15.36.120 - Existing structures.

Chapter 3 of the Existing Building Code is hereby amended by adding section 324 to read as follows: 324 Repairs to buildings and structures damaged by the occurrence of a natural disaster or fire. 324.1 Purpose. The purpose of this section is to provide a defined level of repair for buildings damaged by a natural disaster in the City of Lancaster when a formal state of emergency has been proclaimed. This section shall also apply when an individual building has been damaged by fire or another disaster. 324.2 General. Required repair levels shall be based on the ratio of the estimated value of the repairs required to restore the structural members to their pre-event condition to the estimated replacement value of the building or structure. 324.3 Structural Repairs. When the damage ratio does not exceed 0.10 (10 percent), buildings and structures, except essential service facilities, shall at a minimum be restored to their pre-event condition. When the damage ratio is greater than 0.10 (10 percent) but less than 0.5 (50 percent), buildings and structures, except essential service facilities, shall have the damaged structural members including all critical ties and connections associated with the damaged structural members, all structural members supported by the damaged member, and all structural members supporting the damaged members repaired and strengthened to bring them into compliance with the force levels and connection requirements of the Building Code. These criteria shall apply to essential service facilities when the damage ratio is less than 0.30 (30 percent). Exception: For buildings with rigid diaphragms where the above-required repair and strengthening increases the rigidity of the resisting members, the entire lateral-force-resisting system of the building shall be investigated. When, in the opinion of the Building Official, an unsafe or adverse condition has been created as a result of the increase in rigidity, the condition shall be corrected. When the damage ratio is greater than 0.5 (50 percent), buildings and structures, except essential service facilities, shall, at a minimum, have the entire building or structure strengthened to comply with the force levels and connection requirements of the Building Code. These criteria shall apply to essential service facilities when the damage ratio is greater or equal to 0.3 (30 percent). 324.4 Nonstructural Repairs to Light Fixtures and Suspended Ceilings. Under all damage ratios, when light fixtures and the suspension system of suspended ceilings are damaged, the damaged light fixtures and ceiling suspension systems shall be repaired to fully comply with the requirements of this code. In buildings and structures where suspended ceiling systems are present, undamaged light fixtures and ceiling suspension systems shall have the additional support and bracing, provided that is required in this code.

(Ord. No. 1139, § 1, 10-28-2025)

Ask a question about Lancaster law

Corpus searches the Lancaster sections it holds and shows the ones that match, with their citations. Free, no sign-in.