For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17.40.330 — Processing facilities

Lancaster Municipal Code, City of Lancaster, California (Supp. No. 4-26: codified through Ordinance No. 1154, enacted September 8, 2026) · Lancaster Municipal Code § 17.40.330

Corpus is an independent public-information project, not the official City of Lancaster website. Stable reference: corpuslaw.us/code/0240a99e-ca3b-463b-9932-d2fa97afb615

17.40.330 - Processing facilities.

Light (45,000 square feet or less) and heavy (greater than 45,000 square feet) recycling processing facilities shall comply with the following standards: A. Facility does not abut a property zoned or planned for residential use. B. Processors will operate in a wholly enclosed building except for incidental storage, or: 1. Within a surfaced area enclosed on all sides by a masonry wall not less than 8 feet in height and landscaped on all street frontages; 2. Located at least 150 feet from property zoned or planned for residential use. C. Power-driven processing shall be permitted, provided all noise level requirements are met. Light processing facilities are limited to baling, briquetting, crushing, compacting, grinding, shredding and sorting of source-separated recyclable materials and repairing of reusable materials. D. A light processing facility shall be no larger than 45,000 square feet and shall have no more than an average of 2 outbound truck shipments of material per day and may not shred, compact or bale ferrous metals other than food and beverage containers. E. A processing facility may accept used motor oil for recycling from the generator in accordance with Section 25250.11 of the California Health and Safety Code. F. Setbacks and landscaping requirements shall be those provided for the zoning district in which the facility is located. G. All exterior storage of material shall be in sturdy containers or enclosures which are covered, secured and maintained in good condition. Storage containers for flammable material shall be constructed of nonflammable material. Oil storage must be in containers approved by the fire and health departments. No storage, excluding truck trailers and overseas containers, will be visible above the height of the fencing. H. Site shall be maintained free of litter and any other undesirable materials, and will be cleaned of loose debris on a daily basis and will be secured from unauthorized entry and removal of materials when attendants are not present. I. Space shall be provided on site for the anticipated peak load of customers to circulate, park and deposit recyclable materials. If the facility is open to the public, space will be provided for a minimum of 10 customers or the peak load, whichever is higher, except where the director determines that allowing overflow traffic is compatible with surrounding businesses and public safety. J. One parking space will be provided for each commercial vehicle operated by the processing center. Parking requirements will otherwise be as mandated by the zone in which the facility is located. K. Noise levels shall not exceed 60 dBA as measured at the property line of residentially zoned or occupied property, or otherwise shall not exceed 70 dBA. L. If the facility is located within 500 feet of property zoned or planned for residential use, it shall not be in operation between 7 p.m. and 7 a.m. The facility will be administered by on-site personnel during the hours the facility is open. M. Any containers provided for after-hours donation of recyclable materials will be at least 100 feet from any property zoned or occupied for residential use; shall be of sturdy, rustproof construction; shall have sufficient capacity to accommodate materials collected; and shall be secure from unauthorized entry or removal of materials. N. Donation areas shall be kept free of litter and any other undesirable material. The containers shall be clearly marked to identify the type of material that may be deposited. Facility shall display a notice stating that no material shall be left outside the recycling containers. O. Sign requirements shall be those provided for the zoning district in which the facility is located. In addition, facility will be clearly marked with the name and phone number of the facility operator and the hours of operation. P. No dust, fumes, smoke, vibration or odor above ambient level may be detectable on neighboring properties. Q. Failure to comply with any standard set forth in this section shall be grounds for the director to order the closure/removal of the processing facility.

(Ord. 711 § 46, 1995; prior zoning ord. § 710.040)

Ask a question about Lancaster law

Corpus searches the Lancaster sections it holds and shows the ones that match, with their citations. Free, no sign-in.