Sec. 6-8-203. - Noise level measurement criteria.
A. Any noise level measurements made pursuant to the provisions of this chapter shall be performed using a sound level meter. B. The location selected for measuring exterior noise levels shall be at any exterior part of the receiving property, except for private residential balconies, decks, roof decks, or other exterior areas only accessible through a private residence. C. The location selected for measuring exterior noise levels in a nonresidential area shall be at any point on a receiving property, 5-feet above finish grade, no closer than five-feet from any wall. D. Any noise level measurement made pursuant to the provisions of this chapter shall be based on a reference sound pressure of 20 micropascals as measured with a sound level meter using the A-weighted network (scale) at slow response. E. Noise measurements shall be taken over a minimum 15-minute period, or until the running average sound level variance is less than 1 dB.