§ 9.56.100 — Development Standards and Design Criteria
Code of Ordinances, City of Garden Grove, California (Code 2026-08-11) · Garden Grove Code of Ordinances § 9.56.100
Corpus is an independent public-information project, not the official City of Garden Grove website. Stable reference: corpuslaw.us/code/0bbfad36-31df-4c15-bff6-20f9e5fba71f
§ 9.56.100: Development Standards and Design Criteria.
A. Development Standards. A qualifying SB 9 two-unit residential development and any development on a lot created through an urban lot split shall be subject to the standards and criteria set forth in this section. In addition, except as modified or provided by this section or state law, an SB 9 two-unit residential development and any development on a lot created through an urban lot split shall conform to all objective development standards applicable to the lot as set forth in this title and/or in an applicable specific plan or planned unit development ordinance or resolution, along with all applicable objective standards and criteria contained in standard plans and specifications, policies, and/or standard conditions duly promulgated and/or adopted by the city, the Garden Grove Sanitary District, and the Orange County Fire Authority. B. Unit Size. 1. Minimum Size. Each new primary dwelling unit shall be at least the following minimum sizes based on the number of sleeping rooms provided: a. Studio/one bedroom: 500 square feet. b. More than one bedroom: 700 square feet. 2. Maximum Size. a. The total floor area of each new primary dwelling unit developed as part of an SB 9 two-unit residential development or on a lot created through an urban lot split shall not exceed 800 square feet. b. A primary dwelling that was legally established on the lot prior to the submittal of a complete application for an SB 9 two-unit development or an urban lot split and has a total floor area of 800 square feet shall be limited to its current lawful floor area and may not be expanded. c. A primary dwelling that was legally established prior to the submittal of a complete application for an urban lot split or an SB 9 two-unit residential development and that is smaller than 800 square feet may be expanded to 800 square feet. C. Unit Height; Stories. Each new primary dwelling unit shall be one story, constructed at ground level, and should not be more than 17 feet in height measured from ground level to the highest point on the roof. D. Setbacks. 1. New Primary Dwelling Units. The following minimum setbacks from the property lines shall be observed for each new primary dwelling unit and any garages and accessory structures that are attached to a new primary dwelling unit. Detached garages and accessory structures shall comply with the setbacks contained in subsection (D)(2). The required setbacks shall be maintained open and unobstructed from the ground to the sky, except for the permitted intrusions. a. Front setback: 20 feet. b. Interior side setback: five feet. c. Street side setback: 10 feet d. Rear setback: 15 feet. 2. Detached Garages and Accessory Structures. The following minimum setbacks from the property lines shall be observed for detached garages and accessory structures on a lot. a. Front setback: 20 feet. b. Interior side setback: five feet. c. Street side setback: 10 feet. d. Rear setback: five feet. 3. Any construction occurring on a lot that abuts a street that has not been fully improved shall observe all building setbacks from the ultimate right-of-way of the street. 4. Exceptions. The above minimum setback requirements do not apply or shall be modified in the following circumstances: a. No increased setback is required for an existing legally established structure or for a new primary dwelling unit that is constructed in the same dimensions as an existing legally established structure, provided that the new primary dwelling unit shall not be greater than 800 square feet. b. A required minimum setback may be reduced pursuant to subsection W of this section to the degree it would (i) physically preclude the development or maintenance of two dwelling units on a lot or (ii) physically preclude any new primary dwelling unit from being 800 square feet in floor area; but in no event may any structure be less than four feet from a side or rear property line. c. Permitted Intrusions. The following permitted intrusion may project into any required setback a maximum of two feet: cornices, eaves, belt courses, sills, buttresses, planter boxes, masonry planters, guard railings, chimneys, and architectural projections with no floor area, including, but not limited to, windows and pilasters. E. Building Separation. Except as otherwise allowed by state law, a minimum building separation of six feet shall be maintained between all detached structures on a lot, including all residential units, garages, and accessory structures. F. Lot Coverage. The maximum lot coverage shall not exceed 50%. The lot coverage shall include all buildings and structures (primary and accessory), covered porches and patios, and covered parking areas. G. Maximum Front Setback Coverage. No more than 50% of the front setback area may contain hardscape, excluding the allowed standard driveway in the front yard. H. Open Space. Each new primary dwelling unit shall provide, at a minimum, a continuous private recreation area of 225 square feet with minimum interior dimensions of 10 feet. The private recreation area shall be open and unobstructed from the ground to the sky. The private recreation area may be located within the interior side, street side, or rear setback areas. I. Landscaping. All setback areas, and all areas not designated for walkways, parking, drive aisles, and private recreation areas, shall be fully landscaped and irrigated. Each development shall comply with the landscaping and irrigation requirements contained in Chapter 9.08 of Title 9. J. Perimeter Block Walls. Each development shall provide a masonry perimeter wall with a minimum height of six feet, as measured from the highest point of the finished grade next to the wall, and shall comply with the following stipulations: 1. All perimeter walls shall comply with the requirements as contained in Section 9.08.040.110, Wall, Fences and Hedges. 2. New walls shall not exceed a height of seven feet as measured from the finished point of grade next to the wall. At no time shall the overall height of the wall, as measured from adjacent neighbor's finished grade, exceed eight feet in height. 3. Walls located within the front yard areas, or adjacent to driveways shall not exceed 36 inches in height. 4. Perimeter walls located along any side street shall maintain a minimum setback of three feet from the property line for landscaping purposes. 5. All walls shall be designed to ensure proper vision clearance for cars entering or leaving the driveway and parking areas. No wall or fence shall cause an exceedance of the applicable site distance standards set forth in City of Garden Grove Traffic Engineering Policy TE 13 or in any revised or updated standard or policy promulgated by the city. 6. The property owner shall work with the adjoining property owners in designing and constructing the perimeter block walls to avoid the use of double walls. If the property owner cannot obtain approval from the adjoining property owners, the property owner shall construct the new wall with a decorative cap to be placed between the new and the existing wall. 7. Street facing perimeter block walls shall be decorative and utilize stucco finish, slump stone or split-face block and shall include trailing vines and other landscaping to deter graffiti. K. Off-Street Parking. 1. Required Parking. One off-street parking space must be provided for each new primary dwelling unit unless one of the following applies: a. The lot is located within one-half mile walking distance of either: (i) a high-quality transit corridor as defined in subdivision (b) of Section 21155 of the California Public Resources Code; or (ii) a major transit stop as defined in Section 21064.3 of the California Public Resources Code. b. The lot is located within one block of a car-share vehicle location. 2. Off-street parking spaces for an existing primary dwelling shall continue to be provided in accordance with the standards for the underlying zone. 3. Required parking for new primary dwelling units may be provided within an enclosed garage or as open spaces on the lot, but not as tandem parking. Open spaces may be located within the side or rear setbacks, and in the front setback for driveways that are not shared by more than one housing unit. 4. All required parking spaces provided shall be a minimum of nine feet wide and 19 feet in depth and shall comply with the size requirements for full size stalls set forth in Standard B-311 of the Standard Plans and Specifications adopted by the City. Parking spaces adjacent and parallel to walls shall be a minimum of 11 feet wide. 5. Any proposed enclosed garage shall meet the following standards: a. Each enclosed garage shall maintain the following minimum interior parking clearance based on the number of cars it is designed to hold. No storage cabinets or mechanical equipment, including, but not limited to water heaters, utility sinks, or washers and dryers, shall encroach into the required parking area. Number of Cars | Minimum Interior Parking Area 1 | 10 feet x 20 feet 2 | 20 feet x 20 feet b. The garage shall be equipped with an automatic roll-up garage door opener. c. Each garage shall maintain the ability to park the required number of vehicles at all times. L. Unit Design Standards. 1. If there is an existing primary dwelling that was legally established on the lot prior to the filing of a complete application for a two-unit development or an urban lot split, any new additional primary dwelling unit must match the existing primary dwelling unit in exterior materials, color, and dominant roof pitch. The dominant roof slope is the slope shared by the largest portion of the roof. 2. If two new primary dwelling units are developed on the lot, the dwellings must match each other in exterior materials, color, and dominant roof pitch. The dominant roof slope is the slope shared by the largest portion of the roof. 3. All exterior lighting must be limited to down-lights. 4. Each new primary dwelling unit shall have a main entry that is clearly defined, and to the extent possible, be oriented directly toward the street(s) in order to provide consistency with the neighborhood. The main entry shall be covered, with a minimum depth of three feet. Each covered entry shall be in proportion with the building and shall incorporate architectural features that are used in the overall building design. All doors shall have standard door locks and dead bolts. M. Storage Facilities. Each new primary dwelling unit shall provide a minimum 144 cubic feet of private secure storage space. Normal closets and cupboard space located within the unit shall not count toward meeting the requirement. N. Laundry Facilities. Each new primary dwelling unit shall have a laundry space located within the unit or within a garage accessible from the unit that is equipped with washer and dryer hook-ups. If the laundry facilities are located within an enclosed garage, the laundry equipment shall not encroach into the interior garage parking area. O. Water Heaters. Each new primary dwelling unit shall have a separate hot water. The location of the water heater shall be incorporated into the design of each unit. No exterior water heater enclosures shall be permitted. Water heaters may be substituted with tankless water heaters provided all building codes are complied with. P. Mechanical Equipment, Metering Devices. All roof and ground mounted mechanical equipment and metering devices shall be completely screened from view from either on or off the property. All ground mounted equipment and above-ground utility meters, including, but not limited to, heating, cooling, or ventilating equipment, water meters, gas meters, and irrigation equipment, shall be shown on the site plan, and, to the extent possible, be placed outside of the required front setback area. If mechanical equipment or metering devices are to be located between a structure and the property line, an unobstructed path at least three feet wide shall be provided between the equipment and the property line. Q. Access and Circulation. 1. Each development shall be designed to provide adequate on-site vehicular access, circulation, back-up, and turn-around areas that comply with all the applicable city standards. 2. Where the street frontage of a lot (or the combined street frontage of the two lots created through an urban lot split) is less than 81 feet, all units on the lot (or all units on both lots created through an urban lot split) shall share the same drive approach and driveway. 3. Driveways shall maintain a minimum width of 20 feet, unless a wider width is required for emergency access. 4. Adequate access to each residential unit on the lot for fire and emergency medical service personnel and vehicles must be provided. The Orange County Fire Authority must confirm that all applicable fire and emergency access requirements are met before the city will approve an application. R. Refuse Storage Areas. All developments shall provide each unit with the appropriate number of containers for recyclables, organics, and non-recyclable solid waste ("trash containers") as required by the Garden Grove Sanitary District, and shall comply with the following: 1. Trash containers shall be stored within designated storage areas only and not within the garage parking area. 2. The placement of trash containers for pick-up, and the duration of time prior to and after trash collection of those trash containers, is subject to the Garden Grove Sanitary District requirements. 3. The area required for each container shall be a minimum of 38 inches by 38 inches. 4. The trash areas shall be paved and accessed by gates and a walkway for ease of taking trash containers to and from the street. S. Utilities. 1. Each primary dwelling unit on a lot must have its own direct utility connection to the utility/public service provider. 2. All necessary and/or required easements for the provision of electricity, gas, water, sewer, and other utility or public service to the lot and each primary dwelling unit must be obtained by the property owner/applicant. The city may condition approval of an application under this section upon the applicant providing evidence that such easements have been agreed to and/or recorded. 3. Submitted plans shall show the location and dimension of all proposed above-ground and underground utility and public service facilities serving the lot and each dwelling unit and the location and dimensions of all related easements. T. Building and Safety. All structures built on the lot must comply with all current local building standards. U. Drainage and Stormwater Management. Each lot shall drain to the street or to an approved storm drain facility. The design of parkway culverts and storm drain lateral pipe connections to city-maintained storm drains within the City right-of-way shall comply with applicable City standards. SB 9 two-unit residential developments and the development of lots created through an urban lot split are subject to Chapter 6.40 of this Code ("Stormwater Quality") and must comply with all applicable related rules, requirements, and standards, including, but not limited to, the preparation and implementation of a water quality management plan that meets applicable requirements. V. Address Identification. Each residential unit shall have a separate address and shall be provided with approved address identification that is visible from the street fronting the lot in accordance with Section R319 of the California Residential Code. Where the unit address on the building cannot be viewed from the street fronting the lot, a monument, pole, or other means consistent with City standards shall be used to identify the unit. Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. W. Exceptions to Objective Standards. 1. Any objective zoning, subdivision, or design standard that would have the effect of physically precluding the construction of up to two primary residential units on a lot or that would physically preclude each new unit from being 800 square feet in floor area shall be modified or waived to the extent necessary to allow the development of two primary residential units on a lot pursuant to this chapter that are each 800 square feet in floor area. The city prioritizes some objective development standards over others, as provided in subsection (W)(2) below. In applying the exceptions required by this subsection, a proposed project shall be designed such that a development standard given a lower priority is modified or waived before a development standard given a higher priority. If a proposed project can be designed such that each lot can accommodate two 800 square foot primary dwelling units by modifying or waiving a development standard with a lower priority, then an application that proposes a design requiring the modification or waiver of a development standard with a higher priority will be denied. 2. Priority of Development Standards. The City prioritizes the following development standards in the following descending order of priority, with the first development standard listed having the highest priority: a. Height; Stories. b. Front setback. c. Maximum front setback hardscape coverage (50%). d. Open space (225 square feet). e. Minimum unit size. f. Side or rear setback (a minimum of four feet must be maintained). g. Lot coverage (50%). h. Building separation (minimum separation required by Building Code must be maintained). 3. This subsection shall not be interpreted to permit the construction of new garages or accessory structures, or the maintenance of existing accessory structures not providing required parking, where the development or maintenance of two 800 square foot dwelling units on the lot would not be physically precluded in the absence of such proposed or existing structures. 4. Building standards, standards required by federal, state or local law or for sanitation or safety reasons, the off-site parking requirements in subsection K of this section, and the lot size, access, and frontage requirements set forth in Section 9.56.110 will not be waived or modified unless otherwise required by state law. 5. As part of its application, the applicant shall provide a written explanation that: (a) specifically describes every development standard the applicant seeks to modify and waive, and to what extent; (b) demonstrates why waiver or modification of each development standard is needed to prevent physically precluding the construction of up to two primary residential units on the lot and/or each new unit from being at least 800 square feet in floor area; and (c) demonstrates that the requested modifications and/or waivers are consistent with the priority set forth in this subsection.
( 2929 § 3, 2022 )
Ask a question about Garden Grove law
Corpus searches the Garden Grove sections it holds and shows the ones that match, with their citations. Free, no sign-in.
