§ 30.11.050 — Residential district additional R-3050, R-2250, R-1650 and R-1250 development standards
Code of Ordinances, City of Glendale, California (Code 2026-05-19) · Glendale Code of Ordinances § 30.11.050
Corpus is an independent public-information project, not the official City of Glendale website. Stable reference: corpuslaw.us/code/2e9caa65-0664-4865-b5c6-6988376b6e1d
§ 30.11.050: Residential district additional R-3050, R-2250, R-1650 and R-1250 development standards.
The following standards shall apply in the R-3050, R-2250, R-1650, and R-1250 zones. A. Dwelling Unit Size. The gross floor area of any dwelling unit shall not be less than provided herein. For the purpose of this section, dens, studies or other similar rooms which may be used as bedrooms shall be considered as bedrooms. Living rooms, dining rooms, kitchens, or bathrooms shall not be considered as bedrooms except that separate dining rooms in efficiency units or rooms that could be converted into additional bedrooms shall be considered as bedrooms. 1. Efficiency and one-bedroom units: 600 square feet. 2. Two-bedroom units: 800 square feet. 3. Three- or more bedroom units: 1,000 square feet. B. Private Outdoor Space. A minimum private outdoor space of 50 square feet shall be provided for each dwelling unit. Such private outdoor space shall be designed as a patio, deck, or balcony and shall have a minimum length or width of five feet and shall be directly accessible and an integral part of the dwelling unit which it serves. C. Common Open Space Amenity Areas. All multi-family residential developments shall include one or more common open space amenity (COSA) areas, except for projects consisting of seven units or less that elect to provide larger private outdoor space areas in accordance with subsection C.5 below. The required amount of COSA areas shall depend on the lot width of the project site and the option chosen for the interior setbacks described in Table 30.11-D and as depicted in Figures 30.11.050.A through D below. 1. Area calculation. All COSA areas shall comply with the minimum COSA area and dimension standards in Table 30.11-D. No street front or street side setback area shall be used for the COSA area calculation. 2. Location. The COSA area shall be located on the ground floor in one continuous space, open toward at least one setback area and accessible by all residents. For lots greater than 90 feet in width, the required COSA area may be split into two continuous areas with a minimum of fifty percent of the COSA area on the ground floor. 3. Open to the sky. A minimum of 90% of the COSA areas shall be open to the sky. No building projections, including roof eaves, cantilevered overhangs or balconies, shall project more than 24 inches into this space. 4. Amenities. Landscaping and seating shall be permanently integrated into all required COSA areas. See GMC Chapter 30.17 for additional requirements. 5. Street access to interior courtyard COSA area. A minimum eight-foot-wide area consisting of a walkway and a minimum of 25% landscaping shall be provided as access to a ground floor COSA area from the front or side street property line. 6. Buffer. The following standards apply when a ground floor residential unit abuts a COSA area: a. Buffer for ground floor units. All ground floor units shall be separated from the COSA area by either a minimum five-foot-wide (interior measurement) private outdoor space or a minimum two-foot-wide (interior measurement) landscape planter planted with vertically oriented, taller shrubs. Delineation between ground floor private outdoor space from COSA areas shall be provided by a wall or fence not exceeding 48 inches in height, vertically oriented landscaping, or a combination thereof. b. Openings. Where doors or windows of a ground floor unit directly face a COSA area, a minimum five-foot wide (interior measurement) landscape or paved buffer area shall be provided between the COSA and the unit openings. 7. Multi-family residential developments with seven units or less. A minimum of 200 square feet of private outdoor space per unit may be provided in lieu of the required COSA area, subject to the following: a. The minimum length and width of such private outdoor space shall be increased to eight feet. b. For residential units with living space on the ground floor, a minimum 100 square feet of private outdoor space per unit shall be located on the ground floor. c. Such private outdoor area shall be located outside of any street front and street side setback area. Table 30.11-DCommon Open Spaces Amenity Area Standards Option 1 | Option 2 Interior Setbacks | 5 feet minimum, 8 feet average | 6 feet minimum Common Open Space Amenity (COSA) Area Minimum Size | 10% of site area | 15% of site area Min. COSA Dimension | 15 feet for lot width 90 feet or less and 25 feet for lot width greater than 90 feet Figure 30.11.050-AInterior COSA Areas for Lot Widths 90 Feet or Less [image] Figure 30.11.050-BFront Corner COSA Areas for Lot Widths 90 Feet or Less [image] Figure 30.11.050-C.Interior COSA Areas for Lot Widths Greater Than 90 Feet [image] Figure 30.11.050-DFront Corner COSA Areas for Lot Widths Greater Than 90 Feet [image] Note: these figures are for illustrative purposes only and do not represent all possible COSA design alternatives. D. Distance Between Dwellings. Exterior walls of separate buildings containing dwelling units on the same lot shall be separated by a minimum distance of five feet. Where the windows or window/doors of any one dwelling unit face the windows or window/doors of any other dwelling unit, the exterior walls shall be separated by a distance of 12 or more feet, except where the angle between the wall of the separate dwelling units is 90 degrees or more. Walls parallel to each other shall be considered to be at a zero degree angle. E. Rooftop Equipment. For regulations concerning rooftop equipment, see Section 30.30.020 of this title. F. Fences and Walls. For regulations concerning fences and walls, see Sections 30.17.040 and 30.30.010. G. Trash Collection Areas. For regulations concerning trash collection areas, see Section 30.30.030. Waste receptacles and recycling containers shall be prohibited in all required setback areas and COSA areas. Such containers shall be located within a designated service area within the building or at the rear or side of the building outside of any required setback. H. Access to Dwelling Units. An elevator shall be provided to serve all stories in a building containing more than three dwelling units where the floor area of any dwelling unit is located only on the third story and other dwelling units are located on the first and second stories. I. Laundry Facilities. Laundry facilities shall be provided to serve all dwelling units on a lot. Such laundry facilities, constituting washer and dryer appliances connected to utilities, shall be provided in the individual dwelling units where there are three or less dwelling units on a lot. Where there are more than three dwelling units on a lot, laundry facilities shall either be provided in the individual dwelling units or in a common laundry room. A common laundry room shall be in an accessible location and shall have at least one washer and one dryer for each 10 dwelling units, maintained in operable condition and accessible to all tenants daily between the hours of 7:00 a.m. and 10:00 p.m. J. Storage Space - Private. A minimum of 90 cubic feet of private storage space shall be provided for each dwelling unit outside such unit unless a private attached garage serving only the dwelling unit is provided. Such private storage space shall have a minimum horizontal surface area of 24 square feet and shall be fully enclosed and lockable. K. Additional Standards for Floor Area Ratio Minimums. 1. Any development of three to seven multiple residential dwelling units shall not have a floor area ratio standard that is less than 1.0. 2. Any development of eight to 10 multiple residential dwelling units shall not have a floor area ratio standard that is less than 1.25. 3. To be eligible for the provisions in subsections K.1 and K.2 above, a multi-family housing development project shall meet all of the following conditions: a. The project consists of at least three, but not more than 10, units. b. The project is located in a multi-family residential zone, commercial zone, or a mixed-use zone, and is not located in either of the following: i. Within a single-family zone. ii. Within a historic district or property that is included on the State Historic Resources Inventory, as defined in Public Resources Code Section 5020.1, or within a site that is or contains buildings, sites, objects, structures, neighborhoods, cultural landscapes, and archaeological sites, that are designated or listed as a city or county landmark or historic property or district pursuant to a city or county ordinance. 4. This subsection shall not be construed to prohibit the city from imposing any zoning or design standards, including, but not limited to, building height and setbacks, on a housing development project that meets the requirements of this subsection, other than zoning or design standards that establish floor area ratios or lot size requirements that expressly conflict with the standards contained in this subsection. 5. The city may not impose a lot coverage requirement that would physically preclude a housing development project that meets the requirements of this subsection from achieving the floor area ratio allowed herein. L. Height Standards for Sloped Lots. For multi-family residential projects located on lots with an average current slope greater than 10%, the building form and massing shall be designed to follow the natural topography of the site. For such projects, building height shall be measured by both "building envelope height," defined below, and height, as defined in Chapter 30.70, to ensure compatibility with sloping terrain while limiting excessive building size and mass. "Building envelope height" shall be measured from the lowest point of the building, structure, or building wall exposed above the ground surface to the highest point of the roof, parapet wall or uppermost building element located directly above and parallel to the existing grade. For projects on lots with an average current slope greater than 10%, the maximum permitted "building envelope height" shall be the height limit specified in Table 30.11.B. The maximum permitted height shall be 50 feet for projects with flat roofs, and 55 feet for any roofed area having a minimum pitch of three feet in 12 feet, as illustrated in Figure 30.11.050-E. Figure 30.11.050-EHeight Standards for Sloped Lots [image]
( Ord. 5399 Attach. A, 2004 ; Ord. 5997 § 4, 2022 ; Ord. 6034 , 12/3/2024 ; Ord. 6052 , 5/19/2026 )
Ask a question about Glendale law
Corpus searches the Glendale sections it holds and shows the ones that match, with their citations. Free, no sign-in.
