§ 5-2-24 — Standards of construction for flood hazard zones

Irvine Municipal Code (Supp. No. 20: codified through Ordinance No. 26-05, adopted February 10, 2026) · Irvine Zoning Ordinance § 5-2-24

Corpus is an independent public-information project, not the official City of Irvine website. Stable reference: corpuslaw.us/code/2a12038d-86b2-4e32-9718-3e9ba94b4d1a

Sec. 5-2-24. - Standards of construction for flood hazard zones.

In all areas of special flood hazards the following standards are required: A. Anchoring. 1. All new construction and substantial improvements, including manufactured structures, shall be adequately anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy. 2. All manufactured homes shall meet the anchoring standards of Section 5-2-20. B. Construction materials and methods. All new construction and substantial improvements, including manufactured structures, shall be constructed: 1. With materials and utility equipment resistant to flood damage below BFE; 2. Using methods and practices that minimize flood damage; 3. With electrical, heating, ventilation, plumbing and air conditioning equipment and other service facilities that are designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding; and 4. Within Zone AH or AO, so that there are adequate drainage paths around structures on slopes to guide floodwaters around and away from proposed structures. C. Elevation and floodproofing. (Refer to Section 1-2-1 definitions for "basement," "lowest floor," "new construction," "substantial damage" and "substantial improvement.") 1. Residential construction, new or substantial improvement, shall have the lowest floor, including basement: a. In an AO Zone, elevated above the highest adjacent grade to a height equal to or exceeding one foot above the depth number specified in feet on the FIRM, or elevated at least two feet above the highest adjacent grade if no depth number is specified. b. In an A Zone, elevated at least one foot above the base flood elevation, as determined by the Floodplain Administrator. c. In all other zones, elevated at least one foot above the base flood elevation. Upon the completion of the structure, the elevation of the lowest floor, including basement, shall be certified by a registered professional engineer or surveyor, and verified by the City of Irvine Chief Building Official, to be properly elevated. Such certification or verification shall be provided to the Floodplain Administrator. 2. Nonresidential construction, new or substantial improvement, shall either be elevated to conform with Section 5-2-24.C.1 or, together with attendant utility and sanitary facilities: a. Be floodproofed below the elevation recommended under this Section 5-2-24 so that the structure is watertight with walls substantially impermeable to the passage of water; b. Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy; and c. Be certified by a registered professional engineer or architect that the standards of this Section (5-2-24.C.2) are satisfied. Such certification shall be provided to the Floodplain Administrator. 3. All new construction and substantial improvement with fully enclosed areas below the lowest floor (excluding basements) that are usable solely for parking of vehicles, building access or storage, and which are subject to flooding, shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwater. Designs for meeting this requirement must exceed the following minimum criteria: a. Be certified by a registered professional engineer or architect; or b. Have a minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding. The bottom of all openings shall be no higher than one foot above grade. Openings may be equipped with screens, louvers, valves or other coverings or devices provided that they permit the automatic entry and exit of floodwater. 4. Manufactured homes shall also meet the standards in Section 5-2-20.

(Code 1976, § V.E-501.15; Ord. No. 92-3, 4-14-92; Ord. No. 94-7, § 3, 6-14-94; Ord. No. 95-18, § 4, 10-10-95; Ord. No. 10-04, § 3, 4-13-10)

Ask a question about Irvine law

Corpus searches the Irvine sections it holds and shows the ones that match, with their citations. Free, no sign-in.