§ 9.54.040 — ADU Requirements
Code of Ordinances, City of Garden Grove, California (Code 2026-08-11) · Garden Grove Code of Ordinances § 9.54.040
Corpus is an independent public-information project, not the official City of Garden Grove website. Stable reference: corpuslaw.us/code/a5323c12-ce09-44e5-ab38-52453a11884f
§ 9.54.040: ADU Requirements.
A. Development Standards. Except as modified by this section or as otherwise provided by state law, an ADU shall conform to the development standards applicable to the lot on which it is located as set forth in this title and/or in an applicable specific plan or planned unit development ordinance or resolution. Pursuant to Sections 9.12.040.030 and 9.18.110.040, lots located in multiple-family residential and mixed-use zoning districts that are improved with single-family residential uses are subject to certain single-family residential development standards. Notwithstanding the foregoing, when the application of a development standard related to floor area ratio, front setbacks, building separation, lot coverage, open-space, or minimum lot size would prohibit the construction of an attached or detached ADU of at least 800 square feet, such standard shall be waived to the extent necessary to allow construction of an ADU of up to 800 square feet. B. Unit Size. 1. Minimum Size. An ADU shall be at least the following minimum sizes based on the number of bedrooms provided: a. Efficiency units: 150 square feet. b. Studio: 220 square feet. c. One bedroom: 500 square feet. d. Two or more bedrooms: 700 square feet. 2. Maximum Size. a. Attached ADUs. The total floor area of an attached ADU shall not exceed the following: i. Studio or one bedroom: 850 square feet or 50% of the floor area of the primary dwelling unit, whichever is less; provided, however, that if the size of the primary dwelling unit is less than 1,600 square feet, an attached ADU may have a total floor area of up to 800 square feet. ii. Two or more bedrooms: 1,200 square feet or 50% of the floor area of the primary dwelling unit, whichever is less; provided, however, that if the size of the primary dwelling unit is less than 1,600 square feet, an attached ADU may have a total floor area of up to 800 square feet. b. Detached ADUs. The total floor area of a detached ADU shall not exceed the following: i. Studio or one bedroom: 850 square feet. ii. Two or more bedrooms: 1,200 square feet. c. Converted ADUs. The maximum size limitations set forth in this subsection do not apply to converted ADUs that do not increase the existing floor area of a structure. In addition, a converted ADU created within an existing accessory structure may include an expansion of not more than 150 square feet beyond the same physical dimensions as the existing attached or detached accessory structure to the extent necessary to accommodate ingress and egress. 3. Porches, Patios, and Garages. a. An attached or detached ADU, including converted ADUs, may include an attached covered patio and/or porch, which, if provided, shall be integrated into the design of the ADU and shall not exceed 80 square feet in size. b. An attached or detached ADU may include an attached one-car garage, which, if provided, shall not exceed 250 square feet in size inside dimension. The enclosed one-car garage shall maintain a minimum interior parking area of 10 feet by 20 feet. No storage cabinets or mechanical equipment, including, but not limited to, water heaters, utility sinks, or washers and dryers, shall encroach into the required parking area. c. In no event shall the total combined area of an ADU and attached porch, patio, and/or garage exceed 1,530 square feet. C. Setbacks. 1. Front Yard Setbacks. New attached and detached ADUs are subject to the same minimum front yard setback requirements applicable to other structures on the lot on which the ADU is located. Notwithstanding the foregoing, a portion of an ADU may be constructed within the required front setback area if, and only to the extent that, application of the minimum front setback requirement would not permit an ADU of up to 800 square feet to be constructed on the lot in compliance with all other applicable development standards. 2. Side and Rear Yard Setbacks. Minimum setbacks of no less than four feet from the side and rear lot lines are required for new attached and detached ADUs, new expansions to converted ADUs allowed pursuant to subsection B.2.c, and any new one-car garage, porch, and/or patio, allowed for a new ADU pursuant to subsection B.3. 3. Converted ADUs. No setbacks are required for converted ADUs, provided the side and rear yard setbacks of the existing converted structure are sufficient for fire and safety, as dictated by current applicable uniform building and fire codes. 4. Any new ADU garage that opens directly to any street or alley shall observe a setback of not less than 20 feet. When a new ADU garage abuts an alley and the access to the garage is perpendicular to the alley, the garage shall not be constructed closer than 20 feet to the centerline of the alley and shall maintain a minimum setback of five feet from the property line. D. Building Separation. 1. A minimum separation of six feet is required between a detached ADU and the primary dwelling unit. 2. A minimum separation of six feet is required between attached or detached ADU and all other structures not attached to the ADU, including garages, on the property. 3. Building separation requirements do not apply to converted ADUs that do not include an expansion of the floor area of the existing structure. E. Height. 1. Detached ADUs. a. Except as provided below, the height of a detached ADU on a lot with an existing or proposed single-family or multiple-family dwelling unit shall not be more than 16 feet in height. b. The height of a detached ADU located on a lot with an existing or proposed multiple-family, multistory dwelling unit shall not exceed 18 feet. c. The height of a detached ADU located on a lot with an existing or proposed single-family or multiple-family dwelling unit that is within one-half of one mile walking distance of a major transit stop or a high-quality transit corridor, as those terms are defined in Section 21155 of the Public Resources Code, shall not exceed 18 feet; provided, however, that up to an additional two feet in height is allowed if necessary to accommodate a roof pitch on the ADU that is aligned with the roof pitch of the primary dwelling unit. 2. Attached ADUs. a. The height of an attached ADU shall not exceed 25 feet or the height limitation that applies to the primary dwelling, whichever is lower. In no event shall an attached ADU exceed two stories. 3. Converted ADUs are not subject to a height limitation. 4. Measurement. The height of an ADU shall be as measured from ground level to the highest point on the roof. F. Design. 1. Except as otherwise provided in Government Code Section 66323, and except to the extent necessary to meet current fire and building codes, an attached or detached ADU shall match the architectural details of the primary unit as provided below: a. The type, pitch, color, material, and texture of the roof and eave details of an attached or detached ADU shall be the same as the primary unit. b. The color, material, and texture of all building walls, windows, and doors of an attached or detached ADU shall be the same as the primary unit. 2. In order to facilitate the development of ADUs in a manner that ensures reasonable consistency and compatibility of design, the Director is authorized to develop standard design plans and criteria for ADUs. Notwithstanding the foregoing, ADUs developed in conformance with plans pre-approved by the City, pursuant to Government Code Section 65852.27, shall be deemed to comply with this subsection. G. Off-Street Parking. 1. One off-street parking space must be provided for a new attached or detached ADU. The required parking space may be permitted in setback areas, or through tandem parking on a driveway, unless specific findings are made by the Director that parking in setback areas or tandem parking is not feasible based upon specific site or regional topographical or fire and life safety concerns. 2. Parking for a new attached or detached ADU is in addition to the required parking for the primary unit. However, when a garage, carport, covered parking structure, or uncovered parking space is demolished in conjunction with the construction of an ADU or converted to an ADU, those off-street parking spaces are not required to be replaced. 3. Off-street parking is not required in the following instances: a. The ADU is located within one-half mile walking distance of public transit, including transit stations and bus stations; b. The ADU is located within an architecturally and historically significant historic district; c. The ADU is part of the proposed or existing primary residence or accessory structure (i.e., a converted ADU); d. When on-street parking permits are required, but not offered to the occupant of the ADU; and/or e. When there is a car-share vehicle located within one block of the ADU. H. Exterior Access Required. An attached or converted ADU must have independent exterior access that is separate from the access to the proposed or existing primary dwelling. I. Passageway. No passageway shall be required in conjunction with the construction of an ADU. J. Laundry Facilities. An attached or detached ADU, including a converted ADU, shall have a laundry space located within the unit or within a garage accessible from the unit that is equipped with washer and dryer hook-ups. K. Water Heaters. An attached or detached ADU, including a converted ADU, shall have a separate hot water heater. The location of the water heater shall be incorporated into the design of the unit. No exterior water heater enclosures shall be permitted. Water heaters may be substituted with tankless water heaters provided all building codes are complied with. L. Mechanical Equipment, Metering Devices. All roof and ground mounted mechanical equipment and metering devices shall be completely screened from view from either on or off the property. All ground mounted equipment and above-ground utility meters, including, but not limited to, heating, cooling, or ventilating equipment, water meters, gas meters, and irrigation equipment, shall be shown on the site plan, and, to the extent possible, be placed outside of the required front setback area. If mechanical equipment or metering devices are to be located between a structure and the property line, an unobstructed path at least three feet wide shall be provided between the equipment and the property line. M. Refuse Storage Areas. All properties shall provide each unit with the appropriate number of containers for recyclables, organics, and non-recyclable solid waste ("trash containers") as required by the Garden Grove Sanitary District, and shall comply with the following: 1. Trash containers shall be stored within designated storage areas only and not within the garage parking area. 2. The placement of trash containers for pick-up, and the duration of time prior to and after trash collection of those trash containers, is subject to the Garden Grove Sanitary District requirements. 3. The area required for each container shall be a minimum of 38 inches by 38 inches. 4. The trash areas shall be paved and accessed by gates and a walkway for ease of taking trash containers to and from the street.
( 2919 § 8, 2021 ; 2966 , 8/12/2025 )
Ask a question about Garden Grove law
Corpus searches the Garden Grove sections it holds and shows the ones that match, with their citations. Free, no sign-in.
