For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 57.315.3.12.3 — SPACE UNDER STAIRWAYS

Los Angeles Municipal Code (2026 Rev. 9, current through legislation effective June 30, 2026) · Los Angeles Municipal Code § 57.315.3.12.3

Corpus is an independent public-information project, not the official City of Los Angeles website. Stable reference: corpuslaw.us/code/79ff8b92-ab26-4a32-9dff-f074fdb74259

SEC. 57.315.3.12.3. SPACE UNDER STAIRWAYS.

There shall be no enclosed usable space under stairways in an exit enclosure (enclosed stair shafts serving three or more stories), nor shall the open space under such stairways be used for any purpose. EXCEPTION: Space under exterior stairways and interior stairways shall not be used for any purpose except when the usable space under stairs is enclosed and walls and soffits are protected on the enclosed side as required for one-hour fire-resistive construction in accordance with Chapter 9 of the Los Angeles Municipal Code (Building Code).

Ask a question about Los Angeles law

Corpus searches the Los Angeles sections it holds and shows the ones that match, with their citations. Free, no sign-in.