For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 9.08.040.010 — Single-Family Residential—General Requirements

Code of Ordinances, City of Garden Grove, California (Code 2026-08-11) · Garden Grove Code of Ordinances § 9.08.040.010

Corpus is an independent public-information project, not the official City of Garden Grove website. Stable reference: corpuslaw.us/code/0357b086-f5bf-4037-ab76-1a2a15005db6

§ 9.08.040.010: Single-Family Residential—General Requirements.

The following general requirements pertain to all residential zoned property and shall be determined to be minimal requirements, unless stated as maximum by this code: A. Setbacks. 1. Every required setback shall be open and unobstructed from the ground to the sky, aside from landscaping, or unless otherwise specified. 2. No setback or open space provided around any building for the purpose of complying with the provisions of this section shall be considered as providing a setback or open space for any other building or on which a building is to be erected. B. Modification of Required Front Yard Setbacks on Lots Fronting on the Curves of Cul-de-Sacs or Knuckles. 1. The required front setbacks may be reduced by one-half where: a. The street pattern of a subdivision includes lots fronting upon cul-de-sac turnarounds or knuckle widenings at right angles or approximate right-angle turns in a street; and b. Where cul-de-sac or knuckle designs create a greater street width resulting in reduced depth of the lots fronting the cul-de-sac or knuckle widening. 2. The required front setback may be reduced to not less than one-half of the required front setbacks for the zone in which the property is located when the lot line that represents the depth of the lot intersects any portion of the arc formed by the constant radius of a cul-de-sac or knuckle. C. Permitted Intrusions. The following intrusions may project into any required setback a maximum of two feet. 1. Cornices; 2. Eaves; 3. Belt courses; 4. Sills; 5. Buttresses; 6. Planter boxes; 7. Masonry planters; 8. Guard railings; 9. Chimneys. D. Lot Area Regulations. 1. Lot area shall not be reduced. No lot area shall be reduced or diminished so that the lot area, setbacks or other open spaces shall be less than prescribed for the zone in which it is located. 2. Substandard Lots. When a lot has less than the minimum required area or width as set forth in the development standards of each zone, or in a site plan, and was of record on November 17, 1960, the lot shall be deemed to have complied with the minimum required lot area or width as set forth in the zone or site plan. E. Height Limits. 1. Residential buildings shall comply with the requirements shown in the Table of Building Requirements but in no case shall be higher than 35 feet, unless otherwise specified below. 2. Fire or parapet walls, skylights, towers, flagpoles, chimneys, smokestacks, radio masts and similar structures may be erected above the height limits prescribed if done so in conjunction with a development plan or the filing of a conditional use permit. 3. No penthouses or roof structures or any space above the height limit prescribed for the zone and area district in which the building is located shall be allowed for the purpose of providing additional habitable floor spaces, except for the following: Usable floor space may be provided above allowable heights for religious institution and public, private or parochial schools when employed as a unique structure, tower or spire, subject to a conditional use permit. F. Placement of Buildings. Placement of buildings on any lot shall conform to the following: 1. No habitable portion of a building shall occupy any portion of any required setback, except as provided for in the development standards addressing permitted intrusions. 2. Any garage or carport that opens directly to any street or alley shall observe a setback of not less than 20 feet unless otherwise permitted by this title. 3. When a garage or carport abuts an alley and the access to the garage or carport is perpendicular to the alley, the building shall not be constructed closer than 20 feet to the centerline of the alley and shall maintain a minimum setback of five feet from the property line. G. Mechanical Equipment, Metering Devices. All roof and ground mounted mechanical equipment and metering devices shall be screened from view from either on or off the property. Ground-mounted mechanical equipment, including, but not limited to, water heaters, heating, cooling or ventilating equipment, swimming pool or spa heaters, pumps or filters, may be permitted to be located in a side yard setback on any property improved with a single-family residence, provided that the equipment is screened from view from all public rights-of-way. If required by manufacturer's specifications, equipment may be installed within exterior equipment enclosures. All equipment enclosures, including any flues, accessories, or other appurtenances, shall be painted to match the main house. If the equipment is to be located between a structure and the property line, an unobstructed path at least three feet wide shall be provided between the equipment and the property line.

( 2947 , 11/28/2023 )

Ask a question about Garden Grove law

Corpus searches the Garden Grove sections it holds and shows the ones that match, with their citations. Free, no sign-in.