For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17.41.078 — Building architecture and form—Residential multi-unit buildings (5 or more units) and mixed use projects

Lancaster Municipal Code, City of Lancaster, California (Supp. No. 4-26: codified through Ordinance No. 1154, enacted September 8, 2026) · Lancaster Municipal Code § 17.41.078

Corpus is an independent public-information project, not the official City of Lancaster website. Stable reference: corpuslaw.us/code/62e8b8f4-fc55-4835-be4b-09439ce9cf3a

17.41.078 - Building architecture and form—Residential multi-unit buildings (5 or more units) and mixed use projects.

A. Purpose. These objective building architecture and form regulations are established to help ensure that new residential multi-unit buildings (5 or more units) and mixed use projects provide long-term value to neighborhoods and districts through high design quality building design and enhanced elevations for residential structures that contribute to an attractive neighborhood streetscape. B. Objective design standards for residential multi-unit buildings (5 or more units) and mixed use projects in all zones. 1. Building facades shall be articulated by variation in massing, roof form, and wall planes. This standard shall be met if: a. At least 25% of the area of a street-facing facade is divided into facade planes that are off-set by at least 2 feet in depth from the rest of the facade. Facade area used to meet the facade articulation standard may be recessed behind, or project out from, the primary facade plane, but projections into street right-of-way do not count toward meeting this standard. b. All street facing facades shall include a minimum of 2 of the architectural features listed below: 1) Recessed entrance(s): 3 to 6 feet deep (relative to building facade). 2) Eaves: overhang of not less than 12 inches. 3) Offset: offset in facade or roof of at least 2 feet that extends for at least 4 feet. 4) Bay window: projects from front elevation by not less one foot; up to a maximum of 2 feet. 5) Balcony: one per dwelling unit facing the street, with a minimum depth of 3 feet. c. Building setbacks and wall alignments shall be varied along facades abutting property zoned Rural Residential and Urban Residential (RR-2.5, RR-1, SRR, R-7,000, R-10,000, or R-15,000 zones). Wall plane variation of at least 2 feet in depth and 5 feet in length shall be provided for relief for every 50 linear feet of building facade. d. Rooflines shall be vertically articulated at a maximum of 50-foot intervals along all street frontages through one of the following techniques: 1) A change in height of a minimum 4 feet; 2) A change in roof pitch, plane, or form; or 3) The inclusion of dormers, gables, parapets, varying cornices, and/or clerestory windows. 2. Multiple colors, materials, textures, and applied finishes shall be used to break up wall massing. This standard shall be met if a minimum of 2 exterior building materials, or a different application of the same material, are used on all facades. Glass for windows shall not be considered one of the 2 materials. Prohibited materials include vinyl and aluminum siding, T-111 plywood siding, and exterior insulation finishing system (EIFS). 3. Distinctive entries, porches, balconies, and window treatment shall be provided on street-facing facades. This standard shall be met, if: a. Buildings adjacent to the street have at least one primary building entry oriented to the street. Direct pedestrian access shall be provided between the public sidewalk and the primary building entries. Buildings that are not adjacent to the street shall have front entries that are oriented toward the common driveway or other common areas, such as paseos, forecourts, common walkways, and useable open space; and b. Residential entries provide transitional spaces between public areas fronting the primary street and entrances. This type of element or equivalent shall be required for each unit or group of units; but no less than one of this type of element shall be provided. Building entrances shall incorporate at least one of the following transitional space entry features: 1) Stoop (at least 4 feet by 4 feet and no higher than 5 feet in height). 2) Porch (at least 6 feet by 8 feet for common entries and at least 5 feet by 8 feet for individual entries). 3) Overhang (if building has a shared lobby) with a recessed depth of at least 3 feet. c. Nonresidential entries shall incorporate at least one of the following entry features: 1) Shopfront - a frontage where the main facade of the building is at or near the right-of-way/property line, with the building entrance at the sidewalk grade. For the purposes of this standard, "near the right-of-way/property line" means within 10 feet of the required maximum setback (or build-to line) applicable to the site frontage. 2) Gallery - a frontage where the main facade of the building is aligned at or close to the right-of-way/property line and the gallery element (an attached cantilevered shed roof or colonnade) overlaps the sidewalk. Galleries shall have a consistent depth along the frontage of at least 10 feet. An encroachment permit is required for any structure in the public right-of-way. 3) Forecourt - a frontage where a portion of the main facade of the building is at or near the right-of-way/property line and a central portion is set back, creating a courtyard. For the purposes of this standard, "near the right-of-way/property line" means within 10 feet of the required maximum setback (or build-to line) applicable to the site frontage. 4) Commercial Terrace - a frontage where a terrace extends along the building's frontage providing public (non-vehicular) circulation, outdoor uses and access to the commercial pace entries. d. At least 20% of the area of each facade that faces a street lot line must consist of windows or main entrance doors. Windows used to meet this standard must allow views from the building to the street. Glass block does not meet this standard. To count toward meeting this standard, a door must be at the main entrance and facing the street property line. e. Additional ground-floor window requirement for mixed use buildings. The following ground-floor window standards apply to the portion of a building with ground-floor commercial uses. For the purposes of this paragraph, ground-floor wall area includes exterior wall area from 2 feet to 10 feet above the finished grade. Required ground-floor windows must be windows in walls or entrances that allow views into working area or display windows (must be at least 24 inches deep set into a wall). The bottom of qualifying windows must be no more than 4 feet above the adjacent exterior grade: 1) Windows must cover at least 40% of the ground floor wall area of the portion of a building that has a ground-floor commercial use when the ground-floor wall is located closer than 5 feet from a street lot line. 2) Windows must cover at least 25% of the ground floor wall area of the portion of building that has a ground-floor commercial use when the ground floor wall is located 5 feet or more from a street lot line. 4. Mechanical equipment located on the ground, such as heating or cooling equipment, pumps, or generators, must be screened from view from the street and any abutting residential zones by walls, fences, or vegetation. Vegetative screening shall consist of an evergreen hedge maintained at least 2 feet wide hedge that will be tall enough at maturity to screen the equipment. Mechanical equipment placed on roofs must be screened in one of the following ways: a. A parapet that is as tall as the tallest part of the equipment; b. A screen around the equipment that is as tall as the tallest part of the equipment; or c. The equipment is set back from roof edges 3 feet for each foot of height of the equipment.

(Ord. No. 1106, § 4(Exh. A), 10-10-2023)

Ask a question about Lancaster law

Corpus searches the Lancaster sections it holds and shows the ones that match, with their citations. Free, no sign-in.