§ 2-6.45 — REFUELING, DEFUELING AND FUEL STORAGE
Hayward Municipal Code (Supp. No. 28, Update 2: codified through Ordinance No. 26-08, adopted August 18, 2026) · Hayward Municipal Code § 2-6.45
Corpus is an independent public-information project, not the official City of Hayward website. Stable reference: corpuslaw.us/code/d24ebe23-9917-4d0a-b0af-dda134a12a1d
SEC. 2-6.45 - REFUELING, DEFUELING AND FUEL STORAGE.
Refueling, defueling and fuel storage on the Airport shall conform to the current applicable provision of 14 CFR; applicable Regulatory Measures; all appropriate NFPA guidelines; FAA Advisory Circular 150-5230-4 (as amended); applicable provisions of the Airport's SWMP; applicable provisions of the Regulatory Measures established by the Environmental Protection Agency and the California Department of the Environment relating to these activities. This Section shall apply to ALL FBO's and Self-Fueling Permittees. Fuels shall only be dispensed on the Airport by those entities having an Agreement with the Airport granting such permission. a. Training. No person shall fuel or defuel an Aircraft until that person is properly trained. Training records documenting the training provided to (and qualifications of) each person shall be maintained. (1) Records shall indicate initial training and all recurrent training provided. (2) Recurrent training shall be provided on a regularly scheduled basis, but not less than every year. (3) All records shall be subject to review of and/or inspection by the Airport Manager or Fire Marshal. b. Refueling, Defueling and Fuel Storage Operations. A properly trained operator shall be present (and responsive) at all times while Refueling Vehicles transfer fuel into or out of any fuel storage facility and while refueling any Aircraft. (1) The operator shall remain within the immediate vicinity, in close proximity to, and in direct view of all operating controls and Equipment. (2) The operator shall not leave the discharge end of any hose or hoses unattended at any time while the transfer of fuel is in progress. (3) The operator shall not block open, disengage, and/or deactivate the deadman switch while fueling and/or transferring fuel. c. Aircraft shall not be refueled or defueled in an area where Aircraft engines are operating, Aircraft (or engines) are being warmed by application of heat, or while the Aircraft is located in a congested space. d. Aircraft shall not be refueled or defueled inside any hangar or while positioned so that Aircraft fuel system vents or fuel tank openings are closer than 25' to any terminal building, hangar, service building or structure (NFPA 407, Section 5.10.2) e. Pouring or gravity transfer of fuel from containers larger than five (5) gallons is prohibited. (1) All containers shall be approved by the Fire Marshal and shall be in approved type pursuant to UFC Sec. 79.104 and legibly marked. Capacity shall conform to UFC Table No. 79.104. f. All fuel handled on the Airport shall be treated with due caution and circumspection with regard to the rights and safety of others so as not to endanger, or likely to endanger, persons or property. g. Persons engaged in the fueling, defueling and oil servicing of Aircraft (or Vehicles), the filling of Refueling Vehicles or dispensing Equipment, or the dumping or pumping or loading of aviation Fuels (or oils) into or from Fuel (or oil) storage facilities shall exercise care and extreme caution to prevent overflow of Fuel (or oils) and/or spills. h. Refueling Vehicles shall be positioned so that the Vehicle can be directly driven away from the loading or fueling position in the event of fire or spill. i. Not more than one (1) Refueling Vehicle shall be positioned to refuel each wing of an Aircraft and not more than two (2) Refueling Vehicles shall be positioned to service the same Aircraft. j. Aircraft (or Vehicles) shall not be fueled or defueled while an engine is operating unless the Airport Manager and the Fire Marshal has granted prior written permission. (l) In an emergency resulting from the failure of an onboard auxiliary power unit on a jet aircraft and in the absence of suitable ground support equipment, a jet engine mounted at the rear of the Aircraft or on the wing on the opposite side from the fueling point may be operated during fueling to provide power as long as the operation follows the safety procedures published by the operator. (2) A turbine-powered auxiliary power unit installed aboard an Aircraft may be operated during fueling provided its design, installation, location and combustion air source do not constitute a fuel vapor ignition source. k. When Aircraft are being fueled or defueled, the Refueling Vehicle shall be bonded to the Aircraft to equalize the voltage potential between the Refueling Vehicle and the Aircraft. All hoses, nozzles, spouts, funnels and appurtenances used in fueling and defueling operations shall be FM or UL approved and shall be equipped with a bonding device to prevent ignition of volatile liquids. l. Refueling Vehicle operators shall not operate the Vehicle in reverse anywhere on the Airport unless another person ("spotter") is present and capable of monitoring and directing the movement of the Vehicle. m. Aircraft shall not be fueled or defueled while passengers are on board unless a passenger loading ramp is in place at the Aircraft cabin door, the door is in the open position, and an attendant is present at or near the door. n. The City assumes no liability or responsibility for violations of any applicable fueling requirements and procedures. (1) The Operator or Lessee shall be solely responsible for any violation incident to or in connection with the Operator's or Lessee's fuel storage facilities, Equipment, operations and training. (2) The Operator or Lessee shall reimburse the Airport for any fines, legal or court costs incurred by the Airport for such violations. o. Storage of Refueling Vehicles. Refueling Vehicles shall be stored outdoors and not less than fifty (50) feet from a building (or at a distance approved by the Fire Marshal) unless building is designed, constructed and used exclusively for that purpose. Refueling Vehicles shall be parked in a manner that provides a minimum of ten (10) feet of separation between Vehicles and any other Vehicle or Aircraft or within 20 feet of a storm water inlet. p. Operator or Lessee shall document and maintain Vehicle maintenance and Agency inspection records. These records shall be made available to the Airport upon request. q. Refueling Vehicles and Equipment. Refueling Vehicles, fueling pumps, meters, hoses, nozzles, funnels, fire extinguishers and bonding devices used during fueling operations shall be maintained in a safe operating condition and in good working order and repair at all times. (1) When said Refueling Vehicle(s) or Equipment is found in a state of disrepair or malfunction and the use constitutes an undue fire or safety hazard, or is in violation of any Regulatory Measure, the Operator shall discontinue the use of such Vehicles and/or Equipment until repairs, replacements, or changes are made to render the same safe for continued use. (a) Hoses and/or piping connections shall be secured and capable of holding under pump's rated PSI discharge. (b) Hoses and/or nozzles shall be FM or UL approved with self-closing valves and no "hold-open" devices. (c) All pumps shall be FM or UL approved. (d) All storage tanks shall be rated in accordance with UFC Article 24, Division II and Article 79, Division XII. r. Any malfunction or irregularity detected on or within the Aircraft being refueled or defueled should be brought to the attention of the Aircraft Operator immediately. s. Refueling Vehicles, Equipment and fuel storage facilities shall be placarded, marked and/or color coded in accordance with NFPA Publication 407 and applicable FAA Advisory Circulars. A copy of all applicable permits, registrations, certificates and insurance documents shall be maintained in each Refueling Vehicles. t. Adequate and proper fire extinguishers shall be immediately available during all fueling and defueling operations. (1) At least two (2) carbon dioxide (or approved dry chemical) fire extinguishers (20 pounds or larger) or the types of fire extinguishers that are capable of extinguishing Category B and Category C fires shall be immediately available. (2) All extinguishers shall be inspected and certified as required by law and all personnel involved with fueling or defueling operations shall be properly trained on the use of fire extinguishers. u. Adequate and proper absorbent and fuel spill containment capable of damming or diking a fuel spill shall be immediately available at all times. (1) Each Refueling Vehicle shall have a minimum 15-gallon spill kit. (2) Each fuel storage facility shall have a minimum 55-gallon spill kit. v. All hoses, funnels and appurtenances used in fueling and defueling operations shall be equipped with a bonding device to prevent ignition of volatile liquids. w. Refueling Vehicles and Vehicles utilized to deliver fuel to the fuel storage facility shall be subject to inspection by the Airport Manager at any time to determine compliance with these Rules and Regulations. x. The maintenance and operation of fuel storage facilities shall meet NFPA 30, NFPA 407 and FAA regulations, and shall be approved by all Agencies who regulate the maintenance and operation of fuel storage facilities. Further, the installation of all tanks and/or facilities shall meet the requirements of the Uniform Fire Code, Article 24.
Ask a question about Hayward law
Corpus searches the Hayward sections it holds and shows the ones that match, with their citations. Free, no sign-in.