For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 91.2.506 — CHANGE OF OCCUPANCY

Los Angeles Municipal Code (2026 Rev. 9, current through legislation effective June 30, 2026) · Los Angeles Municipal Code § 91.2.506

Corpus is an independent public-information project, not the official City of Los Angeles website. Stable reference: corpuslaw.us/code/eecdfb7e-cd90-4ec4-8daf-13dd7a98b4d1

SEC. 91.2.506. CHANGE OF OCCUPANCY.

(Added by Ord. No. 188,797, Eff. 12/31/25.) Section 506 of the CEBC is hereby adopted by reference except as amended herein. 91.2.506.5.3. Seismic Loads (seismic force-resisting system). Where a change of occupancy results in a building being assigned to a higher Risk Category, or where the change is from a Group S or U occupancy to an occupancy other than Group S or Group U, the lateral force-resisting system of the building shall comply with CEBC Section 304.3.1 for the new Risk Category. Where a change of occupancy results in a building being assigned to Risk Category IV and Seismic Design Category D or F, nonstructural components serving any portion of the building changed to Risk Category IV shall comply with the requirements of Section 1613 of the California Building Code or shall comply with ASCE 41 using an objective of Operational nonstructural performance with the BSE-1N earthquake hazard level. EXCEPTIONS: 1. Where the area of the new occupancy is less than 10 percent of the building area, the occupancy is not changing from a Group S or Group U, and the new occupancy is not assigned to Risk Category IV, compliance with this Section is not required. The cumulative effect of occupancy changes over time shall be considered. 2. Where a change of use results in a building being reclassified from Risk Category I or II to Risk Category III and the seismic coefficient, SDS, is less than 0.33, compliance with this section is not required. 3. Unreinforced masonry bearing wall buildings assigned to Risk Category III and to Seismic Design Category A or B shall be permitted to use Appendix Chapter A1 of this code. 4. Where the change is from a Group S or Group U occupancy and there is no change of Risk Category, compliance with CEBC Section 304.3.2 shall be permitted. Reduced seismic loads, in accordance with CEBC Section 304.3.2, shall be permitted provided the reduced seismic load is not less than the original building permitted seismic loads. For a change of occupancy of an existing commercial or industrial building to residential use, all existing buildings shall be analyzed for 75 percent of the design earthquake ground motion, as defined in CBC Section 1613, but in no event shall there be a reduction in the capacity of the seismic force resisting system where that system provides a greater level of protection than the minimum requirements established by this Code. For an existing URM building, structural analysis per CBC Chapter 16 is required if the Risk Category is changed to III or IV. Structural analysis per CEBC Appendix A1 is required if rating classification per LABC Division 88, Table 88-A is changed to I or II. The most restrictive requirements of CEBC Sections 502 (Addition), 503 (Alternation), 405 (Repair) and 506 (Change of Occupancy) shall apply.

Ask a question about Los Angeles law

Corpus searches the Los Angeles sections it holds and shows the ones that match, with their citations. Free, no sign-in.