§ 10-28.4.1.020 — MAJOR SITE PLAN REQUIRED
Hayward Municipal Code (Supp. No. 28, Update 2: codified through Ordinance No. 26-08, adopted August 18, 2026) · Hayward Municipal Code § 10-28.4.1.020
Corpus is an independent public-information project, not the official City of Hayward website. Stable reference: corpuslaw.us/code/52d614e2-ae65-42c2-820f-d14ccad4220f
10-28.4.1.020 - MAJOR SITE PLAN REQUIRED
A. Sites subject to this Division must obtain Major Site Plan Review in compliance with Section 10-1.3000 (Site Plan Review) of the Hayward Code and the requirements of this Division. B. Submittal Requirements. In addition to the requirements of Section 10-1.3000 (Site Plan Review) of the Hayward Code, applicants must: 1. Layout a block and thoroughfare network in compliance with the standards in Subsections C and D; 2. Provide a mix of building types by using at least two types allowed by the zone, in compliance with Division 3.3 (Specific to Building Type); 3. Allocate and design civic spaces and civic buildings in compliance with the standards in Division 4.2 (Specific to Civic Spaces); 4. Provide appropriate physical transitions to the intended physical scale and character of the surrounding area; 5. Design the site to suit specific environmental, site layout, and design constraints unique to the site or its location; 6. Identify the proposed blocks and thoroughfares, Downtown Zones, civic space types, and building types on a project regulating plan in compliance with Subsection E; and 7. Identify the proposed physical character of the site on a project illustrative plan by showing the proposed buildings and roofs on each block in plan view. [image omitted; see the official code] Figure 4.1.020.1 Walkable Urban Site Transformation Process C. Thoroughfares. Thoroughfares, public or private, define the public streets that refine large sites into walkable urban environments that also provide multiple routes for vehicular circulation. 1. Design. a. Thoroughfares must comply with City standards. b. Thoroughfares that pass through multiple zones must transition to align with the character of the zone. For example, while a thoroughfare within a Downtown Main Street (DT-MS) Zone with retail shops may have wide sidewalks with trees in tree grates, it may transition to a narrower sidewalk with a planting strip within a less urban zone with lower intensity residential building types (e.g., Neighborhood Edge (NE) Zone). c. The thoroughfare network must be mapped on the project regulating plan and must indicate the layout of thoroughfares and the block network in compliance with standards in this Subsection, Subsection D, and Table A (Block Size). d. The location of new streets may be adjusted from the location identified in Figure 2.1.020.1 (Regulating Plan) subject to City review and approval. 2.1.020.1 (Regulating Plan) shall be revised to reflect the final street locations and alignments as approved by the City. 2. External Connectivity. a. Thoroughfares must be arranged to connect to existing or proposed thoroughfares into adjoining lands whether the adjoining lands are undeveloped and intended for future development, or if the adjoining lands are developed and include opportunities for such connections. b. Thoroughfare rights-of-way must be extended to or along adjoining property boundaries to provide a roadway connection or thoroughfare stub for development in compliance with the standards in Subsection D (Block Size). c. The project regulating plan must identify all stubs for thoroughfares and include a notation that all stubs must connect with future thoroughfares on adjoining undeveloped property. d. Dead-end streets and cul-de-sacs are not allowed. D. Block Size. 1. Individual block faces and the total block perimeter must comply with the standards established in Table A (Block Size). 2. If a block contains multiple zones, the most intense zone must be used to establish the requirements for block size. 3. Minimum block width is two times the minimum lot depth for the zone. Table 4.1.020.A Block Size Zone | New Block Face Length | Perimeter Length NE | 400 ft. max. | 1,400 ft. max. UN | 450 ft. max. | 1,400 ft. max. NG | 450 ft. max. | 1,600 ft. max. DT-MS | 500 ft. max. | 2,400 ft. max. UC | 500 ft. max. | 2,400 ft. max. [image omitted; see the official code] E. Project Regulating Plan. 1. The project regulating plan must include the following information: a. Site boundaries; b. Existing and proposed blocks; c. Existing and proposed thoroughfares, including alleys; d. Existing and proposed civic space type(s) and open space(s); e. Existing and proposed zone(s). 2. If rezoning is proposed, only zones established in Division 2.2 (Downtown Zones) may be used. 3. The project regulating plan is subject to the review and approval of the Planning Commission. If a project regulating plan is approved with Major Site Plan Review, the information on the diagram must be transferred to the Hayward Zoning Map.
Ask a question about Hayward law
Corpus searches the Hayward sections it holds and shows the ones that match, with their citations. Free, no sign-in.
