§ 91.1906 — FOOTINGS FOR LIGHT-FRAME CONSTRUCTION
Los Angeles Municipal Code (2026 Rev. 9, current through legislation effective June 30, 2026) · Los Angeles Municipal Code § 91.1906
Corpus is an independent public-information project, not the official City of Los Angeles website. Stable reference: corpuslaw.us/code/99f19116-e421-49c6-9ccb-567db6169d91
SEC. 91.1906. FOOTINGS FOR LIGHT-FRAME CONSTRUCTION.
(Added by Ord. No. 188,797, Eff. 12/31/25.) Section 1906 of the CBC is adopted by reference with the following exceptions, modifications and additions: 91.1906.1. Plain Concrete Footings. The design and construction of structural plain concrete, both cast-in-place and precast, shall comply with the minimum requirements of ACI 318, as modified in CBC Section 1905 and LAMC Section 91.1905. EXCEPTION: For Group R-3 occupancies and buildings of other occupancies less than two stories above grade plane of light-frame construction, the required footing thickness of ACI 318 is permitted to be reduced to 6 inches (152 mm), provided that the footing does not extend more than 4 inches (102 mm) on either side of the supported wall. This exception shall not apply to structural elements designed to resist seismic lateral forces for structures assigned to Seismic Design Category D, E, or F.
Ask a question about Los Angeles law
Corpus searches the Los Angeles sections it holds and shows the ones that match, with their citations. Free, no sign-in.
