 percent of the building’s site area is located within one-quarter- or one-half-mile BART radius, the project may utilize the standard for the area within the radius but is only required to use the standard for outside the radius. (c) For decreases to the minimum FARs prescribed in Table 18.49.070, the approval authority must make the following finding: (1) The urban form intent of the WS/SF CP is achieved. (d) Density Standards. (1) Purpose and Intent. The number of dwellings per unit of land, the density, is controlled so that housing can match the availability of public services and the support of commercial areas. The standards also allow the housing density to be matched with the carrying capacity of the land. In addition, the density standards are used as one type of control of overall building bulk. Finally, minimum density standards ensure that the service capacity is not wasted and that the city’s housing goals are met. (2) Density Calculations. (A) When the density calculation for a parcel results in a fraction of one-half or greater, the density shall be rounded up to the next whole unit. (B) When the density calculation results in a fraction less than one-half, the density shall be rounded down to the next whole unit. (C) Minor deviations of no more than one dwelling above or below the permitted range may be allowed when rounding the density calculation. (D) For purposes of density calculations and density bonus allowances, efficiency apartments or single room occupancy units shall count as one-half a dwelling unit. (3) Density Bonuses and Density Redistribution. (A) Density bonuses above the permitted density range of a district shall be allowed subject to the provisions of Chapter 18.165, the general plan and state law. (B) For projects that propose a density redistribution wherein the respective density of one or more of the housing product types is either above or below the permitted density range established by the WS/SF CP and WSI zoning for the development site; the planning commission shall review and make a recommendation and the city council shall be the final approval authority for the project. (e) Alternatives to Building Setbacks and Streetwall Standards Adjacent Streets. Modified building setbacks or streetwall standards may be approved through design review when the approval authority determines that creative design solutions are incorporated, including, but not limited to: (1) Provision of high quality, publicly accessible open space areas or plazas; (2) Incorporation of architectural elements (e.g., trellis, columns, light standards, wind turbines or other features) that frame the site and create a clear edge to the public realm, connect the building to the street, reinforce building corner zones, welcome pedestrians into the site and guide them toward the building entries; (3) Parking areas within setbacks are avoided but if they occur, they are designed with high quality pavement materials other than asphalt. Paver stones, textured/scored concrete are considered acceptable; and/or (4) Incorporation of well-designed pedestrian pathways with pedestrian-scale amenities from building entries to surrounding sidewalks and within all open space areas. (f) For modifications to the bulk and massing requirements prescribed in Table 18.49.070, the approval authority must find that the design is consistent with the intent of the WS/SF CP to support the creation of well proportioned buildings that contribute to the formation of an appropriately scaled environment, and reinforce a pedestrian focused environment that is visually engaging. Table 18.49.070 In Table 18.49.070, the letters and symbols are defined as follows: KSF = 1,000 Gross Square Feet SF = Square Feet Unit = Dwelling Unit Required Site Development Standards for WSI District | Required Site Development Standards | Intensity (by land use type): | Land Use Type | Minimum FAR within 1/2 mile of BART | Minimum FAR within remainder of Plan Area | Industrial | 0.50 | 0.35 | Research and Development | 0.50 | 0.35 | Office and Convention | 1.50 | 0.50 | Lodging | 1.50 | 1.00 | Assembly and Other Nonresidential Uses | Part of the minimum FAR for a larger project | Density (BART proximity) | Land Use Type | Minimum (Units/Acre) within 1/4 mile of BART | Minimum (Units/Acre) within remainder of Plan Area | Residential | 50 | 30 | Open Space | Land Use Type | Minimum | Nonresidential | 2.5% of gross floor area | Residential – Common | 500 SF for first 5 units + 50 SF for each additional unit | Residential – Private/Unit | 48 SF balcony (6' minimum interior dimension) or 80 SF patio (8' minimum interior dimension) | Building Setbacks to Adjacent Streets2,3 | Land Use Type | Minimum/Maximum (Feet) | Allowable Projections | Industrial/School | 15/20 | ≤ 55% of building street frontage. See Section 4.2 of the WS/SF CP | Research and Development | 8/12 | Assembly and Other Nonresidential Uses | 8/12 | Residential | 8/12 | Building Setbacks, Other3 | Building Type | Minimum/Maximum (Feet) | Allowable Projections | All Building Types | Per Design Review | n/a | Streetwall4 | Land Use Type | Minimum (%) | Exclusions and Variations | Office, Research and Development | 50 | See Section 4.3 of the WS/SF CP | Retail and Entertainment | 80 | Residential | 70 | All Other Uses | Exempt | Corner Zones5 | 100 | Occupied Habitable Space (measured perpendicular from streetwall) | Minimum Depth 18 feet | Ground Floor Articulation | Maximum Average (feet) | Office, Research and Development | 35 | Retail and Entertainment | 30 | Residential | 25 | All Other Uses | Exempt | Building Height | | Minimum | Maximum | Nonresidential buildings | 2 stories in appearance | See WS/SF CP Chapter 4.5 and Figure 4.11 | Nonresidential ground floor as measured from finished floor to finished ceiling | 15 feet | Residential buildings | 3 stories | Residential buildings ground floor | 10 feet | Bulk and Massing6,8 | Total Building Height | Max Floor Plate (SF) | Max Plan Length (feet) | Max Diagonal (feet) | Max Apparent Face 1 (feet) | Max Apparent Face 2 (feet) | Minimum Change in Apparent Face | Up to 35 feet | n/a | n/a | n/a | Residential: 20 Nonres: 35 | n/a | 1' deep x 1' wide notch or 2' offset of building massing | 35'-1" to 65 feet | n/a | n/a | n/a | 120 | 80 | 2' deep x 3' wide notch or 2' facade setback | 65'-1" to 85 feet | 20,000 | 200 | n/a | 80 | 40 | 5' deep x 5' wide notch or 5' facade setback | 85'-1" to 135 feet | 10,000 | 140 | 170 | 105 | 40 | 10' deep x 10' wide notch or 10' facade setback | 135'-1" to 240 feet | 12,000 | 140 | 170 | 110 | 40 | 10' deep x 10' wide notch or 10' facade setback | Vehicular Parking by Use | Land Use Type | Maximum | Minimum | Assembly and Convention | 3 spaces/KSF | 1 space/5 seats | Hotel | 1 space/guest room | n/a | Industrial | 3 spaces/KSF | n/a | Office | 3 spaces/KSF | n/a | Research and Development | 3 spaces/KSF | n/a | Residential within 1/4 mile of the BART Station | 1.5 spaces/unit7 | n/a | Residential outside 1/4 mile of the BART Station | 2 spaces/unit | n/a | Retail and Service | 3 spaces/KSF | n/a | School | 1 space/employee | n/a | Uses not listed above | Shall be based upon Section 18.183.030 but may be reduced by the approval authority given the transit-oriented nature of the use. | Loading Spaces | Standard | Minimum | Maximum | Width | 10 feet | n/a | Vertical Clearance | 16 feet | Bicycle Parking by Use | Land Use Type | Short-term (visitor) spaces | Long-term (tenant) spaces | Support facilities | Nonresidential | 4, plus 5% of maximum allowable automobile parking for visitors | 1, plus 5% of maximum allowable automobile parking for tenants or occupants | 1 shower per gender/changing facility/100 employees | Residential buildings with shared parking facilities | 4, plus 0.10/unit | 2, plus 0.50/unit | n/a | Residential buildings with an individual private garage | 4, plus 0.10/unit | none | n/a | Other Parking Standards | | See Section 18.49.080 and Chapter 18.183 | Other Required Standards | | See Section 18.49.090 1 Assembly and other nonresidential uses to be approved only as part of a larger building. 2 Horizontal distance, measured perpendicularly, from the property line to the predominant building wall closest to the property line excluding permitted projections. 3 Final setbacks will be determined as part of the design review permit and may be modified if necessary to meet building code or fire code requirements. 4 Streetwall is defined as that portion of the building massing directly fronting onto either a public right-of-way or easement that is constructed to the minimum setback line. Streetwall standards may be modified through design review in accordance with Section 18.49.070(e). 5 A corner zone is defined as the area a minimum of 30' from the corner of a building and a minimum of 35' high, along a streetwall. 6 See WS/SF CP Chapter 4.6 and Figures 4.12 through 4.15 for further detail. 7 To foster early development activity in the absence of amenities and nearby services, for-sale projects that record a final map prior to December 31, 2019, may provide up to two spaces per unit maximum. Project approvals granted before this date shall incorporate design provisions to allow parking in excess of one and one-half spaces per unit up to two residential spaces per unit to be made available on an unassigned basis. 8 For buildings greater than 65' in height, the portion of the building below 65' in height is subject to the bulk and massing standards for a 35'-1" to 65' tall building. The portion of the building above 65' in height is subject to the bulk and massing standards based on the total building height. For example, if a building is 100' tall, the bulk and massing standards for a 35'-1" to 65' tall building would apply to the bottom 65' of the building, and the bulk and massing standards for a 85'-1" to 135' tall building would apply to the top 35' of the building. (Ord. 28-2014 § 1, 9-9-14; Ord. 04-2016 § 20, 3-1-16; Ord. 27-2016 § 14, 12-6-16; Ord. 23-2018 § 13, 10-2-18; Ord. 02-2020 § 14, 1-14-20; Ord. 05-2021 § 21, 4-20-21; Ord. 01-2025 § 8, 1-7-25.)
Ask a question about Fremont law
Corpus searches the Fremont sections it holds and shows the ones that match, with their citations. Free, no sign-in.