§ 9.18.090.070 — Neighborhood Mixed Use Zone (NMU) Development Standards
Code of Ordinances, City of Garden Grove, California (Code 2026-08-11) · Garden Grove Code of Ordinances § 9.18.090.070
Corpus is an independent public-information project, not the official City of Garden Grove website. Stable reference: corpuslaw.us/code/2a6253f3-5aee-421e-bec0-0cc97a7a4f06
§ 9.18.090.070: Neighborhood Mixed Use Zone (NMU) Development Standards.
A. General. In addition to the other applicable requirements of this chapter, the provisions of this section apply to proposed development in the NMU zone. Table 9.18-5 (Development Standards for the Neighborhood Mixed Use Zone) sets forth the general development standards applicable to all development in the NMU zone. Table 9.18-5Development Standards for the Neighborhood Mixed Use Zone Development Standards | Neighborhood Mixed Use Zone (NMU) Minimum Lot Size | Minimum area and width for new lots. When a lot has less than the minimum required area or width as set forth in the development standards for the zone in which it is located and was of record on November 12, 1960, the lot shall be deemed to have complied with the current minimum required lot area or width. Minimum Area | 15,000 sf Minimum Width | 75 ft Minimum Width (Corner Lot) | 75 ft Maximum Density/Intensity Maximum Commercial Floor Area Ratio (FAR) | 0.5 Maximum Residential Density (units/acre) | 24 units/acre Residential development requires an on-site commercial development component of a minimum 0.2 FAR.Stand-alone multiple-family residential development in the NMU zone is only permitted on sites that do not have access to a principal, major, primary, or secondary arterial street and is not required to include a pedestrian plaza area. Setbacks | Minimum setbacks required. See Section 9.18.100 for setback measurement, allowed encroachments and projections into setbacks, and exceptions to setbacks. Front | Minimum 15 ft Side | None required Corner Side | Minimum 10 ft Rear | None required unless abutting a residentially zoned lot; minimum 10 ft when abutting a residentially zoned lot. See Section 9.18.100. Maximum Height | Maximum building height shall not exceed height limit in feet or stories. See also Section 9.18.100 for rear and side yard encroachment plane requirements which may restrict heights adjacent to a residentially zoned lot. 50 ft or four stories, whichever is less Lot Coverage Minimum Lot Coverage | Not applicable Maximum Lot Coverage | Not applicable B. Maximum Gross Building Footprint. In the NMU zone, the gross building footprint of any structure at the ground level shall not exceed 40,000 square feet of contiguous floor area. C. Pedestrian-Oriented Plaza Requirement. Each project in the NMU zone shall provide a pedestrian plaza, except for projects that are 100% residential, in which case the plaza shall not be required. The purpose of the pedestrian-oriented plaza is to provide a place for passive recreation, public gathering, landscape amenities, display of public art, and similar uses that enhance the appearance and function of development and integrate multiple uses on a site. For a building that is constructed with orientation toward the street, the pedestrian-oriented plaza shall be in the form of a boulevard garden plaza along the front setback and shall conform to the standards of Section 9.18.090.020.F (Boulevard Garden Plaza Requirement). For other development approaches and types, the plaza shall be a pedestrian plaza that connects the various uses/buildings on the site. In particular, for sites at Brookhurst Street and Chapman Avenue, pedestrian pathways in the form of sidewalks and crosswalks shall be used to connect uses across the street from each other. 1. Permitted Uses. The required pedestrian plaza may consist of landscaped and paved areas, outdoor dining, public art display, fountains, or similar uses and amenities permitted in the applicable zone. A minimum of three types of improvements and/or amenities shall be provided. 2. When the plaza is interior to a property, nonvehicular vending kiosks may be permitted. 3. Minimum Area. The pedestrian plaza shall comply with the minimum area requirements set forth in Table 9.18-6 (Minimum Pedestrian Plaza Area in the NMU Zone). Table 9.18-6Minimum Pedestrian Plaza Area in the NMU Zone Right-of-Way Frontage Length | Minimum Plaza Area Less than 150 feet | 600 sf 150—300 feet | 1,000 sf More than 300 feet | 1,500 sf 4. Shape and Minimum Dimensions. The required plaza area shall have minimum dimensions of 10 feet in width and 10 feet in length. The required area may be split into no more than two contiguous areas. 5. Location. The plaza area may be located anywhere on site, but shall be accessible to the public via pedestrian accessways of a minimum five-foot width. 6. Other Requirement. The plaza area shall not be enclosed or obstructed by fencing or walls, except as required for permitted outdoor dining areas abutting a public right-of-way.
( 2814 , 2012 ; 2925 § 5, 2021 ; 2939 § 3, 2022 )
Ask a question about Garden Grove law
Corpus searches the Garden Grove sections it holds and shows the ones that match, with their citations. Free, no sign-in.
