§ 15.20.200 — Minimum water well production
Municipal Code of the City of Jurupa Valley, California (Codified through Ordinance No. 2026-12, enacted October 1, 2026 (Supp. No. 28)) · Jurupa Valley Municipal Code § 15.20.200
Corpus is an independent public-information project, not the official City of Jurupa Valley website. Stable reference: corpuslaw.us/code/c2c5605a-07e7-4a3c-9c95-5fba9b3c98e6
Sec. 15.20.200. - Minimum water well production.
A. All individual domestic water wells providing drinking water to a residence must be tested for the purpose of achieving a minimum level of water production capability. B. Water production testing shall be performed under the direct supervision of a California licensed C-57 well driller, C-61 pump contractor, D-21 pump contractor or a certified hydrogeologist. The testing shall include the following requirements: (1) Standing water level measurements in the individual domestic water well shall be made immediately prior to the start of pumping. The standing water level shall be measured to an accuracy of at least one-tenth (0.1) of one (1) foot. (2) Timing of the test shall commence from the start of pumping or when an air lift is started. Pumping shall continue on an uninterrupted basis for a minimum two (2) hour period until three (3) or more wetted bore volumes of water have been discharged from the well. The term "wetted bore volume" is defined to mean the volume of the well hole below the standing water level measurement. In those cases that involve screened and filter packed wells, the volume of water contained in the filter pack shall also be included in the bore volume calculation. (3) Water production shall be kept at a constant rate of no less than one (1) gallon per minute per residence or unit. Higher production rates may be required based upon the proposed water usage and as determined by the Department. This level of production applies to new water wells used for domestic purposes and existing water sources on property being improved. (4) Water discharged from the water well during the production test shall be restricted so that it does not re-enter the water well that is the subject of the test. (5) The standing water level in the individual domestic water well shall be remeasured immediately at the conclusion of pumping. The standing water level shall be measured to an accuracy of at least one-tenth (0.1) of one (1) foot. The well shall not pump dry during the test.
Ask a question about Jurupa Valley law
Corpus searches the Jurupa Valley sections it holds and shows the ones that match, with their citations. Free, no sign-in.
