§ 10-3.375 — STANDARDS OF DEVELOPMENT
Hayward Municipal Code (Supp. No. 28, Update 2: codified through Ordinance No. 26-08, adopted August 18, 2026) · Hayward Municipal Code § 10-3.375
Corpus is an independent public-information project, not the official City of Hayward website. Stable reference: corpuslaw.us/code/ac8c8055-82e0-4410-96ee-12dda76cc398
SEC. 10-3.375 - STANDARDS OF DEVELOPMENT.
Except as herein provided, standards in the Municipal Code and the General Plan shall apply, and the standards for improvements within the common area shall be those expressed as conditions to approval of the tentative map and the Site Plan Review approval documents. a. Site Plan Review shall be required and an application submitted therefore with every application for a tentative map for conversion of a rental complex to ownership housing. b. Parking shall be provided in accordance with the City of Hayward Off-Street Parking Regulations in effect at the time the application to convert to ownership housing is deemed complete. For conversions involving three-and four-unit developments, exceptions to the Off-Street Parking Regulations may be granted by the Planning Director if it is determined that it would not be physically feasible to meet the Off-Street Parking Regulations without eliminating a dwelling unit, due to site constraints such as lot size or shape, steep topography, significant trees or structures. However, at least one designated parking stall per dwelling unit shall be required. c. Prior to sale of units, the applicant shall be responsible for the physical conditions within individual units and common areas. Verification of the integrity of the building(s) shall be included in reports which indicate that minimum standards that are outlined below will be adequately addressed and remedied prior to sale of units. The reports required in this section must be provided to the City Planning Director prior to approval of the final map. d. Building Condition: 1. The applicant shall submit a report by a licensed civil or structural engineer addressing structural issues with the building(s). This report shall include recommendation for correction of any structural deficiencies, which shall be remedied prior to close of escrow of each unit. Such issues shall include, but not be limited to: (aa) Soft story conditions, as defined in Chapter A4 of the latest edition of the International Existing Building Code. (bb) Lateral movement at walls with garage door openings. (cc) Structural integrity of exterior balconies and their supporting members. (dd) Seismic sufficiency of conditions at sub-floor areas including: i. condition of foundation. ii. attachment of mudsill to foundation. iii. attachment of floor joists to sub-floor area cripple walls iv. plywood shear walls at corners of sub-floor area. v. Sub-floor ventilation. 2. The applicant shall provide a report by a licensed pest control company. Any work listed on the report shall be completed and cleared by the pest control company prior to occupancy. 3. Fire/Life Safety: (aa) fire alarm system shall be required per the current California Fire Code and NFPA 72. The Fire Alarm system shall be zoned and have an on-site annunciator panel that will identify the specific fire alarm device that is activated and its specific location. The fire alarm system will be required to have a local alarm and also be supervised by an approved and listed central station monitoring company. All dwelling units shall be required to have hard-wired single station [hard wired with battery (back-up) smoke detectors]. These single station smoke detectors shall not be interconnected with the fire alarm system. (bb) Doors from individual dwelling units opening into an interior corridor shall be part of a listed assembly with a minimum 20-minute fire rating. 4. Electrical: (aa) Each unit greater than 900 square feet shall have an electrical service rated at 100 amps minimum. Each unit less than 900 square feet shall have an electrical service rated at 60 amps minimum. (bb) Electrical circuits and outlets at kitchen and bathroom shall meet current electrical code minimums. (cc) All bathroom outlets and all kitchen countertop outlets within 6 feet of a sink shall be GFCI protected. (dd) Any new bedroom circuits shall be ARC fault protected. (ee) Each kitchen shall have two separate circuits for small appliances. (ff) All circuits, panels and metallic water lines shall be effectively grounded: gas lines shall be bonded to the grounding electrode system. 5. Energy: (aa) All gas furnaces/heating units shall have an ENERGY STAR rating from the Federal Management Program. At the time of conversion, all electric furnaces/heating units shall meet energy efficiency standards as published by the City of Hayward for electric furnaces in conjunction with the adoption of the electrical code. (bb) All windows within each unit shall be double-paned. (cc) All electrical outlets on exterior walls shall have foam gaskets. (dd) Install programmable thermostats for all heaters and furnaces. (ee) All exterior doors shall be tight fitting and have weather stripping. (ff) All plumbing fixtures, including toilets, shall be of water conserving design per the latest California Plumbing Code requirements. 6. Separation of Units and Sound Control: (aa) Draft stops shall be installed in attics in line with walls separating units from each other and from corridors, laundry rooms and other jointly used spaces. (bb) Sound transmission control shall be in place: provide results of on-site testing showing how State standards will be met or provide gypsum board sheathing mounted on channel on one side of tenant separation walls. (cc) Area separation walls that were part of the original construction shall be checked for integrity. 7. Accessibility. Accessibility for persons with disabilities shall be provided in all public areas to the maximum extent feasible. Some of the items to be addressed are: (aa) Main entry to each building shall be accessible. (bb) An accessible route of travel connecting all accessible elements and common use spaces of a building shall be provided. (cc) If visitor parking is provided accessible parking per California Title 24 shall be provided. (dd) Where structural or site conditions preclude installation of an accessibility measure, the applicant may apply to the Building Official for a hardship exemption for the specific element under consideration. e. Laundry facilities shall be provided within each converted rental complex, either communally or within individual dwelling units. f. Rental projects that do not conform to the density specified by the Zoning Ordinance shall not be converted to a Common Interest Development unless the conversion would result in eliminating the non-conforming status of the project related to density.
Ask a question about Hayward law
Corpus searches the Hayward sections it holds and shows the ones that match, with their citations. Free, no sign-in.
