§ 6-321.1 — FATS, OILS, & GREASE (FOG) CONTROL PROGRAM
Fresno Municipal Code (Supp. No. 55, Update 1 (online June 23, 2026): codified through Ordinance No. 2026-019) · Fresno Municipal Code § 6-321.1
Corpus is an independent public-information project, not the official City of Fresno website. Stable reference: corpuslaw.us/code/f1c8fad1-b543-43fc-926a-2d5e4735a077
SEC. 6-321.1. - FATS, OILS, & GREASE (FOG) CONTROL PROGRAM.
(a) Title. This section shall be referred to as the "City of Fresno FOG Control Program Ordinance" or "FOG Ordinance." (b) Purpose. The purpose of the FOG Ordinance is to reduce Sanitary Sewer Overflows and blockages, and to protect public health and the environment by minimizing public exposure to unsanitary conditions. By controlling the discharge of fats, oils and grease to the wastewater collection system, excessive buildup in sewer lines can be lessened, thereby increasing the system's operating efficiency and reducing the number of sewer line blockages and overflows. (c) Definitions. For purposes of this section, (1) "Food Service Establishment" or "FSE" means any facility defined in California Uniform Retail Food Service Establishments Law (CURFFL) Section 113785, and any commercial entity discharging into the city sewer system and is consequently regulated by the Control Authority, either directly or indirectly through a Joint Powers Agreement, operating in a permanently constructed structure such as a room. building, or place, or portion thereof, maintained, used, or operated for the purpose of storing, preparing, serving, or manufacturing, packaging, or otherwise handling food for sale to other entities, or for consumption by the public, its members or employees, and which has any process or device that uses or produces FOG, or grease vapors, steam, fumes, smoke or odors that are required to be removed by a mechanical exhaust ventilation system, as required in CURFFL Section 114296. A limited food preparation establishment is not considered a Food Service Establishment when engaged only in reheating, hot holding or assembly of ready to eat food products and as a result, there is no wastewater discharge containing a significant amount of FOG. A limited food preparation establishment does not include any operation that changes the form, flavor, or consistency of food. (2) "Food Service Establishment, Existing" or "Existing FSE" means any Food Service Establishment that has been in continuous operation since before the effective date of this ordinance under the same ownership. (3) "Grease Interceptor" means a plumbing appurtenance or appliance that is installed in a sanitary drainage system to intercept nonpetroleum fats, oils, and grease (FOG) from a wastewater discharge. Grease interceptor is a general term used to include gravity grease interceptors, grease removal devices and hydro-mechanical grease interceptors. (i) "Gravity Grease Interceptor" means a plumbing appurtenance or appliance that is installed in a sanitary drainage system to intercept nonpetroleum fats, oils, and grease (FOG) from a wastewater discharge and is identified by volume, 30 minute retention time, baffle(s), not less than two compartments, a total volume of not less than 300 gallons (1135 L), and gravity separation. Gravity grease interceptors are generally installed outside the facility. (ii) "Grease Removal Device" means a hydromechanical grease interceptor that automatically, mechanically removes nonpetroleum fats, oils and grease (FOG) from the interceptor, the control of which is either automatic or manually initiated. (iii) "Hydro-mechanical Grease Interceptor" means a plumbing appurtenance or appliance that is installed in a sanitary drainage system to intercept nonpetroleum fats, oils, and grease (FOG) from a wastewater discharge and is identified by flow rate, and separation and retention efficiency. The design incorporates air entrainment, hydromechanical separation, interior baffling, or barriers in combination or separately, and one of the following: a. External flow control, with air intake (vent), directly connected; b. External flow control, without air intake (vent) directly connected; c. Without external flow control, directly connected; d. Without external flow control, indirectly connected. Hydro-mechanical grease interceptors are generally installed inside the facility. (4) "Hot spots" means areas in sewer lines that have experienced Sanitary Sewer Overflows or that must be cleaned or maintained frequently to avoid blockages of the sewer system. (d) General FOG Discharge Prohibitions. No Food Service Establishment shall discharge or cause to be discharged into the sewer system FOG that may accumulate and/or cause or contribute to blockages in the sewer system or at the sewer lateral which connects the Food Service Establishment to the sewer system. (e) Specific FOG Prohibitions. The following specific prohibitions shall apply to all Food Service Establishments: (1) Discharge of any FOG-containing wastewater that is not connected to a grease interceptor is prohibited, unless a waiver has been granted in accordance with Subsection (m). (2) Non-grease laden sources such as, but not limited to, hand-wash sinks, toilets, urinals, and stormwater, shall not be connected to a grease interceptor. (3) No dishwasher shall be connected to a hydro-mechanical grease interceptor. (4) Discharge of wastewater with temperatures in excess of 140° F (60° C) into any hydro-mechanical grease interceptor is prohibited. (5) Garbage disposals (food grinders) shall be prohibited at all New Food Service Establishments. Existing Food Service Establishments shall remove all garbage disposals when they remodel or within one hundred eighty (180) days from receiving a notice from the Director to remove its garbage disposal(s) based on the Director's finding that the FSE at any time caused or contributed to an SSO. (6) Direct disposal of any waste cooking oil into any drain or cleanout that is connected to the sewer system is prohibited. (7) Introduction of any additive into a grease interceptor or directly into the sewer system for the purpose of emulsifying FOG, biologically/chemically treating FOG for grease remediation, or as a supplement to any grease interceptor maintenance is prohibited, unless specifically authorized in writing by the Director. (8) Discharge of any waste which has been removed from a grease interceptor into the sewer system is prohibited. (f) FOG Wastewater Discharge Permit Required. All Food Service Establishments shall obtain a FOG Wastewater Discharge Permit. Nothing in the permit is intended to relieve the Food Service Establishment of any local, state, or federal regulation. Any denial of a permit may be appealed following the procedure set forth in Chapter 1, Article 4 of this Code. (g) Permit Application. New Food Service Establishments may be required to complete a wastewater discharge permit application. FOG Wastewater Discharge Permit Applications shall include the following information: (1) Name, address, telephone number, description of the Food Service Establishment and service activities. (2) Name of any and all principals/owners of the Food Service Establishment. (3) Name and address of property owner or lessor and the property manager where the Food Service Establishment is located. (4) Floor, site and plumbing plans showing detailed sewer connections and grease interceptors. (5) Specifications of all grease interceptors. (6) Operational statement of the Food Service Establishment. (7) Any other information as may be specified in the application form. (h) FOG Wastewater Discharge Permit Conditions. (1) FOG Wastewater Discharge Permits must contain the following: (i) A statement that indicates the wastewater discharge permit duration. (ii) A statement that the wastewater discharge permit is nontransferable. (iii) A statement of applicable civil and criminal penalties for violation of permit and FOG ordinance. (2) FOG Wastewater Discharge Permits may contain the following conditions or limits if found necessary to meet the intent of this Ordinance by the Director: (i) Limits on discharge of FOG and other pollutants. (ii) Requirements to install, operate, and maintain adequate pretreatment devices including grease interceptors. (iii) Requirements for proper operation and maintenance of all pretreatment devices. (iv) Grease interceptor maintenance frequency and schedule. (v) Requirements for implementing, maintaining, and reporting on the status of Best Management Practices. (vi) Requirements for maintaining and submitting logs and records, including waste hauling records and manifests and to have such records available for inspection. (vii) Requirements to self-monitor. (viii) Additional requirements as may be determined to be reasonably appropriate by the Director or as specified by other Regulatory Agencies to protect the collection system. (ix) Other terms and conditions, which may be reasonably applicable to ensure compliance with the FOG Control Program. (i) FOG Wastewater Discharge Permit Modifications. FOG Wastewater Discharge Permit modifications are subject to Section 6-335 (h) of this Article consistent with the terms, requirements and policies in this section. (j) Best Management Practices. All Food Service Establishments shall implement Best Management Practices (BMPs) in an effort to minimize the discharge of FOG to the sewer system, including, but not limited to, the following, as applicable: (1) Installation of Drain Screens. Drain screens shall be installed on all drainage pipes in food preparation areas. (2) Segregation and Collection of Waste Cooking Oil. All waste cooking oil shall be collected and stored properly in recycling receptacles such as barrels or drums. Such recycling receptacles shall be maintained properly to insure that they do not leak. Licensed waste haulers or an approved recycling facility must be used to dispose of waste cooking oil. (3) Disposal of Food Waste. All food waste should be disposed of directly into the trash or garbage and not into sinks and shall be disposed of in a manner that will ensure against leakage in the trash container or anywhere else. (4) Employee Training. Employees of the Food Service Establishment shall be trained by ownership/management periodically as specified in the FOG wastewater discharge permit on the following subjects: (i) Dry-wiping pots, pans, dish ware and work areas before washing to remove grease. (ii) Properly disposing food waste and solids in plastic bags prior to disposal in trash bins or containers to prevent leaking and odors. (iii) The location and use of absorption products to clean under fryer baskets and other locations where grease may be spilled or dripped. (iv) Properly disposing grease or oils from cooking equipment into a proper grease receptacle without spilling. (5) Maintenance of Mechanical Exhaust Ventilation Filters. Filters shall be cleaned as frequently as necessary to be maintained in good operating condition. The wastewater generated from cleaning exhaust filters shall be disposed of properly. (6) Kitchen Signage. Best management and waste minimization practices shall be posted conspicuously in the food preparation and dishwashing areas at all times. (k) FOG Pretreatment Required for New and Existing Food Service Establishments. Food Service Establishments are required to install, operate and maintain an approved type and adequately sized gravity grease interceptor necessary to maintain compliance with the objectives of this section, subject only to the variance and waiver provisions and other exceptions of this section. The gravity grease interceptor shall be adequate to separate and remove FOG contained in wastewater discharges from Food Service Establishments prior to discharge to the sewer system. Fixtures, equipment, and drain lines located in the food preparation and cleanup areas of Food Service Establishments that are sources of FOG discharges shall be connected to the gravity grease interceptor. (1) New Food Service Establishments shall include and install gravity grease interceptors prior to commencing discharges of wastewater to the sewer system. (2) Existing Food Service Establishments shall install gravity grease interceptors in any of the following circumstances: (i) When the FSE changes ownership; (ii) When any change in operation results in or has the potential to result in the increase of the amount of FOG generated and/or discharged by the FSE in an amount that alone or collectively causes or creates a potential SSO to occur; (iii) When it is determined by the Director that the FSE caused or contributed to grease-related blockages in the sewer system, has sewer laterals connected to hot spots, or has been determined to contribute significant FOG to the sewer system, based on inspection and sampling; (iv) During a remodel; (v) Any other time the Director reasonably determines that installation of a grease interceptor is necessary to avoid an adverse impact to the sewer system. (3) Any Existing FSE that receives a notice from the Director to install a gravity grease interceptor must install the interceptor within 180 days unless otherwise required by the Director. (l) Variance of Gravity Grease Interceptor Requirement. Notwithstanding any other provision in this section, an FSE may obtain a variance, at the Director's discretion, from the gravity grease interceptor requirement to allow alternative pretreatment technology that is equally effective in controlling the FOG discharge in lieu of a gravity grease interceptor. The variance may be rescinded if subsequent monitoring shows accumulation of FOG in the sewer lateral or the collection system downstream of the Food Service Establishment's connection or if the Food Service Establishment caused or contributed to a Sanitary Sewer Overflow. A gravity grease interceptor must be installed within 180 days of the rescission of a variance. Denial or revocation of a variance may be appealed pursuant to Chapter 1, Article 4 of this Code. (m) Waiver from Grease Interceptor Requirement. When granting a variance is not possible because the installation of a grease interceptor is not feasible and no equivalent alternative pretreatment can be implemented, an FSE may apply for and be granted a conditional waiver with the imposition of line maintenance cost recovery charges as established in the Master Fee Schedule. An FSE requesting a waiver must demonstrate that it has negligible FOG discharge and insignificant impact to the sewer system. Although a waiver may be granted, the Director may impose additional requirements including, but not limited to, the requirement to provide space and plumbing segregation for future installation of a grease interceptor. Denial or revocation of a waiver may be appealed pursuant to Chapter 1, Article 4. (n) Cost Recovery. All costs incurred for cleaning the sewer line to remove FOG buildup caused or contributed to by an FSE shall be reimbursed to the city by the FSE. Factors for determining responsible parties for cost recovery charges include the FSEs that are discharging into the affected sewer line, the presence of interceptors or alternative pretreatment in the FSE, proper maintenance of grease interceptors by the FSE, implementation of BMPs, and any waivers or variances granted. (o) Drawing Submittal Requirements. At the time of obtaining a FOG Wastewater Discharge Permit or upon request by the Director: (1) FSEs may be required to submit copies of design and as-built facility site plans, mechanical and plumbing plans and details to show all sewer locations and connections. The documents shall be in a form acceptable to the Director for review of existing grease interceptors, monitoring facilities, metering facilities and operating procedures. The review of plans and procedures shall in no way relieve the FSE of the responsibility to modify the facilities or procedures in the future, as necessary to produce an acceptable discharge and to meet the requirements of this FOG Control Program. (2) FSEs may be required to submit a schematic drawing of the grease interceptor or alternative pretreatment, piping and instrumentation diagram, and wastewater characterization report. (3) At the Director's discretion, all drawings and/or reports may be required to be prepared by a California Registered Civil, Chemical, or Electrical Engineer. (p) Gravity Grease Interceptor Requirements. Any FSE that is required to provide FOG pretreatment shall install operate and maintain an approved type and properly sized gravity grease interceptor, or other grease interceptor authorized under an approved variance, necessary to maintain compliance with the purpose of the FOG Control Program. (1) Approved gravity grease interceptor sizing and installation shall conform to the latest approved edition of the California Uniform Plumbing Code. (2) Gravity grease interceptors shall be constructed in accordance with the design approved by the Director and shall have a minimum of two compartments with fittings designed for grease retention. (3) Gravity grease interceptors shall be installed at a location where it shall be at all times easily accessible for inspection, cleaning and removal of accumulated grease. (i) Gravity grease interceptors may not be installed in any part of the building where food is handled. (ii) If a location is not available on the property of the FSE, a street encroachment permit may be requested to authorize installation of a gravity grease interceptor in a public access area such as the street or sidewalk area. (iii) There will be no obstruction from landscaping or parked vehicles, with the exception of parked vehicles in a public access area as granted through a street encroachment permit. (4) Access structures, with a minimum diameter of twenty-four (24) inches, shall be provided over each gravity grease interceptor chamber and sanitary tee. The access structures shall also have readily removable covers to facilitate inspection, grease removal and wastewater sampling activities. (5) The original design of the gravity grease interceptor shall not be modified unless the manufacturer recommends the modification in writing. (i) Any modification will be at the Food Service Establishment's expense. (ii) The city is not liable for any non-compliance as a result of any modification. (q) Gravity grease Interceptor Maintenance Requirements. Gravity grease interceptors shall be maintained in efficient operating condition by periodic complete removal of all contents of the devices including wastewater, accumulated FOG, floating materials, sludge and solids. (1) No FOG that has accumulated in a grease interceptor shall be allowed to pass into any sewer lateral, sewer system, storm drain, or public right of way during maintenance activities. (2) Food Service Establishments that are located in an area that is considered to be a hot spot will be required to submit data and information necessary to establish a maintenance frequency for their gravity grease interceptor. (3) The maintenance frequency for all Food Service Establishments with a gravity grease interceptor shall be determined in one of the following methods: (i) Gravity grease interceptors shall be fully pumped out and cleaned at a frequency such that the combined FOG and solids accumulation does not cause or have the potential to cause a sanitary sewer overflow. Regardless, the interval between cleaning shall not exceed six (6) months. (ii) The owner/operator of a Food Service Establishment may submit a request to the Director asking for a change in the maintenance frequency at any time. The Food Service Establishment has the burden of responsibility to prove that the change reflects actual operating conditions based on the average FOG accumulation over time. The Food Service Establishment must also show that it is in full compliance with the conditions of its FOG Wastewater Discharge Permit and this section. Upon approval by the Director, the FOG Wastewater Discharge Permit will be modified accordingly to reflect the change in maintenance frequency. (iii) If the gravity grease interceptor contains, at any time, FOG and solids accumulation that causes a sanitary sewer overflow, the Food Service Establishment shall be required to have the gravity grease interceptor serviced immediately so that all FOG, sludge and other materials are completely removed from the interceptor. If necessary, the Food Service Establishment may be required to increase the maintenance frequency of the gravity grease interceptor from its current frequency. (4) Wastewater, accumulated FOG, floating materials, sludge, solids, and other materials removed from the gravity grease interceptor shall be disposed offsite properly by licensed waste haulers in accordance with federal, state, and/or local regulations. (r) Hydro-mechanical Grease Interceptor Requirements. Hydro-mechanical grease interceptors may be authorized by the Director through a variance under Subsection (k) with the following conditions: (1) Hydro-mechanical grease interceptors shall be installed in waste lines leading from drains, sinks and other fixtures or equipment where grease may be introduced into the sewer system in quantities that can cause blockage. (2) Hydro-mechanical grease interceptors shall be properly sized and installed in accordance with the latest approved edition of the California Uniform Plumbing Code. (3) The original design of the hydro-mechanical grease interceptor shall not be modified unless the manufacturer recommends the modification in writing. (i) Any modification will be at the FSE's expense. (ii) The city is not liable for any non-compliance as a result of any modification. (4) Hydro-mechanical grease interceptors shall be maintained in efficient operating conditions by removing accumulated grease. The interval between cleaning will be established by the Director. Baffles shall be removed and cleaned during the maintenance process, when applicable. (5) Hydro-mechanical grease interceptors shall be kept free of all food residues and any FOG waste removed during the cleaning and scraping process. (6) Hydro-mechanical grease interceptors shall be inspected periodically to check for leaking seams and pipes and for effective operation of the baffles and flow regulating devices. (7) Hydro-mechanical grease interceptors and their baffles shall be maintained free of all caked on FOG and waste. (8) Dishwashers and food waste disposal units shall not be connected to or discharged into any hydro-mechanical grease interceptor. (9) The temperature of any water entering a hydro-mechanical grease interceptor shall not exceed 140° F (60° C). (s) Monitoring Requirements. (1) The Director may require, through the FOG Wastewater Discharge Permit or at any time, an FSE to construct and maintain in proper operating condition, at the FSE's sole expense, flow monitoring, constituent monitoring, and/or sampling devices. (2) The location of monitoring or metering devices shall be subject to approval by the Director. (3) At all times, FSEs shall provide immediate, clear, safe and uninterrupted access to authorized representatives of the city to all monitoring and metering devices. (4) FSEs may be required by the Director to submit waste analysis plans, contingency plans, and meet other necessary requirements to ensure proper operation and maintenance of any grease interceptor and compliance with this section, (s) Record Keeping Requirements. FSEs shall keep all records, including manifests, receipts and invoices of all cleaning and maintenance of grease interceptors. All records shall be made available to authorized representatives of the city upon request. In addition to the above mentioned documents, records include logbooks of maintenance activity, BMPs and employee training, sampling data, spill reports, line cleaning reports, and any other information deemed appropriate by the Director to ensure compliance with the FOG Control Program and this section.
(Added Ord. 2008-33, § 12, eff. 6-22-08; Am. Ord. 2019-021, § 3, eff. 9-28-19).
Ask a question about Fresno law
Corpus searches the Fresno sections it holds and shows the ones that match, with their citations. Free, no sign-in.
