§ 17.41.016 — ADU and JADU development standards
Lancaster Municipal Code, City of Lancaster, California (Supp. No. 4-26: codified through Ordinance No. 1154, enacted September 8, 2026) · Lancaster Municipal Code § 17.41.016
Corpus is an independent public-information project, not the official City of Lancaster website. Stable reference: corpuslaw.us/code/1663d949-b3b4-4605-a657-53c838cb77f1
17.41.016 - ADU and JADU development standards.
A. ADUs and JADUs on a Single-Family Lot. ADU and JADU standards for lots in a residential or mixed-use zone with a proposed or existing single-family dwelling shall comply with the following: 1. General Requirements. a. Maximum Number. No more than one JADU and one ADU shall be allowed per legal parcel. b. Minimum Size. The minimum size of an ADU or JADU shall be at least that of an efficiency unit as defined in Section 17958.1 of the Health and Safety Code. c. JADU Requirements. JADUs shall comply with the requirements of Government Code Section 65852.22. 2. Requirements for Interior ADU (Converted Space) on a Single-Family Lot. a. Definition. An interior ADU is either: 1) Within the space of an existing or proposed single-family dwelling; or 2) Within the existing space of an accessory structure, plus up to 150 additional square feet if the expansion is limited to accommodating ingress and egress. b. Access. An interior ADU shall have exterior access that is independent of that for the single-family dwelling; and c. Setbacks. An interior ADU shall have side and rear setbacks sufficient for fire and safety, as dictated by applicable building and fire codes. 3. Requirements for Attached ADU on a Single-Family Lot. a. Definition. An attached ADU is new construction that is attached to the primary structure and is not an interior ADU as defined in subsection A.2.a. b. Maximum Size. An attached ADU shall not exceed 850 square feet for a studio or one-bedroom unit and 1,200 square feet for a unit with 2 or more bedroom. Application of the requirements of this subsection A.3 might further limit the size of the ADU; however, no application A.3.d.1 (front-yard setbacks) or A.3.e (maximum lot coverage) may require the ADU to be less than 850 square feet. c. Maximum Height. An attached ADU shall not exceed 25 feet in height. Notwithstanding the foregoing, ADUs shall not exceed 2 stories. d. Minimum Setbacks. 1) Front-yard setback: 25 feet 2) Side-yard setback: 4 feet 3) Rear-yard setback: 4 feet e. Maximum Lot Coverage. Zone | Maximum Lot Coverage RR-2.5, RR-1, SRR, R-15000, R-10,000 | 40% R-7,000, MDR and HDR | 50% Mixed Use Zones | 60% 4. Requirements for Detached ADU on a Single-Family Lot. a. Definition. A detached ADU is new construction that is detached from the primary structure and is not an interior ADU as defined in subsection A.2.a. b. Maximum Height. A detached ADU shall not exceed 18 feet in height, and up to 2 additional feet in height (for a maximum of 20 feet) if necessary to accommodate a roof pitch on the ADU that is aligned with the roof pitch of the primary dwelling unit. c. Minimum Setbacks. 1) Front-yard setback: 25 feet 2) Side-yard setback: 4 feet 3) Rear-yard setback: 4 feet d. Maximum Lot Coverage. Zone | Maximum Lot Coverage RR-2.5, RR-1, SRR, R-15000, R-10,000 | 40% R-7,000, MDR and HDR | 50% Mixed Use Zones | 60% 5. Interior ADU Combined with New Construction. Where an ADU is created through a combination of conversion of an existing structure (interior ADU) and new construction (either attached ADU or detached ADU), the new construction portion of the project is subject to the development standards applicable to new construction standards for attached ADUs in subsection A.3 or detached ADU in subsection A.4, as applicable. If the interior ADU exceeds the maximum sizes indicated in subsections A.3 and A.4, no additional square footage shall be permitted. B. ADUs on a Multi-Family Lot. ADU standards for lots in a residential or mixed-use zone with existing or proposed multi-family dwellings shall comply with the following: 1. General Requirements. a. Maximum Number. 1) Up to 25% of the number of units in the proposed or existing multi-family dwelling (but no less than one) shall be allowed as interior ADUs created within the space of the existing or proposed multi-family structure; and 2) No more than 2 detached ADUs per lot. b. Minimum Size. The minimum size of an ADU shall be at least that of an efficiency unit as defined in Section 17958.1 of the Health and Safety Code. 2. Requirements for Interior ADU (Converted Space) on a Multi-family Lot. a. Definition. An interior ADU is created from space located within portions of existing or proposed multi-family dwelling structures that are not used as livable space, including but not limited to storage rooms, boiler rooms, passageways, attics, basements, or garages; and b. Standards. An interior ADU shall comply with state building standards for dwellings. 3. Requirements for Detached ADU on a Multi-family Lot. a. Definition. A detached ADU is new construction that is detached from the primary structure and is not an interior ADU as defined in subsection B.2.a. b. Maximum Size. A detached ADU shall not exceed 850 square feet for a studio or one-bedroom unit and 1,200 square feet for a unit with 2 or more bedrooms. Application of the requirements of this subsection B.3 might further limit the size of the ADU; however, no application of the requirements in subsection B.3.d.1 (front-yard setbacks) or B.3.e (maximum lot coverage) may require the ADU to be less than 850 square feet. c. Maximum Height. Eighteen feet, and up to 2 additional feet in height (for a maximum of 20 feet) if necessary to accommodate a roof pitch on the ADU that is aligned with the roof pitch of the primary structure. d. Minimum Setbacks. 1) Front-yard setback: 25 feet 2) Side-yard setback: 4 feet 3) Rear-yard setback: 4 feet e. Maximum Lot Coverage. Zone | Maximum Lot Coverage RR-2.5, RR-1, SRR, R-15000, R-10,000 | 40% R-7,000, MDR and HDR | 50% Mixed Use Zones | 60%
(Ord. No. 1106, § 4(Exh. A), 10-10-2023; Ord. No. 1130, § 4(Exh. A), 5-27-2025)
Ask a question about Lancaster law
Corpus searches the Lancaster sections it holds and shows the ones that match, with their citations. Free, no sign-in.
