17.10.060 - Development and design regulations.
A. Lot Dimensions. The following minimum lot dimensions shall apply to all lots in the MU-N, MU-C and MU-E zones created after the adoption of this section, except those lots created within the boundaries of an approved shopping center or mixed use development to accommodate individual tenants. (Those lots which were legally created, prior to the adoption of this section, in compliance with ordinances in effect at the time of their creation need not comply unless involved in a new subdivision or change in lot configuration other than a lot line adjustment as provided in Title 16 of this code.) See Section 17.40.070, 17.40.080, 17.40.090.A or 17.40.090.B in the event public use or required street dedication would reduce the net lot area, lot width, or lot depth of an existing lot to less than the required minimum. Development Type | Minimum Lot Size | Minimum Width | Minimum Depth Detached single-family unit Lots with front driveway access | 4,750 sq. ft. | 50 ft. | 85 ft. Lots with alley access | 3,500 sq. ft. | 40 ft. | 75 ft. Multi-family, commercial/office, and mixed use development Lots with front driveway access | 10,000 sq. ft.* | 80 ft. | 160 ft. Lots with alley access | 6,000 sq. ft.* | 60 ft. | 75 ft. * Minimum lot size for multi-family and mixed use development shall be increased by 1,600 sf per unit for each additional dwelling unit over 2 | *1,600 sq. ft. per unit | N/A | N/A Light Industrial development | 15,000 sq. ft. | 80 ft. | 160 ft. B. Minimum Setbacks and Street Frontage Standards. 1. Minimum setbacks and street frontage standards are established below. Location | Minimum Setback | Street Frontage Maximum Setback | Minimum % of Frontage Street Frontage Standard (see subsection 17.10.060.B.2) • Detached single family dwelling and duplexes (not permitted to front onto arterial streets) | 10 ft. | 18 ft. | 65% • Multi-family building and mixed use buildings with ground floor residential • 3 to 15 dwelling units | 12 ft. | 18 ft. | 65% • 16 or more dwelling units | 12 ft. | 20 ft. | 60% • Commercial/office buildings and mixed use buildings with nonresidential uses on the ground floor • major arterial streets | 10 ft. | 18 ft. | 60% • all other street lot lines | 0 ft. | 12 ft. • Light-industrial building | 12 ft. | 20 ft. | 60% Side Yards • Single family unit with minimum 10 ft. building separation | 0 ft. | N/A | N/A • Multi-family • First Floor | 10 ft. | N/A | N/A • Second and Third Floor | 15 ft. • All other uses • First floor | 5 ft. | N/A | N/A > • Second floor and above | 10 ft. Rear Yards | 10 ft. | N/A | N/A 2. Street Frontage Standards. The street frontage standards apply to the street-facing lot line where pedestrian or vehicular access is available to the site from that frontage. a. New buildings, or additions to existing buildings, shall be designed and located so that at least the specified minimum percentage of frontage is occupied by buildings that are located no further from the street frontage(s) than the specified maximum setback. b. For those buildings located to comply with the street frontage standards, vehicular driveways and parking areas shall not be located between the facade of a building and the back of the public sidewalk. In areas of the site where buildings are not located required to be located in compliance with the street frontage standard, a minimum landscaped area of 10 feet in width shall be provided from the back of the sidewalk to any parking area. Such width may be reduced by the approving authority where a parkway design is used to separate the sidewalk from the street curb. Landscaping installation and maintenance shall be in accordance with the requirements of Chapter 8.50. c. Use limitations on development sites with frontage on a major or secondary arterial street. (1) Within the MU-C zone, at least 50% of the ground floor that fronts on the arterial must be committed to one or more of the following use categories: Retail/Service, Lodging, or Public/Semi-Public (see Use Matrix). (2) Within the MU-E zone, at least 50% of the ground floor that fronts on the arterial must be committed to one or more of the following use categories: Office/Professional/Light Industrial, Lodging, or Public/Semi-Public (see Use Matrix). (3) For a building's ground floor to be considered committed to a use, the ground floor interior spaces that front on the arterial street must be constructed to building code standards for the use or planned for the use upon completion. d. Exceptions to Maximum Setback Standards. Exceptions to the maximum setbacks established in subsection may be granted by the approval authority in the following circumstances: (1) On a corner or multiple frontage development sites, an exception may be granted to reduce the percent of frontage required on one of the frontages where another frontage exceeds the minimum requirement and the overall intent street frontage standard is met. (2) Where people-oriented activity areas, such as outdoor dining locations, are provided at the between the building and the street and designed in such a way as to meet the intent street frontage standard an exception may be granted. 3. Projections and Encroachments. The following encroachments are permitted within the area established by street frontage standard. a. Residential porches may encroachment up to 6 feet into front setback. Additional projections may be permitted into yards subject to Section 17.08.160. b. Dining patios associated with restaurants/cafe/bakery/deli uses may encroach into the front setback up to front property line. C. Building Height. 1. Except as specified in Section 17.10.060.C.2, the height of buildings or structures shall be as follows: Maximum Building Height Detached single family dwelling | 2 stories Multi-family building • 1 to 15 dwelling units | 3 stories • 16 or more dwelling units | 4 stories* Commercial/office building | 50 feet Mixed-use building | 50 feet Light-industrial building | 50 feet * Up to 5 stories permitted for buildings located on a major arterial. 2. Exceptions to building height. a. The exceptions to height regulations in Section 17.40.630 shall apply. b. Solar collectors may exceed the height limit when mounted on the roof of a legal, conforming building. The right to exceed the height limit shall be exercised only in the event that: there is no other practical means or location for achieving an efficient placement on the building or site in question; such collectors may exceed the height limit only to the extent necessary to achieve efficient placement; in no case shall such solar collectors (or related equipment) encroach more than 5 feet beyond the limit. Also, the placement of a solar collector shall not shade or otherwise diminish the efficiency of existing solar collectors on neighboring property or preclude such property from sufficient solar access to successfully operate a solar energy system sufficient to serve the needs of the business or occupants. D. Parking. The automobile parking facilities required by this section shall be provided and permanently maintained as such unless and until a substitute has been provided which is in full compliance with the provisions of this title. The following parking requirements shall be complied with in the mixed use zones: 1. Residential uses (including when a part of a mixed use development) shall be subject to the parking requirements in Section 17.08.100 (Parking and loading in Residential zones) as follows: a. Detached single family dwellings shall be subject to the standards in Section 17.08.100 applicable to a single-family house. b. Multi-family dwelling units with individual enclosed garages serving the unit shall be subject to the standards in Section 17.08.100 applicable to a duplex/triplex/four-plex unit. c. Multi-family dwelling units where parking is provided in one or more shared parking structures, shall be subject to the standards in Section 17.08.100 that are applicable to apartments with 5 or more units apply. d. In addition, following standards apply: (1) Enclosed garages serving individual units shall meet the following standards: • The garage door shall be a minimum of 40 feet from the front property line. Detached garage may abut rear property line unless access is from an alley in which case a minimum 26 feet from back of alley is required for sufficient back-up clearance. • A covered breezeway, connecting the primary residence to a detached garage, is permitted, provided it is not enclosed. • Garages shall include a 100 cu. sq. ft. shelving area for storage. This storage area is intended to encourage residents to use garages for vehicle parking. • Maximum driveway width: 12 feet for a driveway providing access to one garage or 26 feet total for driveways providing access to more than one garage. Driveways providing access to one garage shall be separated from other driveways by a minimum buffer of 4 feet of landscaping. (2) On sites with 4 or more dwelling units, one uncovered off-street guest parking space is required for every 4 dwelling unit. 2. Nonresidential uses (including when a part of a mixed use development) shall be subject to the parking requirements in Section 17.12.220 and Section 17.16.210 (Off-street parking standards in commercial zone and industrial zone) that are applicable to the use type. In addition, the following standards apply: a. On-site parking shall be located a minimum 40 feet from the front property line for light industrial buildings; on-site parking for all other nonresidential uses shall be located a minimum of 36 feet from the front property line. b. Reciprocal driveway access between multiple parcels, connecting adjacent parking lots, is required where feasible. c. Truck loading docks shall be a minimum of 40 feet from the front property line and screened from street view. 3. Mixed-Use Building. For residential and commercial/office uses, the number of parking spaces shall be in accordance with the requirements listed by use in this section. Parking spaces between residential and commercial/office uses shall not be shared and be specifically identified on site as private residence parking versus public customer parking. 4. Parking requirements may be reduced, at the discretion of the director, if the builder can sufficiently demonstrate, through research and analysis, that the development warrants fewer parking than is required. E. Open Space and Landscaping. The landscaping and open space required by this section shall be provided and permanently maintained as such unless and until a substitute has been provided which is in full compliance with the provisions of this title. The following landscaping and open space requirements shall be complied with in the mixed use zones: Development Type | Minimum Required Open Space | Minimum Required Landscaping Single family dwellings | N/A | On corner lots, the street side yard facing a corner shall have 10' landscaping. Multi-family developments | 10% of lot area • Min. dimensions for shared open space: 20 ft. width and depth for 1 to 15 units • 50 ft. width and depth for 16+ units | 8% of lot area Commercial/office and mixed use development | 10% of lot area (may include dining patio encroachment) Min. dimensions: N/A | 8% of lot area Light-industrial building | N/A | 8% of lot area 1. Drought-resistant varieties of plants shall be used in accordance with Title 8, Chapter 8.50, Landscaping Installation and Maintenance; Title 8, Chapter 8.30, Residential Landscaping Installation and Maintenance; and Title 15, Chapter 15.48, Specifications for Landscape Development of the Lancaster Municipal Code, as applicable. 2. Landscaped areas shall be irrigated by an automatic system with separate stations for each hydrozone. The irrigation system shall be designed and equipped to incorporate water conservation techniques, such as drip systems, moisture sensors and anti-drain valves. Sprinkler systems shall be designed to prevent water from falling onto impervious surfaces. The system shall comply with Title 8, Chapter 8.50, landscaping installation and maintenance; and Title 8, Chapter 8.30, residential landscaping installation and maintenance of this code, if applicable. 3. All areas which are not utilized for buildings, sidewalks, vehicle access, or parking, shall be permanently landscaped and maintained. 4. All landscaped planters for interior parking areas shall be completely bordered by a 6-inch concrete curb to prevent runoff. 5. Required Landscaping. The following basic standards shall be observed: a. All interior areas of parking lots shall be landscaped with a minimum of one shade tree plus one shade tree for each 4 parking spaces along with other required plant materials. b. The minimum required landscaping for parking lots shall be the percentage shown below of the total area used for vehicle ingress, egress, circulation and parking. Only landscaped areas exclusive of curbs shall qualify toward meeting this requirement and no landscaped area with a dimension of less than 2 feet shall be credited toward meeting the landscape requirement. Parking Lot Size | Minimum Percentage of Parking Lot Landscaping Required 1—4,999 square feet | 5% 5,000—19,999 square feet | 6% 20,000 or more square feet | 7% c. Where off-street parking areas abut local or collector public streets, such areas shall be separated from an abutting street by a continuous landscaped planter which extends parallel to the street frontage of the parking area. The planter shall be a minimum of 10 feet in width exclusive of perimeter curbs. Up to one-half of the area of this required landscape planter may be counted toward fulfilling the requirements of the required landscaping for lots under 20,000 square feet. 6. All landscaped areas shall be continuously and properly maintained in good condition. 7. At least 25% of all trees installed shall be from a 24 inch box, and no tree shall be less than 15 gallon size. At least 50% of all shrubs shall be of 5-gallon size, and no shrub shall be less than one-gallon size. Ground covers shall be planted at no further apart than 6 inches on center. F. Fences, Walls, and Screening. Fences, walls and screening for residential development (excluding residential development when a part of a mixed use development) shall comply with the standards in Section 17.08.130. G. Building Design Requirements. 1. Primary Entries. All buildings located entirely or partially within the maximum setback shall have a primary entrance directly facing the street frontage and provide direct pedestrian access to the primary entrance from the adjacent street frontage. A primary entrance may be located on the side of a building not directly facing a street frontage provided that the entrance is clearly visible to people from the adjacent street, direct public access is provided, and the building facade directly facing the street has sufficient fenestration and other design elements and treatment to create a visible connection with that street frontage. If necessary, dual building entrances shall be provided; one facing the street frontage, connected to the sidewalk; another facing the parking area. Except for entrances into individual dwellings, primary entrances shall be designed to provide public access to the building. 2. Windows. The street facing facades of buildings located entirely or partially within the maximum setback should be designed to include windows as a significant percentage of the facade. Blank, windowless facades are not permitted. Windows in nonresidential buildings should be designed to allow views into working area; however, display windows can be provided as an alternative. Residential windows should also consider privacy. Windows of a facade along a zero-lot line facing a neighboring side yard shall be small and have a high sill height, typically 6 feet above the finished floor, or have translucent glazing. 3. Commercial and Mixed Use Buildings. a. Mixed-use buildings are designed to accommodate a combination of both commercial/office and residential uses. "Vertical" mixed-use developments are designed with retail, service, and/or office uses on the ground floor, with upper floors used for those uses or for residential dwelling units. "Horizontal" mixed-use developments have retail, service and/or office uses on the same project site as residential uses, but not within the same building. For "vertical" mixed use developments, residential uses shall be located above non-residential uses. For "horizontal" mixed use developments, non-residential uses shall be oriented closer to the street than residential uses. b. Design of ground floor building facades facing a street shall provide the appearance of a storefront. Design elements may include arcades, patios, awnings, and overhangs as appropriate to enhance appearance and use of the space. c. Uses and facilities such as shared parking and open space shall be connected by pedestrian pathways. 4. Trash enclosure shall meet the following requirements: a. Trash enclosures shall be located or screened so that they are not visible from primary entrances drive or streets; b. Trash enclosure shall be a minimum of 165 square feet; c. Source separation of recyclable materials shall be accommodated in accordance with state requirements; d. Trash enclosures shall be constructed with a non-combustible, overhanging, trellis or roof cover; and e. Trash enclosures shall be separated from adjacent parking by at least a 6-foot wide planter. H. Signs. A person shall not use, install, or construct any sign in the MU-N, MU-C or MU-E zone except as specifically permitted in this section. 1. Signs for commercial developments shall adhere to the standards in Sections 17.12.140 through 17.12.210 of the zoning code (Commercial zone), as well as the design and performance standards in Section 17.10.070. 2. Signs for residential developments shall adhere to the standards in Sections 17.08.120 of the zoning code (Residential zone), as well as the design and performance standards in Section 17.10.070. 3. Signs for light industrial developments shall adhere to the standards in Sections 17.16.140 through 17.16.200 of the zoning code (industrial zone), as well as the design and performance standards in Section 17.10.070.
(Ord. No. 946, § 1, 7-13-2010; Ord. No. 1106, § 4(Exh. A), 10-10-2023; Ord. No. 1130, § 4(Exh. A), 5-27-2025)
Ask a question about Lancaster law
Corpus searches the Lancaster sections it holds and shows the ones that match, with their citations. Free, no sign-in.