§ 9.150.205 — Standards for inoperative pits, mines, etc
Municipal Code, City of Lake Forest, California (Includes legislation through Ord. No. 388 adopted August 18, 2026) · Lake Forest Municipal Code § 9.150.205
Corpus is an independent public-information project, not the official City of Lake Forest website. Stable reference: corpuslaw.us/code/6171f66e-a650-4011-abd0-d9d62f6e5a2e
§ 9.150.205: Standards for inoperative pits, mines, etc.
Each pit, mine, surface mine, or commercial extraction operation not currently in use for commercial extraction operations shall be maintained in accordance with the following minimum standards: A. Setbacks and Slopes. 1. The finished perimeter slope shall not be steeper than one and one-half (1½) feet horizontal to one foot vertical projecting into the pit from a 50 foot setback adjacent to the perimeter of the property. 2. In addition, where the Community Development Director determines there is a possibility of potentially hazardous seepage or flow into a pit from a flood control channel, reservoir, conservation or flood retarding basin, or natural watercourse, he/she shall establish the setback and slope requirements based on the preservation of the integrity of existing flood control channel, reservoir, conservation or flood retarding basin, or natural watercourse, so that the subject property shall continue to receive and carry off waters in a manner equal to that experienced prior to any excavation. Setback requirements imposed under this subsection may exceed the 50 foot requirement set forth hereinabove, in the discretion of the Community Development Director, but such setbacks may not be less than 50 feet, as set forth in subdivision 1 of this subsection. Slope requirements may be greater or less than that set forth in subdivision 1 of this subsection, in the discretion of the Community Development Director. The applicant may be required to furnish reports and engineering data, as set forth in Section 9.150.165, to justify the setback and slope requirement requested in such a case. The Community Development Director may require such reports in any case. 3. Where the Community Development Director determines that the pit, mine, mine surface, or commercial extraction operation extends below, or in the future may extend below, groundwater elevations, the slopes shall not be steeper than the safe values as determined by the Community Development Director, based on the reports described in Section 9.150.165, which reports may be required by the Community Development Director in such a case. These requirements may be modified by the Community Development Director in cases where safety conditions and engineering and geological data submitted to the Community Development Director for approval indicate that a less restrictive setback or slope may be permitted. B. Diversions. No pit shall be maintained in or adjacent to the floodplain of any watercourse which by reason of the excavation's shape, location, berm elevations, or area, in the opinion of the Community Development Director, is likely to produce a diversion of the natural watercourse away from the pit, mine, mine surface, or commercial extraction operation, and outside the natural watercourse in the event that flow from the watercourse enters the excavation. C. Drainage. Adequate provisions for conveyance of water across and from the site and for long-term retention of water shall be accomplished so as to minimize potential dangers from landslide and erosion. D. Fencing. Other than in cases where data is submitted to the Community Development Director for approval and which data indicate to the Community Development Director that no safety hazards exist, a fence shall be constructed enclosing the area of each existing pit. Said fence shall be of a steel, chain link type, and a minimum of six feet in height above the existing grade of property outside the fenced area. The bottom of said fence shall conform to the ground surface so as to prevent any opening between it and the ground surface exceeding four inches. Gates of the same material and height as the fence shall be installed at all points of vehicular or pedestrian ingress and egress. Said gates shall be equipped with keyed locks and shall be kept locked at all times when not in regular use. Said fence, gates, and locks shall be maintained in good condition and repair. E. Protective Devices, Correction, and Repair. Whenever the Community Development Director determines that maintenance of protective devices or structures, or the correction of potentially unsafe conditions may be necessary for the protection of adjacent properties or the general public, he/she shall notify in writing the owner or other responsible person, who shall take such corrective action as necessary and shall post a surety bond or other financial security in an amount sufficient to insure the continued maintenance of the protective devices for such potentially unsafe conditions. A grading permit will be required for any repair work.
( Ord. 176 § 1, 2007 )
Ask a question about Lake Forest law
Corpus searches the Lake Forest sections it holds and shows the ones that match, with their citations. Free, no sign-in.
