§ 57.4705.1.7 — EMERGENCY ELEVATOR
Los Angeles Municipal Code (2026 Rev. 9, current through legislation effective June 30, 2026) · Los Angeles Municipal Code § 57.4705.1.7
Corpus is an independent public-information project, not the official City of Los Angeles website. Stable reference: corpuslaw.us/code/14fe7b33-a251-4be8-a01e-6e8b9a38a366
SEC. 57.4705.1.7. EMERGENCY ELEVATOR.
At least one elevator car serving all building levels shall be made available for emergency use and shall contain the following: 1. A minimum inside car platform of 4 feet 3 inches deep by 6 feet 8 inches wide with a minimum clear opening width of 42 inches, unless otherwise designed and approved to provide equivalent utility to accommodate an ambulance stretcher having a minimum size of 24 inches by 84 inches in its horizontal position. 2. The elevator shall be subject to control from the building control station. 3. The elevator shall be interconnected with the standby power system. 4. The elevator shall be identified with a permanent sign installed adjacent to the elevator control panel in the building control station.
Ask a question about Los Angeles law
Corpus searches the Los Angeles sections it holds and shows the ones that match, with their citations. Free, no sign-in.