For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 30.30.050 — Solar energy equipment

Code of Ordinances, City of Glendale, California (Code 2026-05-19) · Glendale Code of Ordinances § 30.30.050

Corpus is an independent public-information project, not the official City of Glendale website. Stable reference: corpuslaw.us/code/181dd12e-3ad1-4569-b6fe-b8e62d527b0d

§ 30.30.050: Solar energy equipment.

Notwithstanding any other provisions of this title, any overlay zone, or any specific plan, the following development standards shall be modified as listed below when applicable to solar energy equipment, in order to facilitate the installation of solar energy equipment, as defined in this title. Solar energy equipment shall not be subject to the development plan review process of Section 30.15.040(F) in this title. A. Street Front Setback. Solar energy equipment shall not be permitted in the street front setback area except as follows: If a building is located within the street front setback area by variance, administrative exception, or nonconforming entitlement, solar energy equipment may extend over those portions of the building that are located within the street front setback area and may extend a maximum of one foot beyond the perimeter of those portions of the building that are located within the street front setback area. For purposes of this section, the perimeter of the building shall be defined as the outer boundary of any roofed area of the building and shall also include any uncovered or partially covered portions of such building. B. Street Side Setback. Solar energy equipment shall not be permitted in the street side setback area except as follows: If a building is located within the street side setback area by variance, administrative exception, or nonconforming entitlement, solar energy equipment may extend over those portions of the building that are located within the street side setback area and may extend over one foot beyond the perimeter of those portions of the building that are located within the street side setback area. For purposes of this section, the perimeter of the building shall be defined as the outer boundary of any roofed area of the building and shall also include any uncovered or partially covered portions of such building. C. Interior Setback. The required interior setback shall be reduced by 30% or as follows: If a building is located within the interior setback area by variance, administrative exception, or nonconforming entitlement, solar energy equipment may extend over those portions of the building that are located within the interior setback area and may extend a maximum of one foot beyond the perimeter of those portions of the building that are located within the interior setback area. For purposes of this section, the perimeter of the building shall be defined as the outer boundary of any roofed area of the building and shall also include any uncovered or partially covered portions of the building. D. Height. 1. Solar energy equipment that is detached shall not exceed a height of 15 feet. Height shall be measured from the lowest point of the structure supporting the solar panels that is exposed above the ground surface to the highest point of such structure, including the solar panels. 2. Solar energy equipment that is attached to a building shall not exceed a height of 15 feet in addition to the allowable height of the building. Solar energy equipment that is attached to a building shall not exceed a height of 15 feet in addition to the height of the building when the building height is approved by variance or administrative exception, or when the building height has a nonconforming status. Height shall be measured from the lowest point of the building exposed above the ground surface to the highest point of the structure supporting the solar panels, including the solar panels. 3. Solar energy equipment that is attached to a deck or pool shall not exceed a height of 15 feet in addition to the allowable height of the deck or pool. Solar energy equipment that is attached to a deck or pool shall not exceed a height of 15 feet in addition to the height of the deck or pool when the deck or pool height is approved by variance or administrative exception, or when the deck or pool height has a nonconforming status. Height shall be measured from the lowest point of the deck or pool exposed above the ground surface to the highest point of the structure supporting the solar panels, including the solar panels. E. Lot Coverage. Where lot coverage standards are applicable, an increase of 30% to the allowable lot coverage shall be permitted. The allowable increase may be occupied solely by solar energy equipment. F. Landscaping. Where the percentage of total lot area to be permanently landscaped open space standards are applicable, a reduction of 30% to the minimum percentage of total lot area to be permanently landscaped open space shall be permitted. The allowable reduction may be occupied solely by solar energy equipment.

( Ord. 5712 § 14, 2010 )

Ask a question about Glendale law

Corpus searches the Glendale sections it holds and shows the ones that match, with their citations. Free, no sign-in.