§ 8.70.310 — Standards of construction
Municipal Code, City of Lake Forest, California (Includes legislation through Ord. No. 388 adopted August 18, 2026) · Lake Forest Municipal Code § 8.70.310
Corpus is an independent public-information project, not the official City of Lake Forest website. Stable reference: corpuslaw.us/code/52e2a2d1-c694-4286-b6f5-1c915dd471a8
§ 8.70.310: Standards of construction.
In all areas of special flood hazards, the following standards are required: A. Anchoring. 1. All new construction and substantial improvements shall be anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy. 2. All manufactured homes shall meet the anchoring standards of Section 8.70.325. B. Construction Materials and Methods. 1. All new construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage, as specified in FEMA Technical Bulletin ("TB") 2 ("Flood Damage—Resistant Materials Requirements"). 2. All new construction and substantial improvements shall be constructed using methods and practices that minimize flood damage. 3. All new construction and substantial improvements shall be constructed with electrical, heating, ventilation, plumbing and air conditioning equipment and other service facilities that are designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding. 4. All new construction and substantial improvements within Zones AH or AO shall be constructed so that there are adequate drainage paths around structures on slopes to guide flood waters around and away from proposed structures. C. Elevation and Floodproofing. 1. In an AO zone, new construction for residential and nonresidential and substantial improvement of a structure shall be elevated at least one foot above the highest adjacent grade to a height equal to or exceeding the depth number specified in feet on the FIRM, or elevated at least two feet above the highest adjacent grade if no depth number is specified. Nonresidential structures may also meet the standards in subsection (C)(2) of this section. In all other SFHA zones, including zone A, new construction and substantial improvement of any structure shall have the lowest floor, including basement, elevated to at least one foot above the base flood elevation. Upon the completion of the structure, the elevation of the lowest floor, including basement, shall be certified by a registered professional engineer or surveyor, or verified by the community building inspection to be properly elevated. Such certification or verification shall be provided to the Floodplain Administrator. 2. Nonresidential construction shall either be elevated in conformance with subsection (C)(1) of this section or together with attendant utility and sanitary facilities: a. Be floodproofed so that below the base flood level the structure is watertight with walls substantially impermeable to the passage of water; b. Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy; and c. Be certified by a registered professional engineer or architect that the standards of this subsection are satisfied. Such certifications shall be provided to the Floodplain Administrator. 3. Require, for all new construction and substantial improvements, that fully enclosed areas below the lowest flood that are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit floodwaters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or meet or exceed the following minimum criteria: a. Either a minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided. The bottom of all openings shall be no higher than one foot above grade. Openings may be equipped with screens, louvers, valves, or other coverings or devices provided that they permit the automatic entry and exit of floodwaters; or b. Be certified to comply with a local flood proofing standard approved by the Federal Insurance Administration. 4. Manufactured homes shall also meet the standards in Section 8.70.325. D. Flood Openings. 1. All new construction and substantial improvements of structures with fully enclosed areas below the lowest floor (excluding basements) that are usable solely for parking of vehicles, building access or storage, and which are subject to flooding, shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwater. Designs for meeting this requirement must meet the following minimum criteria: a. For non-engineered openings: i. Have a minimum of two openings on different sides having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding; ii. The bottom of all openings shall be no higher than one foot above grade; iii. Openings may be equipped with screens, louvers, valves or other coverings or devices provided that they permit the automatic entry and exit of floodwater; and iv. Buildings with more than one enclosed area must have openings on exterior walls for each area to allow flood water to directly enter; or b. Be certified by a registered civil engineer or architect.
( Ord. 41 § 1, 1993 ; Ord. 325 § 3, 2019 ; Ord. 374 , 2/4/2025 )
Ask a question about Lake Forest law
Corpus searches the Lake Forest sections it holds and shows the ones that match, with their citations. Free, no sign-in.