For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 6-8-203 — Noise level measurement criteria

Irvine Municipal Code (Supp. No. 20: codified through Ordinance No. 26-05, adopted February 10, 2026) · Irvine Municipal Code § 6-8-203

Corpus is an independent public-information project, not the official City of Irvine website. Stable reference: corpuslaw.us/code/753a89e7-07e7-4f9b-bf3c-62d73c8098c9

Sec. 6-8-203. - Noise level measurement criteria.

A. Any noise level measurements made pursuant to the provisions of this chapter shall be performed using a sound level meter. B. The location selected for measuring exterior noise levels shall be at any exterior part of the receiving property, except for private residential balconies, decks, roof decks, or other exterior areas only accessible through a private residence. C. The location selected for measuring exterior noise levels in a nonresidential area shall be at any point on a receiving property, 5-feet above finish grade, no closer than five-feet from any wall. D. Any noise level measurement made pursuant to the provisions of this chapter shall be based on a reference sound pressure of 20 micropascals as measured with a sound level meter using the A-weighted network (scale) at slow response. E. Noise measurements shall be taken over a minimum 15-minute period, or until the running average sound level variance is less than 1 dB.

(Code 1976, § VI.K-303; Ord. No. 84-18, 9-11-84; Ord. No. 23-25, § 1(Exh. A), 12-12-23)

Ask a question about Irvine law

Corpus searches the Irvine sections it holds and shows the ones that match, with their citations. Free, no sign-in.