§ 9.12.040.040 — Special Requirements—Duplex and Triplex in R-2 and R-3 Zones
Code of Ordinances, City of Garden Grove, California (Code 2026-08-11) · Garden Grove Code of Ordinances § 9.12.040.040
Corpus is an independent public-information project, not the official City of Garden Grove website. Stable reference: corpuslaw.us/code/55bcef98-f34b-415e-96fd-063f89b80aaf
§ 9.12.040.040: Special Requirements—Duplex and Triplex in R-2 and R-3 Zones.
The following standards shall be required for the development of a two- or three-unit residential project on an R-2 or R-3 zoned property. The development can be designed to provide attached and/or detached units. Each development shall comply with the general requirements as contained in Sections 9.12.040.010 and 9.12.040.020 for those standards that are not specified herein. Unless otherwise specified within this section, all the development standards shall be deemed as minimum requirements. A. Lot Width Requirements. The minimum lot width for new construction shall be 60 feet. B. Maximum Stories and Building Height. 1. Main structure(s): two stories with a maximum building height of 30 feet. 2. Detached garage or accessory structure(s): one story with a maximum building height of 17 feet. C. Maximum number of sleeping rooms per unit: four. D. Lot Coverage. The maximum lot coverage shall not exceed 50%. The lot coverage shall include all buildings and structures (primary and accessory), covered porches and patios, and covered parking areas. E. Main Building Setbacks. 1. The following minimum building setbacks shall be observed from the property lines. Detached garages and accessory structures shall comply with the setbacks contained in subsection F. The required setbacks shall be maintained open and unobstructed from the ground to the sky, except for the permitted intrusions established in subsection F. Front: | 20′-0″ Interior Side: 1st Floor | 5′-0″ 2nd Floor | 10′-0″ Street Side: 1st Floor | 10′-0″ 2nd Floor | 15′-0″ Rear: 1st Floor | 10′-0″ 2nd Floor | 15′-0″ If the property abuts R-1 zoned properties: 1st Floor | 15′-0″ 2nd Floor | 20′-0″ Diagrams Indicating Building Setbacks 2. Diagram indicating setbacks for a duplex or triplex on an R-2 or R-3 zoned parcel located contiguous to an R-2 or R-3 zoned parcel. [image] 3. Diagram indicating setbacks for a duplex or triplex on an R-2 or R-3 zoned parcel located contiguous to an R-1 zoned parcel. [image] F. Detached Garages and Accessory Structures Setbacks. The following setbacks shall be observed for detached garages and accessory structures: 1. Distance between detached garages and interior side and/or rear property lines: a. Minimum five feet if the property is located adjacent to an R-1 zone property. b. Detached garages, located on a property that is adjacent to any multiple-family, commercial, industrial or open space zoned property, may be designed to have a zero setback to any interior and/or rear property line provided that the width of the detached garage shall not exceed 50% of the width of the property line. 2. Any attached or detached garage that opens directly to any street or alley shall observe a minimum setback of 20 feet from the property line. 3. Distance between detached accessory structures, including, but not limited to, storage sheds, freestanding patio covers, etc., and interior side and/or rear property lines: five feet. 4. Distance between detached accessory structures, including, but not limited to, storage sheds, freestanding patio covers, etc., and street side property lines: 10 feet. 5. Garages or accessory structures that are attached to any portion of the main residence shall comply with the setback requirements of subsection E. 6. At no time shall an accessory structure, such as a patio cover or storage shed, be attached to any detached garage. G. Permitted Intrusions. The following intrusions shall be permitted into the required setback areas: 1. The permitted intrusions as contained in Section 9.12.040.010.C, Permitted Intrusions. 2. Architectural projections with no floor area, including, but not limited to, bay windows, pilasters, and chimneys may project up to two feet into the setbacks. 3. Entry porches for units located along the front setback may encroach up to five feet into the required front setback area. The width of the porch shall not exceed 50% of the width of the unit located along the front setback. H. Dwelling Entries and Covered Entries. 1. Each individual dwelling unit shall have a main entry that is clearly defined by use of a stoop, framed doorway, or covered doorway that is recessed from the building façade a minimum depth of three feet. At least one unit shall have the main entry oriented directly toward the adjacent street. 2. All front entry doors that are designed to be parallel to any drive aisle and/or open parking area shall maintain a minimum separation of 10 feet from the drive aisle and/or open parking area. I. Separation of Buildings, Accessory Buildings, Parking Areas and Vehicle Drive Aisles. Each development shall comply with the following minimum separation distances. 1. Distance between detached units: eight feet. 2. Distance between the drive aisle and the unit (including entry porches/ covered patios): five feet. Exception: The required separation may be reduced to less than five feet, but to a distance no less than required to comply with applicable fire code standards, for properties that are preserving an existing dwelling unit but cannot provide the required separation due to the placement of the existing unit. 3. Distance between guest parking areas and the unit (including porches/covered patios): five feet. 4. Distance between detached garages and/or detached accessory structures and the unit (including entry porches and covered patios): five feet. 5. Distance between detached accessory buildings: five feet. J. Access and Circulation. Each development shall be designed to provide on-site vehicular access, circulation, back-up, and turn-around areas that comply with all the applicable standards of this code. 1. Vehicular Access. All projects shall maintain the following minimum drive aisle width: a. New developments that are accessed from a shared drive approach shall maintain a minimum 25-foot-wide drive aisle; however, the width may be reduced to 20 feet where the lot frontage on which the drive aisle is located is less than 80 feet in width. b. In situations where an existing unit(s) will remain on the property and both the existing unit(s) and new unit(s) will be accessed from the existing drive aisle, and where the width of the existing drive aisle cannot be increased in width due to the placement of the existing unit(s), the width of the shared drive aisle may be reduced to no less than 16 feet. c. Required Landscaping. All projects with a shared drive aisle shall provide a landscape planter with a minimum width of five feet located along the drive aisle and the closest adjacent property line; however, the width of the landscape planter may be reduced less than five feet under the following circumstances: i. To accommodate vehicle back-up and/or turn around areas consistent with Public Works Department, Engineering Division standards, or ii. For properties that have a lot width of less than 60 feet, or iii. For properties that will preserve an existing dwelling unit but cannot provide the required landscaping due to the placement of the existing unit. 2. Vehicular Circulation. a. Vehicular Back-Up. Based on the site's location and the proposed project design, a minimum vehicle back-up area of 25 feet or greater may be required, as determined by the City Engineer for conformance with City standards, to allow vehicles to maneuver safely on and off the site in a manner that does not interfere with traffic flow on the adjacent street. b. Vehicular Turn-Around. Through the director's review and/or building permit review process, the City Engineer will determine if a vehicular turn-around will be required to ensure that vehicle movements on and off the site will not interfere with traffic flow on the adjacent street, consistent with adopted City standards. c. Required Parking and Enclosed Garages. Each development shall comply with the minimum parking requirements for multiple-family developments as contained in Section 9.12.040.180, Parking Spaces Required. 3. The required parking shall be provided in the form of a two-car enclosed garage for each unit, and the guest parking may be covered or uncovered. The covered parking space(s) shall be designed and constructed to match the architectural style and colors of the buildings they serve. 4. Guest parking spaces may be located in front of an enclosed garage, provided that the parking spaces do not extend into any required drive aisle or into the required back-up or turn-around areas, and do not encroach, block, or impede access to the garage or parking area of the other unit(s). 5. Guest parking spaces located within the interior of the lot shall have a minimum depth of 19 feet and a minimum width of nine feet. When a guest parking space is covered or adjacent to a wall, the width of the parking shall be 10 feet. 6. Each enclosed garage shall maintain a minimum interior parking area of 20 feet by 20 feet. No storage cabinets or mechanical equipment, including, but not limited to, water heaters, utility sinks, or washers and dryers, shall encroach into the required parking area. 7. All garages shall be equipped with automatic roll-up garage door openers that shall be maintained in an operable condition at all times. 8. Each garage shall be maintained to allow the required number of parking spaces for vehicle parking to be available within the enclosed garage at all times. K. Open Space. A private recreation area shall be provided for each unit and shall comply with the following standards: 1. Each unit shall provide a minimum and continuous private recreation area of at least 225 square feet and with minimum interior dimensions of 15 feet by 15 feet. Exception: The dimension of the private recreation area may be reduced to no less than 10 feet for properties that have a lot width of less than 60 feet, provided that the required total net recreation area is maintained with the reconfiguration. 2. The private recreation area shall be open and unobstructed from the ground to the sky. 3. The private recreation area shall be conveniently located next to the unit, and accessed directly from a public area, such as a living room, family room, dining area, or kitchen. 4. The private recreation area may be located within the interior side, street side, or rear setback areas. 5. Private recreation areas located adjacent to any street or alleyway shall be screened from view from a public right-of-way with a six-foot high decorative masonry wall. The wall shall maintain a minimum three-foot setback from any side street property line for landscaping purposes and shall comply with all visibility requirements as contained in Section 9.12.040.140, Wall, Fence and Hedges. L. Architectural Compatibility Between New and Existing Units. If a development is designed to preserve any existing unit(s) on the property, the architectural style and design features of the existing residential unit and each new residential unit, attached or detached addition, or accessory structure shall match one another, as provided below: 1. The type, pitch, color, material, and texture of the roof and eave details of a new residential unit, an attached or detached addition, or accessory structure shall be the same as the existing residential unit. 2. The color, material, and texture of all building walls, windows, and doors of a new residential unit, an attached or detached addition, or accessory structure shall be the same as the existing residential unit. M. Building Design. Each project shall be designed to include architectural design approaches that include all the following elements: 1. Rooflines that have at least two changes in orientation and/or pitch. 2. For buildings that have a front façade greater than 30 feet in length, the building shall have a break in the façade plane of a minimum depth of three feet for at least every 30 feet of frontage. 3. Architectural accents and materials shall reflect a consistent architectural style. This shall apply to roof forms and materials, window shapes, accent materials, decorative columns, porches, balconies, and decorative trim on all windows and doors. 4. All building façades shall contain architectural detailing consistent with the architectural style used. At least three treatments from the following list shall be used consistently on all building façades: a. Use of two building materials and finishes; b. Use of at least two complementary paint colors; c. Windows that are recessed at least six inches; d. Window surrounds of at least four inches in width that are consistent with the architectural style used on the building; e. Projecting/bay windows; f. Window shutters; g. Exterior soffit and fascia boards. N. Storage Facilities. Each dwelling unit shall provide a minimum 120 cubic feet of private and secure storage space. Such space may be included either interior to the dwelling unit, within individual required parking areas in a manner that does not interfere with required parking spaces, or within an aggregated common storage area. Bedroom closets and cupboard space located within the unit shall not count toward meeting this requirement O. Laundry Facilities. Each dwelling unit shall have a laundry space located within the unit or within the private garage for that unit that is equipped with washer and dryer hook-ups. If the laundry facilities are located within the enclosed garage, the laundry equipment shall not encroach into the required interior garage parking area of 20 feet by 20 feet. P. Refuse Storage Areas. All developments shall provide each unit with the appropriate number of trash containers as required by the Garden Grove Sanitary District, and shall comply with the following: 1. Trash containers shall be stored within designated storage areas only and not within the garage parking area. 2. The placement of trash containers for pick-up, and the duration of time prior to and after trash collection of those trash containers, shall be subject to the Garden Grove Sanitary District requirements. 3. The area required for each container shall be a minimum of 38 inches by 38 inches. 4. The trash areas shall be paved and accessed by a walkway that allows tenants for ease of taking trash containers to and from the street. 5. If it is determined that a trash enclosure is required to serve the property instead of individual trash containers based on the property's location (i.e., located along a major arterial), the property shall comply with the refuse storage requirements as contained in Section 9.12.040.020, Refuse Storage Areas. Q. Water Heaters. Each dwelling unit shall have a separate hot water heater, or the entire development may be provided with a centralized circulation water heater system to serve all dwelling units on the property consistent with building code requirements. No exterior water heater enclosures shall be permitted. Water heaters may be substituted with tankless water heaters, provided all building codes are complied with. R. Utility Meters. All above-ground utility meters, including, but not limited to, water meters, gas meters, and irrigation equipment, shall be placed outside of the required front setback area. Planned locations shall be indicated on-site plans. All above-ground utility meters shall be completely screened from view from adjacent public rights-of-way and the immediate adjacent property facing the utility meters. Screening shall consist of landscaping, an architectural feature integrated into the building façade, a wall, or a fence. S. Privacy Provisions. Second-story windows, balconies, and decks on side and rear building sides shall be located to avoid direct views from those windows, balconies, and decks into any immediately opposite windows and private recreation areas of residential dwelling units on adjacent properties. Where second-story windows are oriented toward an adjacent property's private recreation area, one or more of the following measures shall be provided: 1. High windows with a minimum sill height of six feet, as measured from the finished floor. 2. View-obscuring treatment such as wing walls. 3. Obscure, opaque, or frosted fixed (non-slider) windows. 4. A row of screening/canopy trees evenly spaced shall be placed along the property line(s), which shall be of a minimum height that blocks any direct views. Screening/canopy trees shall be maintained in perpetuity. T. Landscaping. All setback areas and all areas not developed with walkways, parking, drive aisle, and private recreation areas shall be fully landscaped and irrigated. All development shall comply with the landscaping and irrigation requirements contained in Chapter 9.16 of this title. U. Perimeter Block Walls. Each development shall provide a masonry perimeter wall with a minimum height of six feet, as measured from the highest point of the finished grade next to the wall, that shall comply with the following: 1. All perimeter fencing shall comply with the requirements contained in Section 9.12.040.140, Walls, Fences and Hedges. 2. New walls or fences shall not exceed a height of seven feet as measured from the finished point of grade next to the wall. At no time shall the overall height of the wall, as measured from adjacent neighbor's finished grade, exceed eight feet in height, except to the extent required by the City to comply with applicable site grading or water quality standards. 3. Fences or walls located within the front yard areas or adjacent to driveways shall not exceed 36 inches in height. 4. Perimeter walls located along any side street shall maintain a minimum setback of three feet from the property line. The area between the wall and property line shall be landscaped with tall growing shrubs or trailing vines to deter graffiti and shall be automatically irrigated. 5. The property owner shall work with the adjoining property owners in designing and constructing the perimeter block walls to avoid the use of double walls. If the property owner cannot obtain approval from the adjoining property owners, the property owner shall construct the new wall with a decorative cap to be placed between the new and the existing wall. 6. All walls shall be designed to ensure proper vision clearance for cars entering or leaving the driveway and parking areas. No wall or fence shall cause an exceedance of the applicable site distance standards set forth in City of Garden Grove Traffic Engineering Policy TE 13 or in any revised or updated standard or policy promulgated by the CIty. 7. If a six-foot high perimeter masonry wall already exists on site or on an adjacent property, no such wall shall be required for the new development. 8. Street facing perimeter block walls, whether new or existing, shall be decorative and utilize stucco finish, slump stone or split-face block, and shall include trailing vines, hedges planted along the base of the exterior face, or other landscaping treatments that deter graffiti. 9. No security gates will be allowed unless the development complies with Section 9.12.040.200.B.3.
( 2939 § 3, 2022 ; 2967 , 8/12/2025 )
Ask a question about Garden Grove law
Corpus searches the Garden Grove sections it holds and shows the ones that match, with their citations. Free, no sign-in.
