§ 3-8.5-3 — Objective concealment standards
Irvine Municipal Code (Supp. No. 20: codified through Ordinance No. 26-05, adopted February 10, 2026) · Irvine Zoning Ordinance § 3-8.5-3
Corpus is an independent public-information project, not the official City of Irvine website. Stable reference: corpuslaw.us/code/45046514-0cf8-43ed-8b5a-00d7012aa09e
Sec. 3-8.5-3. - Objective concealment standards.
By definition, eligible facilities requests impact a pre-existing eligible support structure that falls under one of the classifications found in Section 2-37.5-3 of this Code. Objective Concealment Standards have been developed in order to ensure that a proposed modification does not defeat the concealment elements of the eligible support structure, and thus qualifies for an eligible facilities permit. These standards are meant to ensure that a modified facility includes camouflage elements/techniques that match the conditions of the existing facility in a manner consistent with the underlying approval. These standards shall not be construed to suggest that a modified facility is to be enhanced beyond the existing concealment elements already in place for a facility, so long as the existing concealment elements comply with the underlying approval. The following Objective Concealment Standards shall apply to any modification requiring an eligible facilities permit issued pursuant to Chapter 2-37.6: 1. Class 1 (Building Mount). For an eligible facilities permit that impacts Class 1 facilities, the following objective concealment standards shall apply: • Facility components shall be mounted either inside the structure or entirely behind the proposed screening elements, including all antenna panels. • Screening materials shall be integrated with the building and match in color, size, proportion, style, texture and quality with the exterior design and architectural character of the structure and the surrounding visual environment. • A design which results in an installation that is camouflaged and minimizes the visual impact to the surrounding area. • All accessory equipment shall be located inside the existing equipment enclosure, building, or roof of the building provided it is fully concealed. If mounted inside the equipment enclosure or roof, all appurtenances shall be located below the top of wall or roofline/parapet. • All new utility lines shall be flush mounted on the roof surface and/or located underground and within the existing lease area. • All new roof mounted equipment shall be located below the roof or parapet and behind RF screening that is architecturally compatible and consistent with the design of the building or structure. 2. Class 2 (Monorock/Monoshrub). For an eligible facilities permit that impacts Class 2 facilities, the following objective concealment standards shall apply: • Wireless components mounted inside the concealment element. • All new utility lines located underground and within the existing lease area. • For a monoshrub, screening materials that match other vegetation in the immediate vicinity of site. New comparable living vegetation may be necessary to enhance the monoshrub screen. For monorocks, screening that shall match in color as other rock outcroppings in the general vicinity of the proposed site. • All accessory equipment shall be located inside the existing equipment enclosure. 3. Class 3 (Streetlights/Traffic Signals/Utility Poles). For an Eligible Facilities Permit that impacts Class 3 facilities, the objective concealment measures and submittal requirements outlined in Chapters 2-36 and 3-40 for Small Utility Facilities shall apply. 4. Class 4 (Co-Location). For an eligible facilities permit that impacts Class 4 facilities, the applicable objective concealment standards are determined by the type of installation and classification being used for the co-location. For example, a co-locatable mono-euc shall apply the Class 10 concealment elements. 5. Class 6 (Visible Field Lights/Utility Towers/Streetlights/Traffic Signals). For an eligible facilities permit that impacts Class 6 facilities, the following objective concealment standards will apply: • The radome shall be painted or otherwise coated to be visually compatible with lighting and signal equipment (right-of-way facilities only). • Antenna panels and accessory equipment shall be located and arranged on the structure so as to replicate the existing appearance of the installation and any equipment already mounted to the structure. • Antenna panels or other equipment shall be wired in a manner minimizing exposed cables. The use of 90-degree connectors may be used to prevent dangling cables. • All antennas, mounting hardware, cabling, nuts and bolts, and other equipment (including remote radio units and tower mounted amplifiers) shall be painted to match the tower. • All cabling shall be installed flat against the tower to the extent possible. The concealment measures applied to the facility shall result in an installation consistent with existing concealment elements. • All accessory equipment shall be located inside the existing equipment enclosure. All appurtenances shall be located below the top of wall of the enclosure. • All new utility lines located underground and within the existing lease area. • A design that screens the installation from direct view from surrounding properties. 6. Class 7 (Flagpole Mount). For an eligible facilities permit that impact Class 7 facilities, the following objective concealment standards shall apply: • All antenna panels and accessory equipment shall be mounted inside the tower. • Screening materials shall match the size, color, texture and design of the existing tower. • All accessory equipment shall be located inside the existing equipment enclosure. All appurtenances shall be located below the top of wall. • All new utility lines located underground and within the existing lease area. 7. Class 8 (Building Mount, Visible). For an eligible facilities permit that impacts Class 8 facilities, the following objective concealment standards shall apply: • Antenna panels and cabling shall be installed flat against the building to the extent possible. • Antenna panels shall match the color of the existing antenna panels on the building. • Antenna panels mounted below the top of the roof and arranged on the building so as to replicate the existing appearance of the installation and any equipment already mounted. • Antenna panels or other equipment shall be wired in a manner minimizing exposed cables. • All antennas, mounting hardware, cabling, nuts and bolts, and other equipment (including remote radio units and tower mounted amplifiers) shall be painted to match the color of the building. • A design which results in an installation consistent with existing concealment elements. All accessory equipment shall be located inside the existing equipment enclosure, building, or roof of the building provided it is fully concealed. If mounted inside the equipment enclosure or roof, all appurtenances shall be located below the top of wall of the enclosure or below the roofline of the building. • All new utility lines flush mounted to the roof surface. 8. Class 9 (Enclosed Camouflaged Tower). For an eligible facilities permit that impacts Class 9 facilities, the following objective concealment standards shall apply: • All antenna panels and accessory equipment shall be mounted inside the tower. • Screening materials shall match in color, size, proportion, style, texture and quality with the exterior design and architectural character of the structure and the surrounding visual environment. • All accessory equipment shall be located inside the existing equipment enclosure. All appurtenances shall be located below the top of wall of the enclosure. • All new utility lines located underground and within the existing lease area. 9. Class 10 (Monopole, Exterior Mount). For an eligible facilities permit that impacts Class 10 facilities, the following objective concealment standards shall apply: • All antenna components and support equipment shall be treated with exterior coatings of a color and texture that matches the existing wireless facility. • Antenna panels and accessory equipment shall be located and arranged on the structure so as to replicate the existing appearance of the installation and any equipment already mounted to the structure. • A branch density to match the existing tree. • Antenna covers of a durable material shall be applied to match the color of the tree and embedded with leaves matching the leaf density of the tree. • Tree branches shall be used that extend a minimum three feet beyond antenna panels and support equipment. • All antennas, mounting hardware, cabling, nuts and bolts, and other equipment (including tower mounted amplifiers) used on the faux trees shall be painted in greens or browns to match the tree design. • All cabling shall be installed internal to the tree structure to the extent possible. • Antenna panels or other equipment shall be wired in a manner minimizing exposed cables. • All new and accessory equipment shall be located inside the existing equipment enclosure. All appurtenances shall be located below the top of wall of the enclosure. • All new utility lines located underground and within the existing lease area. 10. Class 11 (Non-Camouflage Monopole). For an eligible facilities permit that impacts Class 11 facilities, the following objective concealment standards shall apply: • All antennas, mounting hardware, cabling, nuts and bolts, and other equipment (including remote radio units and tower mounted amplifiers) shall be painted to match the tower. • Antenna panels or other equipment shall be wired in a manner minimizing exposed cables. The project may use 90-degree angle connectors to accomplish this. • Antenna panels and accessory equipment shall be located and arranged on the structure so as to replicate the existing appearance of the installation and any equipment already mounted to the structure. • All new accessory equipment shall be located inside the existing equipment enclosure and below the top of wall of the enclosure. • All new utility lines located underground and within the existing lease area.
(Ord. No. 16-05, § 3(Att. 1), 7-26-16; Ord. No. 19-06, § 6(Exh. A), 5-14-19)
Ask a question about Irvine law
Corpus searches the Irvine sections it holds and shows the ones that match, with their citations. Free, no sign-in.
