For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17.40.190 — Provisions for flood hazard reduction

Lancaster Municipal Code, City of Lancaster, California (Supp. No. 4-26: codified through Ordinance No. 1154, enacted September 8, 2026) · Lancaster Municipal Code § 17.40.190

Corpus is an independent public-information project, not the official City of Lancaster website. Stable reference: corpuslaw.us/code/f40e2e45-2f45-4e88-a07e-001a8faea95b

17.40.190 - Provisions for flood hazard reduction.

A. Standard of Construction. In all areas of special flood hazards the following standards are required: 1. Anchoring. a. All new construction and substantial improvements shall be adequately anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy. b. All manufactured homes shall meet the anchoring standards of subsection D. of this section. 2. Construction Materials and Methods. a. All new construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage. b. All new construction and substantial improvements shall be constructed using methods and practices that minimize flood damage. c. All new construction and substantial improvements shall be constructed with electrical, heating, ventilation, plumbing and air conditioning equipment and other service facilities that are designed and/or located to prevent water from entering or accumulating within the components during conditions of flooding. d. Require within zones AH or AO that adequate drainage paths around structures on slopes to guide flood waters around and away from proposed structures. 3. Elevation and Floodproofing. a. New construction and substantial improvements shall have the lowest floor, including basement, elevated to or above the base flood elevation. Nonresidential structures may meet the standards in subsection A.3.c. of this section. Upon the completion of the structure, the elevation of the lowest floor, including basement, shall be certified by a registered professional engineer or surveyor, or verified by the community building inspector to be properly elevated. Such certification or verification shall be provided to the floodplain administrator. b. New construction and substantial improvement in zone AO shall have the lowest floor, including basement, elevated above the highest adjacent grade at least as high as the depth number specified in feet on the FIRM, or at least 2 feet if no depth number is specified. Nonresidential structures may meet the standards in subsection A.3.c. of this section. Upon the completion of the structure, the elevation of the lowest floor, including basement, shall be certified by a registered professional engineer or surveyor, or verified by the community building inspector to be properly elevated. Such certification or verification shall be provided to the floodplain administrator. c. Nonresidential construction shall be either elevated to conform with subsection A.3.a. or b. of this section or together with attendant utility and sanitary facilities: 1) Be floodproof so that below the base flood level the structure is watertight with walls substantially impermeable to the passage of water; 2) Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy; and 3) Be certified by a registered professional engineer or architect that the standards of this subsection are satisfied. Such certifications shall be provided to the floodplain administrator. d. Require, for all new construction and substantial improvements, that fully enclosed areas below the lowest floor that are usable solely for parking of vehicles, building access or storage in an area other than a basement and which are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwater. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or meet or exceed the following minimum criteria: 1) Either a minimum of 2 openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided, the bottom of all openings shall be no higher than one foot above grade (openings may be equipped with screens, louvers, valves or other coverings or devices provided that they permit the automatic entry and exit of floodwater); or 2) Be certified to comply with a local flood proofing standard approved by the Federal Insurance Administration of the Federal Emergency Management Agency. e. Manufactured homes shall also meet the standards in subsection D of this section. B. Standards for Utilities. 1. All new and replacement water supply and sanitary sewage systems shall be designed to minimize or eliminate infiltration of floodwaters into the system and discharge from systems into flood waters. 2. On-site waste disposal systems shall be located to avoid impairment to them or contamination from them during flooding. 3. Other utilities are addressed in subsections A.2. and C.4. of this section. C. Standards for Subdivisions. 1. All preliminary subdivision proposals shall identify the flood hazards area and the elevation of the base flood. 2. All subdivision plans will provide the elevation of proposed structure(s) and pad(s). If the site is filled above the base flood elevation, the final first floor and pad elevations shall be certified by a registered professional engineer or surveyor and provided to the floodplain administrator. 3. All subdivision proposals shall be consistent with the need to minimize flood damage. 4. All subdivision proposals shall have public utilities and facilities such as sewer, gas, electrical and water systems located and constructed to minimize flood damage. 5. All subdivisions shall provide adequate drainage to reduce exposure to flood hazards. D. Standards for Manufactured Homes. 1. All manufactured homes that are placed or substantially improved within zones A1—30, AH and AE on the community's Flood Insurance Rate Map on sites (a) outside of a manufactured home park or subdivision; (b) in a new manufactured home park or subdivision; (c) in an expansion to an existing manufactured home park or subdivision; (d) in an existing manufactured home park or subdivision on which a manufactured home has incurred "substantial damage" as the result of a flood should be elevated on a permanent foundation such that the lowest floor of the manufactured home is elevated to or above the base flood elevation and is securely anchored to an adequately anchored foundation system to resist flotation collapse and lateral movement. 2. All manufactured homes to be placed or substantially improved on sites in an existing manufactured home park or subdivision within zones A1—30, AH and AE on the community's Flood Insurance Rate Map that are not subject to the provisions of subsection D.1. of this section will be elevated so that either: a. The lowest floor of the manufactured home is at or above the base flood elevation; or b. The manufactured home chassis is supported by reinforced piers or other foundation elements of at least equivalent strength that are no less than 36 inches in height above grade and be securely anchored to an adequately anchored foundation system to resist flotation, collapse and lateral movement. E. Standards for Recreational Vehicles. All recreational vehicles placed on sites within zones A1—30, AH and AE on the community's Flood Insurance Rate Map will either: 1. Be on the site for fewer than 180 consecutive days; 2. Be fully licensed and ready for highway use (a recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached additions); or 3. Meet the permit requirements of Section 17.40.180 and the elevation and anchoring requirements for manufactured homes in subsection D.1. of this section. F. Floodways. Located within areas of special flood hazard established in Section 17.40.170B are areas designated as floodways. Since the floodway is an extremely hazardous area, due to the velocity of floodwaters which carry debris, potential projectiles and erosion potential, the following provisions apply: 1. Prohibit encroachments, including fill, new construction, substantial improvement, and other new development unless certification by a registered professional engineer or architect is provided demonstrating that encroachments shall not result in any increase in flood levels during the occurrence of the base flood discharge. 2. If subsection F.1. of this section is satisfied, all new construction, substantial improvement, and other proposed new development shall comply with all other applicable flood hazard reduction provisions of this section.

(Prior zoning ord. §§ 705.5—705.5.6)

Ask a question about Lancaster law

Corpus searches the Lancaster sections it holds and shows the ones that match, with their citations. Free, no sign-in.