§ 9.48.040 — Exceptions to Undergrounding Requirements
Code of Ordinances, City of Garden Grove, California (Code 2026-08-11) · Garden Grove Code of Ordinances § 9.48.040
Corpus is an independent public-information project, not the official City of Garden Grove website. Stable reference: corpuslaw.us/code/c52bb51e-c74c-4996-aece-e0205d866497
§ 9.48.040: Exceptions to Undergrounding Requirements.
Undergrounding shall not apply to: A. Poles or electroliers used exclusively for street lighting. B. Utility facilities exempted from undergrounding by the Public Utilities Commission or applicable federal, state, or local law. C. Utility facilities that do not provide service to the property or structure being developed, redeveloped, or subdivided. D. Temporary poles, overhead wires, and associated structures used, or to be used, in conjunction with construction projects. E. Existing poles, overhead wires, and associated structures used for the transmission of electrical energy at nominal voltages 66,000 volts or greater if it is determined by the City Engineer that such undergrounding is not technically or economically feasible. F. Antennae, associated equipment, and supporting structures used by a utility company for furnishing communication services. G. Equipment appurtenant to or associated with underground facilities, such as surface mounted transformers, meter cabinets, pedestal-mounted terminal boxes, and concealed ducts, which, in the determination of the City Engineer, should be placed above ground for technical or public safety reasons. H. Temporary poles, overhead wires, and associated structures for emergency service installed and maintained for a period not to exceed 10 days, unless a longer period is approved in writing by the City Manager or designee. I. Utility facilities the undergrounding of which the City Engineer determines would be impractical or technically infeasible due to physical constraints such as topography, soil, or other existing conditions. J. Existing above-ground utility facilities, where the project is limited to the construction, enlargement, alteration, or rehabilitation of one single-family dwelling. The developer shall underground all new utility facilities associated with the project. K. Existing above-ground utility facilities, where the project is limited to the enlargement, alteration, or rehabilitation of buildings or structures other than a single-family dwelling where the enclosed floor area is not increased by more than 25%. The developer shall underground all new utility facilities associated with the project.
( 2775 § 1, 2010 )
Ask a question about Garden Grove law
Corpus searches the Garden Grove sections it holds and shows the ones that match, with their citations. Free, no sign-in.