17.08.310 - Vertical-axis Wind Turbine Systems (VAWTS).

A. Purpose and Intent. It is the purpose and intent of this section to promote the safe, effective and efficient construction and use of VAWTS on residential lots within the city limits of the city. These regulations are intended to assure that VAWTS are designed and located in a manner that minimizes visual, noise, and safety impacts on the surrounding community. Commercial wind turbines in residential zones are subject to a conditional use permit. B. Applicability. These specific standards are applicable for all vertical axis wind turbine system in residential zones allowed subject to approval of a director's review in accordance with Article VI of Chapter 17.32. C. Definitions. The following are definitions of specialized terms and phrases used in this section. Definitions of general terms and phrases are located in Section 17.04.240 (definitions). "Director" means the planning director of the city. "FAA" means Federal Aviation Administration. "Guy wires" means wires or cables used in tension to support a tower. "Tower" means the portion of the VAWTS upon which the turbine is mounted. "Tower height" means the height above grade of the fixed portion of the tower measured from the ground to the top of the tower, excluding the VAWTS, blades and wind-measuring devices. "USGS" means the United States Geological Survey. "Vertical axis wind turbine system" ("VAWTS") means a small scale, non-commercial vertical axis wind turbine system, designed with a vertical axis, suitable for residential zones consisting of a wind turbine, tower, blades, associated controls and conversion electronics, which has a rated capacity that does not exceed the allowable rated capacity under the emerging renewables fund of the renewables investment plan administered by the state energy commission and which will be used primarily to reduce on-site consumption of utility power by converting mechanical energy into electricity. For the purposes of this section, "wind turbine" shall mean the same as VAWTS. D. Restriction on Use of Electricity Generated by VAWTS. A VAWTS shall be used exclusively to supply electrical power for on-site consumption. Electrical power generated by the VAWTS exceeding on-site consumption may be used by the utility company in exchange for a reduction in the cost of electrical power supplied by that company to the parcel for on-site use, as long as no net revenue is produced by such excess electrical power. VAWTS, as allowed pursuant to this section shall not be used for commercial production or profit. E. Type of Device. Vertical axis wind turbines system (VAWTS) shall meet the following guidelines. All other noncommercial and commercial wind energy conversions system shall meet the requirements outlined in article XI, wind energy conversion systems and shall be subject to a conditional use permit. F. Property Development Regulations. A VAWTS shall be subject to all applicable regulations of the residential zone in which it is proposed, except that the following standards shall take precedence over the regulations of the residential zones to the extent that they differ. The following shall be deemed to be conditions of approval of every VAWTS unless specifically modified under the director's review and approval process. 1. No part of a VAWTS shall be located within or over drainage, utility, or any other established easements. Each VAWTS shall be setback from the nearest above-ground public communication or electrical line by a distance which is equivalent to the height of the VAWTS. 2. Blade Clearance. No part of a VAWTS blade shall extend within 15 feet of the ground, trees, or any other structure. 3. Only one VAWTS shall be allowed per residence. 4. Devices mounted on a building may require strengthening of the existing structure to bear the additional weight and stress created by the VAWTS for which a building permit shall be obtained. G. Yard Requirements. The following shall apply for building and ground mounted VAWTS in all residential zones: 1. VAWTS shall be located behind the primary building outside of the front, side and rear yard setbacks (refer to Section 17.08.060). 2. Tower height shall not exceed the maximum height of the zone in which the VAWTS is located (refer to Section 17.08.060). Diagram showing allowed location of VAWTS [image omitted; see the official code] H. VAWTS Standards. 1. Cage Width. Maximum 78 inches (6½ feet). 2. Cage Height. Maximum 84 inches (7 feet). 3. California Energy Commission Approval. The equipment shall meet the state energy commission standards for approved small wind turbines (VAWTS) [www.consumerenergycenter.org]. 4. Compliance with Aviation Safety Standards. The VAWTS shall comply with all applicable FAA requirements, including any necessary approvals for installations close to airports and other facilities with flight operations in the vicinity such as Fox Field, and Plant 42. 5. Design. A VAWTS must be designed and constructed in accordance with the following: a. Colors. The colors used in the construction materials or finished surface shall be muted and visually compatible with surrounding development. b. Lighting. If required by FAA requirements, all required lights shall be shielded from adjacent properties, and no other lights shall be placed upon the tower. c. Noise. Noise from a VAWTS shall conform with normally acceptable noise standards of 65 dBA at property line. d. Visual Effects. Any VAWTS that is placed within the viewshed of a designated scenic highway or vista shall be assessed for its visual effects, and appropriate conditions relating to setting, buffers, and design of the facility. e. Climbing Apparata. All climbing apparatus for ground-mounted VAWTS must be located at least 15 feet above the ground, and the structure must be designed to prevent climbing within the first 15 feet. f. Automatic Overspeed Controls. VAWTS shall be equipped with manual and automatic overspeed controls to limit the blade rotation speed to within the design limits of the VAWTS. g. Access Doors. If a VAWTS is equipped with access doors, all access doors shall be lockable. 6. Grid Interconnection. The renewable energy must be permanently interconnected to the electrical distribution grid of the utility serving the customer's electrical load. The VAWTS shall interconnect to the electricity distribution system and must comply with applicable electrical codes and utility interconnection requirements. 7. Maintenance. VAWTS shall be maintained in an operational condition that poses no potential safety hazards. 8. Removal. Within 6 months after the VAWTS has ceased to operate the permittee shall remove the VAWTS, clear the site of all equipment, and restore the site as nearly as practicable to its condition prior to the installation of the VAWTS. Failure to remove such VAWTS shall constitute as a public nuisance. I. The planning director can require additional design criteria or other information as deemed necessary to integrate the proposed VAWTS with the surrounding area.

(Ord. No. 989, § 1, 4-9-2013)

Ask a question about Lancaster law

Corpus searches the Lancaster sections it holds and shows the ones that match, with their citations. Free, no sign-in.