For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17.08.100 — Parking and Loading

Lancaster Municipal Code, City of Lancaster, California (Supp. No. 4-26: codified through Ordinance No. 1154, enacted September 8, 2026) · Lancaster Municipal Code § 17.08.100

Corpus is an independent public-information project, not the official City of Lancaster website. Stable reference: corpuslaw.us/code/22dbe6db-1f6f-4089-9289-a574a02a05af

17.08.100 - Parking and Loading.

The automobile parking facilities required by this section shall be provided and permanently maintained unless and until a substitute has been provided which is in full compliance with the provisions of this title. A. General conditions. All buildings shall have permanently maintained off-street parking and shall apply as follows: 1. No structure or use shall be permitted or constructed unless off-street parking spaces are provided and maintained in accordance with the provisions of this section; 2. When a building is enlarged the required amount of parking spaces shall be provided for that enlargement portion, in accordance with the provisions of this section; 3. When there is an increase in the number of bedrooms (to more than one); or 4. When there is an increase in the number of dwelling units. B. Fractions. Fractional space requirements for a parking space shall be rounded up to the next whole space. C. Minimum Number of Required Parking Spaces. Except as necessary to comply with requirements to provide electric vehicle supply equipment installed parking spaces or parking spaces that are accessible to persons with disabilities, the following minimum parking standards apply. 1. For sites located within one-half mile of a major transit stop as defined in Section 21155 of the Public Resources Code, no parking is required, except: a. Event centers shall provide parking for employees and other workers. b. Development projects where any portion is designated for use as a hotel, motel, bed and breakfast inn, or other transient lodging (except where a portion of a housing development project is designated for use as a residential hotel, as defined in Section 50519 of the Health and Safety Code) shall provide parking in accordance with the minimum parking requirements of subsection C.2 (see "Parking Requirements by Use" Table). c. Development projects for which, within 30 days of the receipt of a completed application, the city finds that based on a preponderance of the evidence in the record that not imposing or enforcing minimum automobile parking requirements on the development would have a substantially negative impact on any of the following: 1) The city's ability to meet its share of the regional housing need in accordance with Section 65584 for low- and very low-income households. 2) The city's ability to meet any special housing needs for the elderly or persons with disabilities identified in the analysis required pursuant to paragraph (7) of subdivision (a) of Section 65583. 3) Existing residential or commercial parking within one-half mile of the housing development project. d. Subsection (c) above shall not apply for the following projects: 1) Housing development projects that dedicate a minimum of 20% of the total number of housing units to very low, low-, or moderate-income households, students, the elderly, or persons with disabilities. 2) Housing development projects that contain fewer than 20 housing units. 3) Housing development projects subject to parking reductions based on the provisions of any other applicable state law. 2. For sites located more than one-half mile from a major transit stop as defined in Section 21155 of the Public Resources Code, the following number of parking spaces shall be the minimum provided for each new use: Parking Requirements by Use Use | Number of Required Spaces 1. Single-family house | 2 parking spaces within an enclosed garage a. Accessory dwelling unit/Junior ADU | See Chapter 17.41, Article I 2. Duplex/triplex/four-plex | 2 parking spaces within an enclosed garage for each unit a. Two-unit project | See Chapter 17.41, Article III 3. Apartments, 5 or more units a. Studio/loft and one bedroom | 1 and ½ covered spaces for each unit b. Two or more bedrooms | 1 and ½ covered and ½ uncovered for each unit c. Guest parking | 1 uncovered space for every 4 units 4. Condominiums | 2 parking spaces within an enclosed garage for each unit and 1 guest space for every 4 units 5. Condominiums, mid-rise (3+ stories) a. Studio/loft and one bedroom | 1 and ½ covered spaces for each unit b. Two or more bedrooms | 1 and ½ covered and ½ uncovered for each unit c. Guest parking | 1 uncovered space for every 4 units 6. Boarding or rooming house, hostel, fraternity or sorority house | 1 uncovered space for each guest room and 2 spaces within an enclosed garage for resident manager 7.Special needs housing including senior apartments/condominiums, housing facilities for persons with disabilities, supportive housing, transitional housing, and employee housing in compliance with the Employee Housing Act | 1 covered parking space for each unit and 1 guest space for every 4 units 8. Senior residential care facility | 1 space for every 3 beds and 1 space for each resident employee 9. Churches | 1 space for each 5 fixed seats or for each 45 square feet of seating area within the main auditorium; 24 inches of bench shall be considered a fixed seat 10. Daycare center (nursery/preschool) | 5 spaces per 100 students 11. Elementary and middle school | 15 spaces per 100 students 12. High school | 26 spaces per 100 students 13. Colleges/universities | 33 spaces per 100 students, plus one space per bed in dormitories Notes: 1. An uncovered parking space shall not include the driveway area for a garage. 2. Parking lots or areas for 10 or more contiguous uncovered vehicle parking spaces shall comply with the requirements of subsection 17.08.090.D (Parking design and performance standards) for design and development of landscaping and surface parking area. 3. Parking for uses subject to conditional use permit shall meet the requirements specified in the permit or as otherwise provided in this title. 4. Requirements for uses not specifically listed herein shall be determined by the director based upon the requirements for comparable uses and upon the particular characteristics of the use. 5. The number of parking spaces required may be reduced, at the discretion of the director, if the builder can sufficiently demonstrate, through research and analysis that the development warrants fewer parking than is required. Such parking reductions may be granted if the development is located near public transit or if the builder pays in-lieu parking fees for future public parking, transportation, or pedestrian and bicycle trail improvements. 6. For multi-family uses, a private owner retains the right to assign parking spaces for tenants and visitors, provided there are enough parking spaces per city code. D. Accessible Parking. Housing providers shall adhere to the accessible parking regulations of the American Disabilities Act "ADA," Part 20 of the United States Code of Federal Regulations, and the state building code. In accordance to these regulations, housing providers shall establish the following number of accessible parking spaces for multiple-family developments: Total Number of Parking Spaces in Lot or Garage | Minimum Required Number of Accessible Spaces 1—25 | 1 26—50 | 2 51—75 | 3 76—100 | 4 101—150 | 5 151—200 | 6 201—300 | 7 301—400 | 8 401—500 | 9 501—1,000 | 2% of total 1,001 and over | 20 plus one for each 100, or fraction over 1,001 E. Parking Design Standards. The following design and development standards shall be met for development in all residential zones. 1. Location of Parking Facilities. a. Required off-street parking shall be located on the same parcel as the uses served, unless it can be sufficiently demonstrated that parking from another parcel can adequately serve the project, with a recorded parking agreement between the parcels. b. Parking facilities other than driveways shall not be located in a required front or street side setback. 2. Access to Parking Facilities and Parking Spaces. a. Access to Parking Lots. Parking facilities shall be designed to prevent vehicle access at any point other than at designated driveway entrances. b. Access to Individual Unit Garages. Garages shall be accessed via a minimum 20-foot-length driveway. Garage driveway width shall be minimum 20-foot wide, except for access into tandem garages, or rear-located garages (not alley access), in which the driveway width shall be minimum 12-foot, and shall widen or taper as necessary to allow for adequate vehicle access. c. Internal Maneuvering and Queuing. Parking facilities shall provide suitable maneuvering room so that vehicles enter the street in a forward direction, except for lots with 4 or fewer residential units. 3. Parking Space and Facility Dimensions. a. Individual Unit Garages. Parking spaces within garages shall have minimum dimensions of 10 feet in width and 20 feet in length, clear of any obstructions b. Carports. Parking spaces within carports shall have minimum dimensions of 9½ feet in width and 19 feet in length, clear of any obstructions. c. All Other Parking Spaces. Minimum parking space dimensions shall be as follows, except as shown in the following table and figure. 1) Standard parking spaces shall have a minimum dimension of 9 feet in width by 18 feet in length, except for spaces provided at either a 45 or 30 degree layout, in which the spaces shall have a minimum dimension of 8½ feet in width by 18 feet in length. 2) Up to 35% of the spaces in a parking lot may be compact spaces, with minimum dimensions of 8 feet in width by 16 feet in length. For multi-residential uses, this shall only apply to guest parking spaces. 3) Parallel parking spaces shall be 8 feet by 22 feet, except that spaces that are unencumbered at one end may be reduced to 8 feet by 20 feet. 4) The width of a parking space shall be increased by one foot if either side of the space is adjacent to a wall, fence, support column or other structure, except where the obstruction is limited to the front or rear one-third of the parking space. [image omitted; see the official code] [image omitted; see the official code] 4. Curbing. Continuous concrete curbing at least 6 inches high and 6 inches wide shall be provided along the edges of parking spaces adjacent to fences, walls, sidewalks, other structures, and landscaping. a. Alternative barrier designs may be approved by the director. b. Parking spaces adjacent along their length to landscaped areas or other similar surfaces shall incorporate a paved extension of the curb measuring 12 inches (for a total of 18 inches) to provide a place to stand while exiting and entering vehicles. c. Although discouraged, wheel stops may be installed as determined by the director, in the uncommon circumstance where there is no curbing or landscaping that buffer parking spaces from a fence or other structures. The wheel stop shall be located in a manner that prevents a vehicle from colliding into a fence, or other structures. d. Curb design and installation shall comply with national pollution discharge elimination system (NPDES) standards where applicable. 5. Directional Arrows and Signs (except single-family detached): a. Parking spaces, aisles, approach lanes, and maneuvering areas shall be clearly marked with directional arrows and lines to ensure the safe and efficient flow of vehicles. b. The director may require the installation of traffic signs in addition to directional arrows to ensure the safe and efficient flow of vehicles in a parking facility. 6. Access to Public Right-of-Way. Each vehicular passage of any parking or loading facility to or across a public right-of-way shall comply with the following requirements: a. No such curb cut may exceed 24 feet in width for single-family residential uses, or 35 feet for multi-family residential uses, unless as approved by a director's review. Curb cut is defined as the flat bottom dimension for the driveway, excluding wings. b. Wherever feasible, curb cuts serving adjacent uses shall be combined to minimize the number of entrances onto arterial and collector streets. c. Only one curb cut may be installed for any parking or loading facility, provided that additional curb cuts may be allowed if the city engineer determines that each such additional curb cut is necessary for the efficient operation of the facility and will not significantly affect capacity and traffic safety. d. Curb cuts for any circular driveway or multiple driveways on the same lot must meet the following requirements: 1) The curb cuts of circular or multiple driveways must be at least 20 feet apart. 2) The combined width of the curb cuts shall not exceed 40% of the lot frontage. e. Any curb cut on a corner shall be located at the farthest point on the lot from the curb return. 7. Striping and Identification (except single-family residential). Parking spaces shall be clearly outlined with 4-inch wide lines painted on the surface of the parking facility. Circulation aisles, approach lanes, and turning areas shall be clearly marked with directional arrows and lines to ensure safe traffic movement. Double-striping outlining of parking spaces is also permitted, using the mid-point of the double-striped area as the measurement of the parking space width. 8. Grade of Parking Facilities. Parking facilities should not exceed a grade of 5%. 9. Parking Lots as a Transitional Use. Parking lots may be permitted in the residential zones as a transitional use, provided: a. In the RR and R zones: 1) The area used for parking adjoins or is separated only by an alley from property in a multiple-family, commercial, or industrial zone; and 2) Parking shall be limited to an area within 100 feet from the boundary of the qualifying multiple-family, mixed use, commercial or industrial zone. b. In the MDR and HDR zones: 1) The area used for parking adjoins or is separated only by an alley from property in a commercial or industrial zone; and 2) Parking shall be limited to an area within 100 feet from the boundary of the qualifying multiple-family, mixed use, commercial or industrial zone. 3) An area developed with parking shall have direct vehicular access to an improved public street, highway, alley, or to the qualifying multiple-family, mixed use, commercial or industrial zone.

(Ord. No. 989, § 1, 4-9-2013; Ord. No. 1106, § 4(Exh. A), 10-10-2023)

Ask a question about Lancaster law

Corpus searches the Lancaster sections it holds and shows the ones that match, with their citations. Free, no sign-in.