For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17.40.380 — Contents of applications

Lancaster Municipal Code, City of Lancaster, California (Supp. No. 4-26: codified through Ordinance No. 1154, enacted September 8, 2026) · Lancaster Municipal Code § 17.40.380

Corpus is an independent public-information project, not the official City of Lancaster website. Stable reference: corpuslaw.us/code/124a9f22-e185-47ae-b45c-e3f93cd2b78d

17.40.380 - Contents of applications.

Every application for a hazardous waste facility project shall be filed with the director and accompanied by a deposit in the amount set forth in Section 17.40.440. The application shall include, but not be limited to, the following information: A. Name(s), address(es) and telephone number(s) of the applicant(s); B. Evidence that the applicant is the owner of the premises involved or that the applicant has the written permission of the owner to make such application; C. Complete project narrative, demonstrating the need for siting the proposed hazardous waste facility in the specific location identified; D. A project analysis, plot plan, and development plan drawn to scale in sufficient detail to clearly illustrate the following: 1. Physical dimensions of the property and structures, both existing and proposed, 2. Site plan, indicating the initial project proposal and the ultimate land use layout and utilization of property, 3. Location of existing and proposed structures, 4. Setbacks and landscaping, 5. Parking and circulation, 6. Ingress and egress, 7. Drainage patterns, 8. Storage and processing areas, 9. The distance to the nearest residences, to properties designated in the general plan for residential use, to proposed or presently zoned residential areas, and to immobile populations, 10. The distance from the project property line to the nearest adjacent structures, and a description and location of such structures, 11. Topographic description of the property and surrounding area within 2,000 feet of the boundary of the lot or lots on which the proposed facility will be located, 12. Proximity of site to the 100-year floodplain boundary as established by FIRM or FEMA, 13. Distance to all ground water supplies, dry washes, and rivers and aquifers, 14. Proximity to pumping water wells or well fields, whether operational or not, 15. Existing and proposed utilities which service or will be required to service the facility; E. An analysis of visual, noise and any olfactory impacts associated with the project and recommended mitigation measures; F. Identification of all wastewater, treated and untreated, generated by the proposed facility, and the method and place of final discharge; G. An analysis of all anticipated air quality impacts associated with the project and proposed mitigation measures to ensure no degradation of air quality occurs in the area; H. Identification of any rare or endangered species of plant or animals within the project site and surrounding area and recommended impact mitigation measures; I. Identification of the amounts (in tons), sources and types of hazardous wastes to be treated, stored or disposed of at the proposed facility, the ultimate disposition of the wastes, and anticipated life of the facility. This information shall be based on an actual survey of the industries to be served by the facility and thereby be representative of the wastes that will be processed at the facility; J. A risk assessment, including health and environmental risks, which analyzes in detail all possibilities and probabilities of accidents or spills involving hazardous materials or wastes to be used or stored at the site, transportation-related accidents from the point of origin to the facility, and other probabilities requested by either the director, the planning commission or the city council. Such analyses shall specify mitigation measures to reduce the identified risks. The risk assessment shall also identify the most probable routes for transporting hazardous waste to the facility, and identify provisions for automatic facility shutdown and resumption of facility operations in the event of adverse meteorological conditions, fire, flood, earthquake or other geologic or natural phenomena. The risk assessment conducted shall include information required under the Los Angeles County hazardous waste management plan and the standards for the use analysis shall be based on standards generally applied on a statewide and regional basis, by the U.S. Environmental Protection Agency, State Department of Health Services, and South Coast Air Quality Management District; K. The monitoring program required by Section 17.40.400. The monitoring program shall also include any monitoring requirements imposed by other permitting agencies including but not limited to, the South Coast Air Quality Management District (SCAQMD), Lahontan Regional Water Quality Control Board and the State Department of Health Services; L. A water consumption report for the project and proposed mitigation measures for water conservation to the city and to the local water purveyor; M. An emergency response plan as approved by the emergency preparedness coordinator which contains, at a minimum, the following information: 1. That the proposed plan is consistent with any and all applicable county and regional emergency response plans and all city, county, state and federal regulatory requirements regarding emergency response procedures, 2. Detailed procedures to be employed at the time of emergency for each and every type of chemical substance and emergency, including contingency procedures, 3. Anticipated impacts on local fire, police and medical services, 4. Names, home and business addresses, and home and business telephone numbers of all management personnel at the facility, and a detailed description of uncontrolled release and emergency situation reporting procedures; N. A completed city environmental assessment questionnaire; O. A land use map which depicts land uses within 2,000 feet of the boundary of the lot or lots on which the proposed facility will be located; P. A title report completed within 60 days of the date of facility application submittal; Q. Financial statements for the applicant including proposed means for financing the development of the facility, and anticipated costs and revenues associated with operation of the facility; R. Detailed information regarding how the applicant will meet state pollution liability insurance and state requirements for funding closure and post closure; S. Vicinity map which indicates, at a minimum, proximity of the facility to schools, parks, residences, hospitals, and other immobile populations, community facilities, and to properties designated by the general plan for residential use; T. A seismic and geological evaluation of the site must be conducted by a certified geologist/ seismologist which shall confirm, at a minimum, the following information: 1. The proximity to earthquake fault zones, 2. Whether or not active faults or lineaments which would suggest the presence of faults are located within 2,000 feet of the proposed site, 3. A preliminary geological study of the property and surrounding area including a soils analysis location and description of known aquifers, regardless of the potability of those aquifers, 4. Information as to whether ground subsidence and liquefaction have occurred or whether they may occur at the proposed site; U. Documentation of how the proposed facility will serve the needs of local producers of hazardous waste, including household hazardous waste.

(Prior zoning ord. § 711.050)

Ask a question about Lancaster law

Corpus searches the Lancaster sections it holds and shows the ones that match, with their citations. Free, no sign-in.