For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 15.22.90 — Doors: Swinging doors

Lancaster Municipal Code, City of Lancaster, California (Supp. No. 4-26: codified through Ordinance No. 1154, enacted September 8, 2026) · Lancaster Municipal Code § 15.22.90

Corpus is an independent public-information project, not the official City of Lancaster website. Stable reference: corpuslaw.us/code/508a419b-9298-4d18-9427-ff6386c111a1

15.22.90 - Doors: Swinging doors.

15.22.91 Swinging wooden doors which are operable from the inside without the use of a key shall be of one of the following constructions or shall be of a construction having equivalent forced entry resistance: 15.22.91.1 Solid core doors not less than one and three-eighths inches (35 mm) in thickness. 15.22.91.2 Wood panel type doors with panels fabricated of lumber not less than one and three-eighths inches (34.9 mm) thick, provided shaped portions of the panels are not less than one-fourth-inch (6.4 mm) thick. Individual panels shall not exceed 300 square inches (0.19 m 2 ) in area. Stiles and rails shall be of solid umber with overall dimensions of not less than one and three-eighths inches (35 mm) in thickness and three inches (76 mm) in width. Mullions shall be considered a part of adjacent panels unless sized as required herein for stiles and rails, except mullions not over eighteen (18) inches (457 mm) long may have an overall width of not less than two inches (51 mm). Carved areas shall have a thickness of not less than three-eighths-inch (9.5 mm). Dimensional tolerances published in recognized industry standards may be utilized. 15.22.91.3 Hollow core doors or doors less than one and three-eighths inches (35 mm) in thickness, either of which are covered on the inside face with 16-gauge sheet metal attached with screws at six inches (152 mm) maximum centers around the perimeter. Lights in doors shall be as set forth in Sections 15.22.140 and 15.22.150. 15.22.92 A single swinging door, the active leaf of a pair of doors, and the bottom leaf of Dutch doors shall be equipped with a deadbolt and a latch. If a key-locking feature is incorporated in the latching mechanism, a dead latch shall be used. The deadbolt and latch may be activated by one lock or by individual locks. Deadbolts shall contain hardened inserts, or the equivalent, so as to repel cutting tool attack. The deadbolt lock or locks shall be key operated from the exterior side of the door and engaged or disengaged from the interior side of the door by a device not requiring a key, tool or excessive force. Exceptions: 1. The latch may be omitted from doors in group B occupancies. 2. In other than residential occupancies, locks may be key-operated or otherwise operated from the inside when not prohibited by Chapter 10 of the California Building Code or other laws and regulations. 3. A swinging door of greater than five feet (1,524 mm) width may be secured as set forth in Section 15.22.110. 4. In residential occupancies, doors not required by Section 310.4 or 1004.1 of the California Building Code may be equipped with security type hardware which requires a key to release from the interior side of the door if the sleeping rooms are protected with a fire warning system as set forth in Section 310.9 of the California Building Code and an automatic sprinkler system as required by Section 903.2.8 of the California Building Code. A straight deadbolt shall have a minimum throw of one inch (25.4 mm), and the embedment shall not be less than five-eighths inch (15.9 mm) into the holding device receiving the projected bolt. A hook-shaped or expanding lug deadbolt shall have a minimum throw of three-fourths-inch (19 mm). All deadbolts of locks which automatically activate two or more deadbolts shall embed at least one-half-inch (12.7 mm), but need not exceed three-fourths-inch (19 mm), into the holding devices receiving the projected bolts. 15.22.93 The inactive leaf of a pair of doors and the upper leaf of Dutch doors shall be equipped with a deadbolt or deadbolts as set forth in Section 6709.2. Exceptions: 1. The bolt or bolts need not be key-operated, but shall not be otherwise activated from the exterior side of the door. 2. The bolt or bolts may be engaged or disengaged automatically with the deadbolt or by another device on the active leaf or lower leaf. 3. Manually operated hardened bolts that are at the top and bottom of the leaf and which embed a minimum of one-half-inch (12.7 mm) into the device receiving the projected bolt may be used when not prohibited by Chapter 10 or other laws and regulations. 15.22.94 Doorstops on wooden jambs for in-swinging doors shall be of one-piece construction with the jamb or joined by a rabbet. 15.22.95 Non-removable pins shall be used in pin type hinges which are accessible from the outside when the door is closed. 15.22.96 Cylinder guards shall be installed on cylinder locks for deadbolts whenever the cylinder projects beyond the outside face of the door or is otherwise accessible to attack tools.

(Ord. No. 1139, § 1, 10-28-2025)

Ask a question about Lancaster law

Corpus searches the Lancaster sections it holds and shows the ones that match, with their citations. Free, no sign-in.