Sec. 3-37-31. - 5.2 IBC Industrial.

A. Intent. It is the intent of this section to preserve a viable industrial base in the IBC and to protect nonindustrial land uses from the nuisances and hazards often associated with industrial activities, by establishing an exclusively industrial district. The area designated for this district has historically been exclusively industrial, and is currently unsuitable for most nonindustrial uses (e.g., residential, retail). B. Permitted uses. GLU 1 Category | Use 35 | Accessory use 36 | Agriculture (interim use) 34 | Caretaker's quarters 31 | Domestic animal care facility 11 31 | Equipment rental 30 | Greenhouse 29 | Information center 29 | Industry, service 35 | Manufactured structure permit (up to two years) 30 | Manufacturing, light 29 | Office, administrative, business, professional 13 29 | Office, design professional 31 | Outdoor vendor 30 | Packing plants for agriculture products 36 | Park 36 | Pushcart 30 | Recreational vehicle storage, public 36 | Reverse vending machine 35 | School, public 35 | Sexually oriented business 30 | Vehicle assembly 31 | Vehicle repair 30 | Vehicle storage 30 | Warehousing 14, 15, 16 35 | Wireless Communication Facility (may require a wireless communication facility permit, a minor conditional use permit, a major conditional use permit or may be prohibited, depending on the type of installation and the location of the installation site, pursuant to the review procedures matrix in Section 2-37.5-3. C. Conditional uses. GLU 1 Category | Use 29 | Ambulance service 31 T | Carwash 29 | Child care center 35 | Churches (and other Places of Worship) 2 31 T | Convenience, liquor store 35 T | Community facility 30 | Composting facility 30 T | Concrete recycling facility 35 T | Drive-thru 31 T | Gas station/fuel dispenser 35 T | Government facility 30 T | Hazardous waste facility 36 | Heliport 38 | Hotel, extended stay 32 | Hotel, motel 30 T | Large collection facility 30 | Logistics uses 16 35 | Manufactured structure permit (over two years) 30 | Manufacturing, heavy 30 T | Materials recovery facility 31 | Outdoor sales 35 | Outdoor storage 31 T | Restaurant 3 31 T | Restaurant (fast food, except drive-thru) 31 T | Restaurant, "Type 47" ABC License operating after 12:00 a.m. 31 T | Retail and/or service business, general (except drive-thru) 37 | Self-storage facility 33 | Senior housing 12 32 | Single room occupancy (SRO) 30 | Small collection facility 31 T | Solid waste transfer station 30 T | Truck terminal 35 | Utility building and facility 30 | Vehicle body repair, paint or restoration 30 | Vehicle impound yard 31 | Vehicle leasing and rental 31 | Vehicle sales 30 | Vehicle wrecking yard 31 | Warehouse and sales outlet 16 Any other use which the Planning Commission finds consistent with the purpose and intent of this District and which is found to be compatible with adjacent planned and/or existing land uses. D. Maximum building intensity. 1. The IBC land use database specifies maximum development allocations in a.m. and p.m. peak hour and average daily development intensity values for each legal parcel or site. It also identifies the existing gross square feet, number of dwelling units and hotel rooms for each legal parcel in the IBC. In addition, the database estimates the build-out potential based on the 0.25 FAR in office equivalency for each site. Developments shall not exceed the allocated a.m. and p.m. development intensity values specified in the database for a particular site. 2. No tenant shall have more than 15 percent of the gross square footage of their use devoted to accessory offices use in support of the primary industrial use. E. Minimum site size. One acre. 4 F. Maximum site coverage:5 65 percent. G. Maximum building height. 35 feet. 6 H. Landscaping. 1. Site landscaping. A minimum of 15 percent landscaping is required for each improved building site. I. Setbacks. 1. Streetside setbacks: 40 feet. 7, 8 2. Side setbacks: 10 feet. 8, 9 3. Rear setbacks: 0 feet. 10 4. Improvements permitted within the setback area: a. Steps, and open and unenclosed stairways, except that they may not be located within 10 feet of the streetside property line. b. Architectural projections such as eaves, columns and buttresses may extend six feet into a 30-foot setback, and three feet into a setback less than 30 feet. 5. Setbacks for structures built over public streets: a. Intent: Structures spanning public street rights-of-way require special design considerations. This section is intended to serve several purposes. The first of these is to ensure that a tunnel-like effect is avoided along public street rights-of-way, even if structures such as bridges are developed on a series of properties. In addition, such developments are intended to observe setback requirements consistent with those applied to all other structures in the area. Finally, these regulations are intended to ensure that adequate vertical clearance for vehicular traffic across the impacted street rights-of-way is maintained. b. Buildings which are located on either side of a public street must maintain the following setbacks and clearances: (1) The vertical plane of the building which faces the street must be at or outside the required building setback from that street. (2) A clearance of at least 20 feet from the surface of the roadway to the underside of the bridge or usable floor area must be maintained. Signs shall be provided on bridges indicating the vertical clearance from the street. (3) If more than one bridge is proposed over the same street, the bridges can be no closer together than the width of the two bridges added together. (4) This section does not apply to pedestrian and/or bicycle overcrossings. J. Sidewalks. Sidewalks shall be installed along all street frontages in the planning area in accordance with the sidewalk plan for the Irvine Business Complex adopted by the City of Irvine. Additional sidewalks and other pedestrian access facilities shall be required as needed to facilitate pedestrian circulation between places of employment, restaurants, parks, and institutional, retail and residential uses. K. Lighting. 1. Exterior lighting is required for all employee and visitor parking areas, walkways, and building entrances and exits. 2. No light standard shall exceed ten feet in height unless the light standard has a light cutoff of 90 degrees or less, in which case the maximum height shall be 30 feet. 3. No light source shall be affixed to any building so that rays are perpendicular to the building face. 4. All direct rays shall be confined to the site. L. Screening. 1. All building operating mechanical equipment shall be screened from offsite view. All outside storage areas shall be screened with an opaque wall or fence. M. Parking. Parking shall be provided in accordance with Division 4 of the zoning ordinance except for the following: 1. In no instance shall the City require parking to exceed one space per 500 square feet for an industrial, storage, or warehouse use. 2. For mixed use buildings, each use shall have parking as per the requirements of the City's zoning ordinance. Those portions devoted to an industrial, storage or warehousing use shall not exceed one space per 500 square feet of gross floor area. 3. Vehicle parking shall not be permitted within the streetside setback where the property abuts a street designated as a special landscaped street, or within ten feet of the ultimate right-of-way line for property along other streets. Footnotes: T A traffic study is required for this use; see Section 9-36-11. 1 General land use (GLU) categories identify the development intensity values used for analyzing a corresponding permitted or conditional use in the IBC. See Section 9-36-8 for additional information regarding development intensity values for each general land use category. 2 A church that proposes to locate in an existing permanent building and meets all the general development standards will require an administrative use permit (AUP). However, churches which do not meet all the general development standards, or are proposed with permanent child care or private school activities, shall be subject to a conditional use permit. 3 A restaurant that proposes to locate in an existing building previously approved for restaurant use, and meets all the general development standards, including parking, will not require a conditional use permit. 4 This requirement shall not be construed to prevent condominium-type developments which have smaller lot sizes as long as they have a mandatory owners' association, and the land area under the jurisdiction of the owners' association meets the minimum lot size requirements. 5 In projects which include a parking structure, those portions of the structure which meet the following criteria shall not be counted in determining compliance with the limits on building site coverage: a. The roof of the structure is within five feet of the surface grade existing on the site prior to the development of the project; and b. The roof of the structure is, in effect, replacing the ground surface in the functions that it performs, i.e., it will be covered by such improvements as surface parking, access drives, landscaping, walkways, and plazas in a manner similar to the design that would be used if the roof were land surface; and c. Any portion of the parking structure which is above the existing grade is screened from off-site views. 6 The height of equipment or machinery which is necessary to the operation of a permitted use may exceed 35 feet but may not exceed FAA height limits. 7 If the ultimate right-of-way for a street is widened subsequent to June 30, 1982, then the minimum setback may be 30 feet from the right-of-way/property line. This provision shall not be construed to allow existing structures to expand by virtue of the reduced setback. 8 Transfer station and material recovery facility enclosure setbacks to be determined by the Planning Commission at time of CUP review. 9 May be zero feet provided that the main building on the abutting lot is at zero feet, and both parcels are developed at the same time. 10 Any parcel with two or more street frontages may have one interior property line with a setback of zero feet. 11 Domestic animal care facilities shall require a veterinary certificate of health and proof of current vaccinations for distemper, rabies and parvovirus. Animals may be groomed, trained, exercised, socialized and kept or boarded overnight, but not bred, sold or let for hire. 12 A conditional use permit and/or master plan are required for senior housing. 13 An administrative use permit (AUP) is required for online vehicle sales offices. 14 Use is permitted by right when equal to or less than 175,000 square feet of the building's gross square footage is used for warehouse purposes and located within the designated flight hazard zone for John Wayne Airport located west of Mac Arthur Boulevard and west of Red Hill. A traffic study shall be required for this use, and it shall be required for this use, and it shall identify specific on-site and off-site circulation improvements necessary to mitigate the impacts of the projected future development, which shall be implemented prior to and concurrent with the project's construction. In the event identified circulation improvements are not timely constructed, permits required for the project may be withheld and/or a project may be subject to code enforcement or other legal action. 15 Use requires an administrative use permit when 175,001 to 225,000 square feet of the building's gross square footage is used for warehouse purposes and a conditional use permit when equal to or more than 225,001 square feet of the building's gross square footage is used for warehouse purposes and located within the designated flight hazard zone for John Wayne Airport located west of Mac Arthur Boulevard and west of Red Hill. 16 As determined by the City of Irvine, a traffic analysis shall be submitted to determine if on-site and off-site improvements must be made conditions of the project's discretionary approval.

(Code 1976, § V.E-325.5.2; Ord. No. 92-3, 4-14-92; Ord. No. 92-21, § 6, 11-24-92; Ord. No. 93-7, 6-22-93; Ord. No. 93-14, § 3, 10-12-93; Ord. No. 94-2, § 3, 2-8-94; Ord. No. 94-7, § 3, 6-14-94; Ord. No. 94-15, § 3, 12-13-94; Ord. No. 94-16, 12-13-94; Ord. No. 95-3, § 3B, 4-25-95; Ord. No. 95-4, § 1, 5-9-95; Ord. No. 95-7, § 4, 7-11-95; Ord. No. 95-8, § 3, 7-11-95; Ord. No. 95-12, § 3, 9-12-95; Ord. No. 95-16, § 2, 10-10-95; Ord. No. 96-2, § 2, 1-23-96; Ord. No. 96-18, § 4, 12-10-96; Ord. No. 98-20, § 2, 12-8-98; Ord. No. 99-10, § 3, 5-11-99; Ord. No. 99-14, § 2, 6-8-99; Ord. No. 05-13, § 4, 7-12-05; Ord. No. 05-16, § 2, 7-12-05; Ord. No. 10-04, § 3, 4-13-10; Ord. No. 10-07, § 9 (Exh. E), 7-27-10; Res. No. 15-86, § 3(Exh. A), 8-11-15; Ord. No. 24-07, § 3(Exh. A), 5-28-24; Ord. No. 24-13, § 2(Exh. A), 9-10-24; Ord. No. 25-06, § 2(Exh. A), 4-8-25; Ord. No. 25-18, § 2(Exh. A), 6-24-25; Ord. No. 26-01, Exh. A, 2-10-26)

Ask a question about Irvine law

Corpus searches the Irvine sections it holds and shows the ones that match, with their citations. Free, no sign-in.