§ 57.2404.7.9.4 — SEPARATION FROM COMBUSTIBLE MATERIAL

Los Angeles Municipal Code (2026 Rev. 9, current through legislation effective June 30, 2026) · Los Angeles Municipal Code § 57.2404.7.9.4

Corpus is an independent public-information project, not the official City of Los Angeles website. Stable reference: corpuslaw.us/code/3665b94a-5536-4149-80e8-9072d3a4679c

SEC. 57.2404.7.9.4. SEPARATION FROM COMBUSTIBLE MATERIAL.

Ducts or pipes may be separated from combustible material by a ventilated collar which provides a clear air space equal to one-half the diameter of the duct, but in no event shall such collar provide less than 3-inch air space, and such collar shall extend not less than 12 inches above and below such combustible material.