§ 57.1010.1.2.2 — DOUBLE-ACTING DOORS

Los Angeles Municipal Code (2026 Rev. 9, current through legislation effective June 30, 2026) · Los Angeles Municipal Code § 57.1010.1.2.2

Corpus is an independent public-information project, not the official City of Los Angeles website. Stable reference: corpuslaw.us/code/5eca280a-987f-4636-96e0-e1160a068383

SEC. 57.1010.1.2.2. DOUBLE-ACTING DOORS.

Double-acting doors shall not be used as exits when any of the following conditions exist: 1. The occupant load served by the door is 100 or more. 2. The door is part of a fire assembly. 3. The door is part of a smoke and draft- control assembly. 4. Panic hardware is required or provided on the door.