For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 15.40.060 — ACCESS AND CIRCULATION STANDARDS

Fullerton, California, Code of Ordinances (2026 S-1: Local legislation current through Ord. 3352) · Fullerton Municipal Code § 15.40.060

Corpus is an independent public-information project, not the official City of Fullerton website. Stable reference: corpuslaw.us/code/6b59c6cb-12f9-496b-9356-1ab93ce22883

§ 15.40.060 ACCESS AND CIRCULATION STANDARDS.

(A) Access. (1) All required parking spaces shall have access to a public street or alley. (2) An adequate driveway “throat” shall be provided from the public street, unencumbered by parking spaces, turnaround areas or control gates, subject to the approval of the Director of Public Works. (B) Driveway and drive aisle standards. (1) One-way and two-way driveways and drive aisles shall have minimum width in accordance with Tables 15.40.060(A) and (B) and Figures 17 and 18. (2) Driveways and/or turnaround aisles serving ten or more parking spaces shall not be dead-ended unless a turnaround or back-up area is provided to the satisfaction of the Director of Development Services. Figure 16 represents the preferred layout for a turnaround area. [image omitted; see the official code] (3) Turnaround aisles shall be designed in accordance with Tables 15.40.060(A) and (B) and Figures 17 and 18, or as otherwise required by the Director of Development Services. Table 15.40.060(A) Parking and Drive Aisle Minimum Design Standards for One-Way Drive Aisle Stall Angle | Standard Size Stalls (9’ x 19’) | Compact Size Stalls (8’ x 16’) Bay Width | Row Width | Drive Aisle Width | Bay Width | Row Width | Drive Aisle Width Single Loaded | Double Loaded | Single Loaded | Double Loaded Table 15.40.060(A) Parking and Drive Aisle Minimum Design Standards for One-Way Drive Aisle Stall Angle | Standard Size Stalls (9’ x 19’) | Compact Size Stalls (8’ x 16’) Bay Width | Row Width | Drive Aisle Width | Bay Width | Row Width | Drive Aisle Width Single Loaded | Double Loaded | Single Loaded | Double Loaded 0 degrees | 21.00 | 30.00 | 9.00 | 12.00 | 20.00 | 28.00 | 8.00 | 12.00 30 degrees | 29.30 | 46.60 | 17.30 | 12.00 | 26.93 | 41.86 | 14.93 | 12.00 45 degrees | 33.80 | 53.60 | 19.80 | 14.00 | 30.97 | 47.94 | 16.97 | 14.00 60 degrees | 38.96 | 59.92 | 20.96 | 18.00 | 35.86 | 54.72 | 17.86 | 18.00 90 degrees | 44.00 | 63.00 | 19.00 | 25.00 | 41.00 | 57.00 | 16.00 | 25.00 Notes to Table: All measurements are in feet. Table 15.40.060(B) Parking and Drive Aisle Minimum Design Standards for Two-Way Drive Aisles Stall Angle | Standard Size Stalls (9’ x 19’) | Compact Size Stalls (8’ x 16’) Bay Width | Row Width | Aisle Width | Bay Width | Row Width | Aisle Width Single Loaded | Double Loaded | Single Loaded | Double Loaded Table 15.40.060(B) Parking and Drive Aisle Minimum Design Standards for Two-Way Drive Aisles Stall Angle | Standard Size Stalls (9’ x 19’) | Compact Size Stalls (8’ x 16’) Bay Width | Row Width | Aisle Width | Bay Width | Row Width | Aisle Width Single Loaded | Double Loaded | Single Loaded | Double Loaded 0 degrees | 29.00 | 38.00 | 9.00 | 20.00 | 28.00 | 36.00 | 8.00 | 20.00 30 degrees | 37.30 | 54.60 | 17.30 | 20.00 | 34.93 | 49.86 | 14.93 | 20.00 45 degrees | 39.80 | 59.60 | 19.80 | 20.00 | 36.97 | 53.94 | 16.97 | 20.00 60 degrees | 45.96 | 66.92 | 20.96 | 25.00 | 42.86 | 61.72 | 17.86 | 25.00 90 degrees | 44.00 | 63.00 | 19.00 | 25.00 | 41.00 | 62.00 | 16.00 | 25.00 Note to Table: All measurements are in feet. [image omitted; see the official code] (C) Loading docks. Load docks and truck-maneuvering space shall not encroach upon mandatory landscaped areas or upon other required parking spaces and shall be screened from public view. (Ord. 2982, passed - -2001; Ord. 3066, passed - -2005)

Ask a question about Fullerton law

Corpus searches the Fullerton sections it holds and shows the ones that match, with their citations. Free, no sign-in.