Sec. 2-13-7. - Facility siting criteria and permitting requirements.

The following siting criteria have been established for use by hazardous waste facility project proponents in locating and designing suitable facility sites and appropriate facilities, and by the City in evaluating proposed sites and facility projects. The purpose of the criteria is to reduce public health and environmental risks and governmental costs associated with development of 1988 Orange County hazardous waste management plan, table V-3. A. Protect the residents of Orange County (and Irvine). 1. Health and safety assessment. a. All facilities. Facilities shall be sited so as not to create significant risks or cause adverse impacts to the health and safety of populations in surrounding public and private areas, as determined by a health and safety assessment. A health and safety assessment by a qualified preparer is required for a proposed facility prior to approval of a local permit, to provide technical and environmental evaluation of the proposed facility, site, and surrounding area. A health and safety assessment will provide the information and analysis needed to demonstrate compliance of the proposed facility with the siting criteria. The scope of the assessment will vary according to the size, type and proposed location of the facility. It is not intended that the health and safety assessment duplicate information developed for environmental impact reports or risk assessments required under local, State or federal regulations. When environmental impact reports and health risk assessments are required, their scopes should provide the information and analysis required, and thereby suffice for the health and safety assessment. b. The health and safety assessment shall evaluate, at a minimum, the area within 2,000 feet of the site, which is designated a sensitive area, and shall evaluate the potential impact on sensitive populations. Sensitive populations include residential populations, employment populations, and immobile populations such as those in schools, hospitals, convalescent homes, jails and other similar facilities within the area of potential impact. The health and safety assessment must consider the quantities and the physical and chemical characteristics of the specific types of waste that would be handled, the facility design features and planned operational practices. The need and distance for any buffering of the facility from residential areas or other sensitive land uses will be identified. The assessment must include a hydrologic evaluation, and must assess risks due to physical hazards such as flooding and earthquakes and potential water or air pollution. The assessment will detail credible potential accidents, including the distance over which effects would carry a variety of options for reducing risks, and procedures for dealing with the effects. The assessment will identify the capabilities (including equipment and trained personnel) and response times of existing emergency services with regard to accidents at the facility, and will provide an emergency evacuation plan. If existing emergency services are deemed inadequate, the local agency may require the developer to supplement those services with on-site trained personnel and equipment. c. Avoidance or mitigation of potential significant health or safety risks must be demonstrated to the satisfaction of the local permitting agency and the California Department of Health Services. 2. Distance from populations. a. Treatment, recycling and collection facilities. Facilities shall comply with local minimum Zoning Code setbacks, unless a greater buffer distance from other uses is deemed necessary, based on a required health and safety assessment. b. Residuals repositories. A minimum buffer distance of 2,000 feet from residences and other sensitive land uses is required for a hazardous waste residuals repository per Health and Safety Code § 25202.5(b) and (d). The size of the buffer zone necessary to protect public health and safety will be identified based on a required health and safety assessment. B. Ensure the structural stability of the facility. 1. Floodplains. a. All facilities. Facilities must be designed, constructed, operated and maintained to preclude failure due to flooding, per flood control authorities and requirements. Provisions must be made to contain and test storm runoff prior to discharge in areas subject to contamination by waste or treated material. The required health and safety assessment will address flooding risks associated with the facility. b. Treatment, recycling and collection facilities. Facilities may be located in areas subject to 100-year flooding only if protected by offsetting engineered improvements, such as berms or raising the facility above flood levels. This includes areas subject to flooding by dam or levee failure and natural causes such as river flooding, flash floods, rainfall or snowmelt, tsunamis (tidal waves), seiches (earthquake-induced waves in lakes), and coastal flooding. A structural analysis or engineering design study must be provided which shows methods to prevent inundation or washout. c. Residuals repositories. Repositories are prohibited from locating in floodplain areas subject to 100-year flooding from natural causes or dam failure, even with protection, per Code of Federal Regulations (CFR) Title 40, Section 264.18(b), and California Code of Regulations Title 22, Section 66264.18(b). 2. Earthquakes. a. All facilities. Facilities must have a minimum 200-foot setback from active or recently active earthquake faults, per California Code of Regulations Title 22, Section 66264.18(a). The required health and safety assessment will address earthquake safety of the facility. 3. Unstable soils. a. Treatment, recycling and collection facilities. Facilities are prohibited from locating in areas of potential rapid geologic change, unless the facility and its containment structures have engineered design features to assure structural stability. This includes areas with unstable soils, steep slopes, and areas subject to liquefaction, subsidence or other severe geologic constraints. The required health and safety assessment will include a geologic report defining any such constraints and engineered solutions. b. Residuals repositories. Repositories are prohibited from locating in areas of potential rapid geologic change, subsidence, or liquefaction per California Code of Regulations Title 23, Subchapter 15, Section 2531(e). The required health and safety assessment will include a geologic report. C. Protect surface and groundwater quality. 1. Containment and groundwater monitoring. a. All facilities. Facilities shall be fully enclosed by containment structures of impermeable materials which would contain any unauthorized release of hazardous material. Facilities shall be equipped with leak detection and spill control and recovery capability. Groundwater monitoring wells must be located around each facility to determine background vadose zone and groundwater quality, and to detect leaks and spills from the facility, unless demonstrated to be safe without them through the health and safety assessment. An ongoing groundwater monitoring program should be developed in consultation with local, State and water district representatives. 2. Water quality. a. All facilities. Facilities shall not be sited within watershed areas which flow to open reservoirs or aqueducts that contain drinking water supplies. Facilities shall locate such that domestic water supply wells cannot be adversely affected from unauthorized releases of contaminants. As a guideline, facilities should locate at least one mile from domestic supply wells in the Forebay area (principal recharge area to the Orange County groundwater basin), and at least one-half mile from domestic supply wells in the pressure area of the Orange County groundwater basin, unless demonstrated to be safe at closer proximity through the health and safety assessment. Facilities shall not locate within wellhead protection zones as identified by EPA guidelines or municipal water supply agencies and local water districts, unless demonstrated to be safe at closer proximity through health and safety assessment. Facilities shall not impact the quality of surface waters (lakes, rivers, streams, creeks, etc.) or groundwater resources which have been identified for beneficial uses by the Regional Water Quality Control Board basin plan (per State Water Resources Control Board Policy Resolution 88-63). The required health and safety assessment will identify water quality issues. Facilities must meet federal, State and local water quality requirements. b. Treatment, recycling and collection facilities. Facilities are encouraged to locate outside of structured principal recharge areas to regional aquifers as defined in local or State plans, including the Forebay area. Facilities may locate in the following areas only with increased engineered design features such as horizontal and vertical containment and monitoring systems to ensure protection: (a) major aquifer recharge areas, (b) areas of permeable strata and soils, (c) areas where the existing groundwater has beneficial uses as described in the basin plan. Facilities with subsurface storage or treatment must be sited, designed and operated to ensure that hazardous materials will be above the tension-saturated zone. c. Residuals repositories. Repositories are prohibited from locating in principal recharge areas to regional aquifers as defined in local or State plans, including the Forebay area. Repositories are prohibited in areas of high permeability (such as sand and gravel) per the requirements of the State Water Quality Control Board and California Code of Regulations Title 23, Subchapter 15, Section 2531(b). Repositories may locate only where the uppermost water-bearing zone or aquifer is presently mineralized (by natural or man-induced conditions) to the extent that it is not considered for beneficial use by the basin plan. Repositories must be sited, designed and operated to ensure that hazardous materials will always be above the tension-saturated zone. 3. Wastewater. a. All facilities. Facilities operating wastewaters should locate in areas with adequate industrial sewer capacity. The quality of wastewater must meet all federal, State and local sewering agency discharge requirements; and the facility must obtain a valid industrial wastewater discharge permit. D. Protect air quality. 1. Air quality nonattainment and PSD areas. a. All facilities. Facilities are prohibited in Class I areas as identified in the Clean Air Act, and within wilderness, national parks, memorial areas and similarly dedicated areas. Facilities may be sited in other nonattainment and PSD (prevention of significant deterioration) areas only if they meet the requirements of the South Coast Air Quality Management District. The required health and safety assessment will identify air emissions, impacts and mitigations associated with the facility. E. Protect environmentally sensitive areas. 1. Wetlands. a. All facilities. Facilities are prohibited from locating in wetlands such as saltwater, freshwater and brackish marshes, swamps and bogs, as defined in local, regional and State plans and policies (generally, areas inundated by surface water or groundwater with a frequency to support, under normal circumstances, a prevalence of vegetative or aquatic life which requires saturated soil conditions for growth and reproduction). 2. Animal and plant habitats. a. All facilities. Facilities are prohibited from locating within critical or significant habitat areas of animal and plant species (including threatened or endangered species), as defined in local, regional or State plans and policies. 3. Prime agricultural lands. a. All facilities. Facilities are prohibited from locating on prime agricultural lands, as defined in California law and local plans, unless an overriding public need is served and demonstrated. 4. Recreational, cultural and aesthetic resources. a. Collection facilities. Low-volume transfer and storage facilities may locate in protected, recreational, cultural or aesthetic resource areas, as defined by local, regional, State or national plans or policies, only if necessary to handle hazardous wastes generated by workers, residents, or visitors in these areas. b. Treatment and recycling facilities and residuals repositories. Facilities are prohibited from locating in protected recreational, cultural and aesthetic resource areas, as defined by local, regional, State or national plans or policies. 5. Mineral resource areas. a. All facilities. Facilities are prohibited from locating on lands containing significant mineral deposits, as classified by local plans or California's mineral land class maps and reports, if the extraction of the mineral deposit would be precluded. F. Ensure safe transportation of hazardous waste. 1. Proximity to waste generation areas. a. Treatment, recycling and collection facilities. Facilities should locate close to sources of hazardous waste generation (generally industrial areas) to minimize the risks of transportation. b. Residuals repositories. Repositories may be located more distance from the sources of hazardous waste generation than other facilities because of the need for larger land areas and buffer zones. 2. Proximity and access to major routes. a. All facilities. Facilities shall locate to minimize distance from major transportation routes. Facilities must have good access by roads designed to accommodate heavy vehicles. Travel routes from facilities to major transportation routes shall not pass through residential neighborhoods, shall minimize residential frontages, and shall be demonstrated as safe with regard to road design and construction, accident rates, excessive traffic, etc. The required health and safety assessment will evaluate risks associated with transportation of hazardous wastes. G. Protect the social and economic goals of the community. 1. Consistency with General Plan. a. All facilities. Facilities must be consistent with local planning policies, including the City or County General Plan and zoning ordinances. 2. Fiscal impact. a. All facilities. A facility's fiscal impact to the City or County must be demonstrated. 3. Socioeconomic impacts. a. All facilities. The City or County may require the facility developer to fund an independent study on socioeconomic impacts of the facility. 4. Consistency with Orange County hazardous waste management plan. a. All facilities. Facilities shall be consistent with the goals and policies of the Orange County hazardous waste management plan, and must demonstrate compliance with the siting criteria established herein. Facilities shall be consistent with the fair share principle, and with any interjurisdictional agreements on hazardous waste management. Local needs are to be the primary basis for facility siting criteria decisions, along with regional commitments; facilities are to be designed and sized primarily to meet the hazardous waste management needs of Orange County, or to meet the County's broader regional commitments under an interjurisdictional agreement.

(Code 1976, § V.E-208.6; Ord. No. 92-3, 4-14-92; Ord. No. 94-7, § 3, 6-14-94; Ord. No. 00-02, § 4, 2-8-00)

Ask a question about Irvine law

Corpus searches the Irvine sections it holds and shows the ones that match, with their citations. Free, no sign-in.